Channel Safety Systems Zerio Plus Скачать руководство пользователя страница 8

8  |   revision 013-1   

 

 

www.channelsafety.co.uk   



0845 884 7000     @ [email protected]

Sample System Architecture

Survey Kit

PRODUCT CODE

DESCRIPTION

F/EDA-Z5000

Zerio Plus survey kit

Designed to enable the user to conduct a thorough survey for radio/ 
wireless fi re alarm system signal.

The frequency used is 868MHz.  

Please Note: If required we can also off er an installation and commissioning 
service for this equipment.  For more details contact our Technical Services 
department on 0845 884 7000 or email [email protected]

Case Contents

• 

1 x Survey Detector (SSD)

• 

1 x Survey Transmitter (SST)

• 

1 x Antenna

• 

1 x Extension Poles (x4)

GET INTERACTIVE

Scan the code for further information and technical documents on the Zerio Plus range

www.channelsafety.co.uk/zerio-plus/

Please note the Radio Booster Display Panel will be available from March 2014

Control 
Panel

Display Panel

Radio Booster 
Panel

Radio Booster 
Panel

Wired transceiver

Sensor

Sounder

Break glass unit

Содержание Zerio Plus

Страница 1: ...Wireless system from Channel Safety Systems Zerio Plus...

Страница 2: ...acement battery for all devices SPECIFICATIONS Maximum Number of Zones EDA Z5008 8 EDA Z5020 20 Maximum Number of Devices 240 for larger premises upto four systems can be linked together Max no of rad...

Страница 3: ...le wireless smoke detector and combined sounder The smoke chamber and internal workings of the EDA R6000 are housed in an attractive low profile exterior The unit is completely self contained and requ...

Страница 4: ...detector element and internal workings are housed in an attractive low profile exterior The unit is completely self contained and requires no external cabling and is powered by a lithium battery assem...

Страница 5: ...Battery x3 EDA Q690 Weight 440g Visual Indicators The EDA A6000 Zerio Plus Wireless Wall Sounder is a wall mounted and designed specifically to be used with the Zerio Plus range of wireless fire alar...

Страница 6: ...on Transmitter Frequency 868 MHz Transmission Type Narrow band FM Channels 13 available Audible Warning Sounds in alarm and test mode Indications Alarm high intensity clear LED Fault red solid red fla...

Страница 7: ...vailable Audible Warning Sounds in alarm and test mode Battery 1 x 12V 7AH for booster only Booster Panel and Antennas PRODUCT CODE DESCRIPTION F EDA Z6000 Zerio Plus booster panel requires 240V suppl...

Страница 8: ...oning service for this equipment For more details contact our Technical Services department on 0845 884 7000 or email service channelsafety co uk Case Contents 1 x Survey Detector SSD 1 x Survey Trans...

Отзывы: