Page 14
General Troubleshooting
Problem
Possible Causes
Remedies
Unit will not light up when on
button pressed
Low Supply Power
Charge Battery
Incorrect Polarity / poor
connection
Check connection
Shortage in wiring
Check wiring loom for damage
and repair / replace as required
Motor does not operate even
though control box is on
Poor connection between control
box and TF350
Check plug is clean and moisture
free
Shortage in wiring (may be
indicated by unit losing power when
run button pressed)
Check wiring for damage
Motor Fault
Replace motor, contact distributor
Counter does not operate
Poor connection
Check plug is clean and moisture
free
No signal (
Fault F1
)
Adjust or replace sensor (see
handbook)
Sensor fault
Replace sensor
No material is fed
Jammed slide plate
Check for blockages and remove
Hopper bridging
Agitate hopper contents
Drop size varies
Drop adjustment plate loose
Adjust and tighten hand screws
Feed leaking out from chute
Jammed slide plate
Check for blockages and remove
Slide plate
‘sticking’ (May
be ap-
parent on feeds with high molasses /
binding content
Clean slide plate area. A stronger
return spring can be provided if
required for very sticky feed.
Storage
For extended periods of storage, it is advisable that the machine be kept in a clean dry environment protected from
the elements to avoid risk of corrosion.
The machine should be thoroughly cleaned and lubricated prior to storage. At this point it is good practice to check
the machine for worn or damaged components - any parts that require replacing should be ordered and fitted at
the earliest opportunity so the machine is fully prepared for the next seasons work.