Page 8
Operation
Ensure that the operator is suitably qualified to use a machine of this nature and that they have fully read
and understood this manual - they should be aware of all safety aspects relating to the safe use of the
machine.
It is advisable that all ‘first time’ operators practice using the machine in a clear safe area, with clean water
only prior to work in order to familiarise themselves with its operation.
AFTER APPROXIMATELY ONE HOUR OF WORK WITH A NEW MACHINE, ALL NUTS, BOLTS AND DRIVE BELTS
SHOULD BE CHECKED FOR TIGHTNESS AND ADJUSTED AS NECESSARY!
Control Module
ON/OFF:
Switches the control box on or off. When switched on, the applicator roller will run continuously.
APPLICATION RATE:
The desired spray rate is set using the up/down arrows, with the current output value
(between 0 & 100) displayed on the 3-digit display. For example, the machine will run for 50% of the time
when set to 50 on the control box.
RECOMMENDED START VALUE = 20%
PUMP RUN:
Switches the sequenced pump on or off so that chemical is applied to the applicator at the
application rate set.
PURGE:
This runs the pump continuously when pressed, ideal for clearing blockages, purging the system of
air or when flushing through with water after use.