Chapin 6-9138 Скачать руководство пользователя страница 3

2E

Instruction Manual - English

Installation and Operation Precautions

1.

 

DO NOT

 subject the pump to pressures above 125 PSI (8.5 bars)

2.

 As long as there is inlet water pressure, the pump will not stop forward flow of water 

even if the motor is turned off. Be sure the system has positive means of shutting off 

water supply.

3.

 

DO NOT

 operate pump in an explosive environment. Arcing from the motor brushes, 

switch or excessive heat from an improperly cycled motor may cause an explosion.

4.

 

DO NOT

 locate the pump motor near combustible material. The surface temperature of 

the motor can exceed 250’ F (120° C).

5.

 

DO NOT

 pump gasoline, diesel fuel, petroleum products or other flammable liquids. 

The pump head materials and elestomers are designed 

FOR USE WITH WATER BASED 

PRODUCTS ONLY

.

6.

 Not all fluids/chemicals are compatible with this pump. Pump elastomers may fail and 

cause leaks if used incorrectly, left to sit in incompatable fluids.  

7. 

To avoid electrical shock, disconnect power before working on this pump. Always 

use caution In the case of pump failure, the housing and/or pump fluid may carry high 

voltage to components and connections that are normally safe to touch. There is always 

a possibility of electrical shock when working with and handling electrical components. If 

unsure, consult a licensed electrician. Always use a qualified electrician for hardwiring and 

completing electrical connections. Follow local and state electrical codes where applicable.

Installation & Operation

1.

 Water supply should be turned off or disconnected from source.

2.

 Trim flexible tubing to desired length for secure connection 

3.

 Insert tubing into the 90˚ or straight quick connect fittings provided. Use the 90˚ fitting 

if tubing crimps on entrance to, or exit from the pump.  Clamp hose to fitting ( clamps 

not included) and slide fitting onto quick attach brackets on the pump. Secure by sliding 

locking tabs in place.

4.

 Your Chapin pump has a standard electrical connection with in-line fuse protection for 

easy hook up with any 12v battery supply such as a graden tractor, ATV or UTV battery.  

5.

 Your Chapin pump is ready for use.

6.

 The pump will begin building pressure. Operating pressure will vary with flow rate, flow 

valve, feed-water pressure and line voltage. Check for fitting leaks. Run for approximately 

15 minutes. Note: further adjustments should not be necessary although it may take 

several days of operation before all the air has been purged and the system is stabilized.

(1) 90˚ Quick 

Attach Fitting

(2) Straight 

Quick 

Attach Fittings

Содержание 6-9138

Страница 1: ...4021 0549 U S A 1 800 950 4458 www chapinmfg com 2 5 GPM 12V DIAPHRAGM PUMP Model 6 9138 017633 R0421 Carefully Read These Instructions Before Use WARNING INSTRUCTION MANUAL DO NOT RETURN TO STORE Call 1 800 950 4458 www chapinmfg com See website for warranty detail ...

Страница 2: ...ign debris out of the system If a check valve is needed use valve rated with a cracking pressure of no more than 2 PSI 0 14 bar 4 Always install tubing to maintain a unincumbered path to avoid crimping Use 90 elbow fittings if necessary 5 Always mount pump before other components to avoid introducing particles to the water This will prevent possible pump damage or failure from foreign debris Elect...

Страница 3: ...o touch There is always a possibility of electrical shock when working with and handling electrical components If unsure consult a licensed electrician Always use a qualified electrician for hardwiring and completing electrical connections Follow local and state electrical codes where applicable Installation Operation 1 Water supply should be turned off or disconnected from source 2 Trim flexible ...

Страница 4: ...in 12V 2 5 GPM pump PROBLEM CHECK Pump won t start Correct voltage 10 and electrical connections Fuse or breaker Pressure switch operation Rectifer or motor for open or grounded circuit Locked drive assembly Correct voltage at switch Pump will not prime No discharge with motor running Debris in strainer Restriction kinks in inlet outlet tubes Debris swelling in inlet outlet valves Pump will not sh...

Страница 5: ... those who handle return shipments and our lab technicians that evaluate the isuues with your return Please call the Chapin International Inc before returning any product 1 800 950 4458 CAUTION DO NOT OPERATE PUMP IN AMBIENT FREEZING TEMPURATURES STORAGE Protect the pump from freezing during storage Fill pump system with RV antifreeze RV antifreeze is the preferable choice It is biodegradable and ...

Страница 6: ...50 4458 www chapinmfg com Modelo 6 9138 017633 R0421 Chapin International Inc P O Box 549 700 Ellicott St Batavia NY 14021 0549 U S A 1 800 950 4458 www chapinmfg com Lea estas instrucciones atentamente antes de utilizarlo ADVERTENCIA Visite el sitio web para conocer los detalles de la garantía ...

Страница 7: ... Si necesita una válvula de retención use una válvula con presión de apertura que no sea mayor a 2 PSI 0 14 bar 4 Siempre instale la tubería de modo que se mantenga una ruta despejada para evitar deformaciones Use codos de 90 si es necesario 5 Siempre monte la bomba antes de otros componentes para evitar introducir partículas al agua Así evitará posibles daños o fallas de la bomba debido a residuo...

Страница 8: ...e manera segura Siempre existe la posibilidad de una descarga eléctrica al trabajar con componentes eléctricos y al manipularlos Si tiene alguna duda consulte a un electricista autorizado Siempre contrate a un electricista calificado para cablear y hacer conexiones eléctricas Cumpla los códigos eléctricos estatales y locales que sean aplicables Instalación y operación 1 El suministro de agua debe ...

Страница 9: ...abeza de la bomba flojos Operaciones ajustes al interruptor de presión Fugas en la cabeza o interruptor de la bomba Tornillos sueltos en el interruptor o cabeza de la bomba Diafragma del interruptor roto o pellizcado Diafragma perforado si hay líquido presente Solución de problemas de su bomba Chapin de 12 V 2 5 GPM Manual de instrucciones Español Aproveche al máximo su bomba Chapin Revise el sist...

Страница 10: ...ciben las devoluciones y a nuestros técnicos de laboratorio que evalúen los problemas de su equipo devuelto Llame a Chapin International Inc antes de devolver cualquier producto 1 800 950 4458 PRECAUCIÓN NO HAGA FUNCIONAR LA BOMBA A TEMPERATURAS AMBIENTE DE CONGELAMIENTO ALMACENAMIENTO Proteja la bomba contra el congelamiento mientras está almacenada Llene el sistema de la bomba con anticongelante...

Страница 11: ... 4458 www chapinmfg com Modèle 6 9138 017633 R0421 Chapin International Inc P O Box 549 700 Ellicott St Batavia NY 14021 0549 U S A 1 800 950 4458 www chapinmfg com Lisez attentivement ces instructions avant l utilisation AVERTISSEMENT Veuillez consulter le site Web pour en savoir plus sur la garantie ...

Страница 12: ... un clapet dont la pression de fissuration ne dépasse pas 2 PSI 0 14 bar 4 Installez toujours la tubulure pour maintenir un chemin non encombré afin d éviter le sertissage Utilisez des raccords coudés de 27 m 90 pi si nécessaire 5 Montez toujours la pompe avant les autres composants pour éviter d introduire des particules dans l eau Cela évitera d éventuels dommages à la pompe ou une défaillance p...

Страница 13: ...oucher Il existe toujours une possibilité de décharge électrique lors de travaux ou de la manipulation de composants électriques En cas de doute consultez un électricien autorisé Utilisez toujours un électricien qualifié pour le câblage et l achèvement des connexions électriques Respectez les codes nationaux et locaux de l électricité le cas échéant Installation et fonctionnement 1 L alimentation ...

Страница 14: ...traînement ou les vis de la tête de pompe Les opérations réglages de l interrupteur de pression Fuites de la tête de pompe ou de l interrupteur Desserrer les vis de l interrupteur ou de la tête de pompe La membrane d interrupteur est rompue ou pincée La membrane percée si du fluide est présent Dépannage de votre pompe Chapin de 12 V et 9 5 L MIN 2 5 GAL M Tirez le meilleur parti de votre pompe Cha...

Страница 15: ...er tous ceux qui gèrent les retours et nos techniciens de laboratoire qui évaluent les problèmes lors de votre retour Veuillez appeler Chapin International Inc avant de retourner tout produit 1 800 950 4458 AVERTISSEMENT NE PAS FAIRE FONCTIONNER LA POMPE DANS LES TEMPÉRATURES AMBIANTES AYANT ATTEINT LE NIVEAU DE CONGÉLATION ENTREPOSAGE Protégez la pompe du gel pendant le stockage Remplissez le sys...

Страница 16: ...Chapin International Inc P O Box 549 700 Ellicot St Batavia NY 14021 0549 USA 1 800 950 4458 www chapinmfg com ...

Отзывы: