Channel Master 1.2m Rx/Tx ANTENNA SYSTEM Скачать руководство пользователя страница 6

GROUND POLE INSTALLATION

MIN.

DIA.

d

d

MIN.

DIA.

ANT

3.00" O.D.

3.00" O.D.

40"

C

L

72"

39.9"

39.9"

increased,

72"

40.9"

50" depth may be

will increase

length of rebar

concrete and

accordingly.

2"

2"

50"

NOTE:

#3 REBAR x DIA. OF PIER, INSERT

FROST LINE

#3 REBAR x

DIA. OF PIER

INSERT THRU  HOLE

IN TUBE & CENTER

AT 90

°

 APART

(SEE NOTE)

(4)#3x24"MIN.

BELOW

THRU HOLE IN TUBE & CENTER

1" to 2"

WATER RUN OFF

GRADE

SLOPE FOR

BELOW

FROST LINE

APPROX.

1" to 2"

SLOPE FOR

(SEE

NOTE)

GRADE

WATER RUN OFF

GROUND

ANT

WIND VEL.

DIM “d”

CONC VOL.

DIM “d”

CONC VOL.

DIM “d’

CONC VOL. DIM “d” CONC VOL.  POLE 

80 MPH

8”

1.3 

13”

3.4 

8”

1.6

10”

2.5

“A”

90 MPH

10”

2.0 

16”

5.1 

8”

1.6

12”

3.6

1.2M

100 MPH

12”

2.9 

18”

6.5 

8”

1.6

13”

4.2

“A” or

LFL

110 MPH

14”

3.9 

21”

8.8 

10”

2.5

16”

6.4

“B”

125 MPH

17”

5.8 

24”

11.5 

12”

3.6

19”

9.0

“B” Only

POLE SPECIFICATIONS:

Ground Pole “A” = 3.00 O.D. x 9 G.A. (.148 Wall) x 72” Steel 
Ground Pole “B” = 3.00 O.D. x .250 Wall x 72” Steel ASTM 120 Mech Tubing

NOTE:
Pole “A” is supplied from factory powder painted and with hole for #3 rebar and grounding screw.
Pole “B” not supplied and must be field drilled 

⁵⁄₈

” dia. for #3 rebar and drilled .218 for 

¹⁄₄

-20 self tapping

grounding screw and galvanized  or painted for protection.

1 - Pole and foundation design based on the following criteria:

a) Uniform building code exposure B or C and 1.5 stability factor.
b) Vertical soil pressure of 2000 pounds per square foot.
c) Lateral soil pressure of 400 pounds per square foot.
d) Concrete compressive strength of 2500 pounds per square inch in 28 days.

2 - CAUTION - The foundation design shown does not represent an appropriate design for any specific locality since soil conditions vary

and may not meet design criteria given in Note 1. You should consult a local professional engineer to determine your soil conditions
and appropriate foundation.

Exposure “B”

Exposure “C”

Exposure “B”

Exposure “C”

PIER FOUNDATIONS

DEEP FROST LINE FOUNDATIONS

Bubble
Level

Ground Pole
Must Be
Vertical In
All Directions
Within .19 Inches
At Top (0.3˚)

5

Содержание 1.2m Rx/Tx ANTENNA SYSTEM

Страница 1: ... in U S A 8000636 6 99 Rev A World Headquarters USA 1315 Industrial Park Drive Smithfield NC 27577 USA Telephone 919 989 2205 Fax 919 989 2200 International GmbH Julius Moser Str 13 75179 Pforzheim Germany Telephone 49 0 7231 14557 0 Fax 49 0 7231 14557 10 Europe UK Croft Head Road Blackburn England BB1 5UE Telephone 44 0 1254 680444 Fax 44 0 1254 672299 ...

Страница 2: ...cordance with the instructions furnished by CHANNEL MASTER Claimants under this Warranty shall present their claims along with the defective equipment to CHANNEL MASTER immediately upon failure Non compliance with any part of this claim procedure may invalidate this warranty in whole or in part THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER AGREEMENTS AND WARRANTIES ANY IMPLIED WARRANTY OF MERCHA...

Страница 3: ...2 DATE DESCRIPTION REV 11 97 ECN 9000000 Rel 5 99 ECN 9004530 A ...

Страница 4: ...ey will remove it safely 7 Make sure that the mast assembly is properly grounded WARNING Assembling dish antennas on windy days can be dangerous Because of the antenna surface even slight winds create strong forces For example a 1 0m antenna facing a wind of 32 km h 20 mph can undergo forces of 269 N 60 lbs Be prepared to safely handle these forces at unexpected moments Do not attempt to assemble ...

Страница 5: ...he satellites A site with a clear unobstructed view is pre ferred Also consider obstruction that may occur in the future such as the growth of trees Your antenna site must be selected in advance so that you will be able to receive the strongest signal available To avoid microwave interference obstructions etc conduct an on site survey with a portable antenna As with any other type of construction ...

Страница 6: ... ASTM 120 Mech Tubing NOTE Pole A is supplied from factory powder painted and with hole for 3 rebar and grounding screw Pole B not supplied and must be field drilled dia for 3 rebar and drilled 218 for 20 self tapping grounding screw and galvanized or painted for protection 1 Pole and foundation design based on the following criteria a Uniform building code exposure B or C and 1 5 stability factor...

Страница 7: ...Feed Leg and secure with Lock Washer and Hex Nut NOTE Bottom Feed Support Leg is the shorter one and has two holes on one end Attach left and right Feed Legs to reflector using M6 x 16mm Hex Bolts Flat Washers Lock Washer and Hex Nuts Note Long formed end attaches to reflector Assemble Feed Support Block supplied with Feed Package to Feed Support Legs using M6 x 16mm Hex Bolts Lock Washers and Hex...

Страница 8: ... DIA TWIST DRILL FIG 2 0 Typical Electrical Grounding for Antenna Ground Pole NOTE All installations to conform to latest issue of National Electrical Code Ground antenna mount assembly and feed cables in accordance with current National Electrical Code and local electrical codes Figure 2 0 and 2 1 illustrates typical grounding methods for the ground pole and feed cables Clamps that provide a soli...

Страница 9: ...sing at the desired elevation reading This will be an approximate setting Optimum setting achieved when fine tuning AZIMUTH Use Chart 3 and determine your azimuth setting Values in chart must be adjusted for magnetic deviation for your location for correct compass reading Rotate reflector and mount pointing it to the correct compass reading Slowly sweep the antenna in azimuth until signal is found...

Страница 10: ...NA SITE EAST OF SATELLITE LONGITUDE EARTH STATION LATITUDE IN DEGREES NORTH OR SOUTH OF EQUATOR POLARIZATION OR SEE ILLUSTRATION L IS THE DIFFERENCE BETWEEN THE EARTH STATION ANTENNA SITE LONGITUDE AND THE SATELLITE LONGITUDE POLARIZATION CHART CHART 1 75 60 40 30 20 15 10 5 Feed Rotation Facing Antenna For Polarization Rotate CCW Counter Clockwise For Polarization Rotate CW Clockwise 9 ...

Страница 11: ...UATOR ELEVATION IN DEGREES L IS THE DIFFERENCE BETWEEN THE EARTH STATION ANTENNA SITE LONGITUDE AND THE SATELLITE LONGITUDE ELEVATION CHART 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 50 125 120 115 110 105 100 95 90 85 80 75 70 65 50 47 5 45 42 5 40 37 5 35 32 5 30 27 5 25 47 5 45 42 5 40 37 5 35 32 5 30 27 5 25 ...

Страница 12: ...ION IS EAST OF SATELLITE EARTH STATION ANTENNA LATITUDE IN DEGREES NORTH OR SOUTH OF EQUATOR EARTH STATION ANTENNA AZIMUTH IN DEGREES L IS THE DIFFERENCE BETWEEN THE EARTH STATION ANTENNA SITE LONGITUDE AND THE SATELLITE LONGITUDE AZIMUTH CHART CHART 3 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 NORTHERN HEMISPHERE SOUTHERN HEMISPHERE WEST EAST WEST EAST 0 10 20 30 40 50 60 70 80 90 360 350 340 ...

Страница 13: ...rm building code Height and are NOT incl ded S FT LBS N m APPENDIX A 1 2m ANTENNA SURVIVAL WINDLOADS AT 125 MPH VELOCITY 70 60 50 40 30 MECHANICAL 20 10 0 87 77 67 57 47 515 686 822 943 1071 37 27 17 BEAM 1182 1217 1285 H F 762 985 943 857 711 497 257 35 F V O T M F V O M 178 232 299 357 421 3 214 2 802 2 338 2 096 3 650 464 488 500 T M 4 029 4 380 4 148 O M OVERTURNING MOMENT VERTICAL FORCE TORSI...

Страница 14: ... 3 ITEM DESCRIPTION QTY 1 BOLT PLOW SPECIAL M8 x 91mm 4 2 REFLECTOR 1 2m LFL 1 3 CAP VINYL 1 4 WASHER LOCK SS 5 6 MOUNT ASSEMBLY 1 2m LFL LT DTY 1 7 BOLT HEX HD M8 x 20mm 1 8 NUT HEX SS M8 1 10 BOLT HEX HD M6 x 16mm 6 11 WASHER LOCK SS 6 12 FEED SUPPORT TUBE BOTTOM 1 13 NUT HEX M6 2 14 FEED SUPPORT TUBE SIDE 2 ...

Страница 15: ...SORTER BOLT PLOW SPECIAL M8 x 91MM Hardware illustrations are true size Place actual hardware on top of illustration to identify ITEM 10 M6 x 16MM HEX HD CAP SCREW SS ITEM 1 M8 x 20MM ITEM 7 HEX HD CAP SCREW SS ...

Отзывы: