Changzhou Gardensun Furnace HSS-A-GH Скачать руководство пользователя страница 12

11

Troubleshooting

If the problem is:

And this condition exists:

Then do this

Pilot won’t light

Cylinder valve is closed

Open valve

Blockage in orifice or pilot tube

Clean or replace orifice or pilot tube

Air in gas line

Open gas line and bleed it (pressing control

knob in) for not more than 1 - 2 minutes or

until

you smell gas

Low gas pressure with cylinder valve

fully open

Turn cylinder valve OFF and replace cylinder

Note:

Heater

operates

at

reduced efficiency below 40ºF

(5ºC)

Igniter fails

Use match to light pilot; obtain new igniter and

replace

Pilot won’t stay lit

Dirt built up around pilot

Clean dirt from around pilot

Connection between gas valve and

pilot assembly is loose

Tighten connection and perform leak check

Thermocouple is not operating correctly

Replace thermocouple

Burner won’t light

Gas pressure is low

Turn cylinder valve OFF and replace cylinder

Blockage in orifice

Clear blockage

Control knob is not in ON position

Turn control knob to ON

Burner flame is low

Gas pressure is low

Turn cylinder valve OFF and replace cylinder

Outdoor temperature is less than 40ºF

and tank is less than 1/4 full

Use a full cylinder

Supply hose is bent or kinked

Straighten hose

Control knob fully ON

Check burner and orifices for blockage

Carbon build-up

Dirt or film on reflector and burner screen

Clean reflector and burner screen

Thick black smoke

Blockage in burner

Remove blockage and clean burner inside and

outside

Maintenance

WARNING

FOR YOUR SAFETY:

• Do NOT touch or move heater for at least 45 minutes

after use.

• Reflector is hot to the touch.

• Allow reflector to cool before touching.

To enjoy years of outstanding performance from your

heater, make sure you perform the following maintenance

activities on a regular basis:

Air flow must be unobstructed. Keep controls, burner,

and circulating air passageways clean. Signs of possible

blockage include:

a. Keeping the appliance area clear and free from combustible 

   materials , gasoline and other flammable vapors and liquids.

b. Not obstructing the flow of combustion and ventilation air.

Keep exterior surfaces clean.

Use warm soapy water for cleaning. Never use

flammable or corrosive cleaning agents. 

While cleaning your unit, be sure to keep the area around the

burner and pilot assembly dry at all times. Do not submerge the

control valve assembly. If the gas control is submerged in water,

do NOT use it. It must be replaced.

c.Keeping the ventilation opening(s) of the cylinder enclosure

   free and clear from debris.

Содержание HSS-A-GH

Страница 1: ...SKU NUMBER 70005001 IMPORTANT Read this manual carefully before assembling using or servicing this heater Keep this manual for future reference ANSI Z83 26 2007 CSA 2 37 2007 Gas Fired Outdoor Infrar...

Страница 2: ...mechanical or fueled equipment 1 DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates an imminently hazardou...

Страница 3: ...I Z223 1 In Canada installation must conform to local codes If no local codes exist follow the current National standards of CANADA CAN CGA B 149 2 DANGER CARBON MONOXIDE HAZARD This heater is a combu...

Страница 4: ...sources or where temperatures exceed 120 degrees F 49 C Propane vapors are heavier than air and canaccumulate in low places If you smell gas leave the area immediately Never install or remove propane...

Страница 5: ...1 Attach Support Brackets to Base Attach three Support Brackets loosely to Base with three medium bolts downward through Support Brackets into the Base 3 Req d Medium Bolts Installation process Revers...

Страница 6: ...Load Cylinder Housing onto Post Load Cylinder Housing onto Post Slide Cylinder Housing down Step 4 Attach Reflector Studs to Screen Cover Insert 3 Reflector Studs 3 Flat Washers Tighten studs securely...

Страница 7: ...each screw prior to further assembly and retighten after sections are aligned Slide two Reflector Panels together Insert one Small Screw Slide one Small Flat Washer over threaded end of screw and scre...

Страница 8: ...10 W C is required for purpose of input adjustment The minimum hourly of 17000 Btu is required input rating for a heater for automatic operation at ratings less than full input rating You must provide...

Страница 9: ...ce of purchase If leak is at Regulator Cylinder Valve connection disconnect reconnect and perform another leak check If you continue to see bubbles after several attempts cylinder valve is defective a...

Страница 10: ...s Pilot must be lit before Main Burner can be started 5 Push and release the igniter button until pilot flame is visible through Viewing Hole 6 Once the pilot is lit continue to depress the control Kn...

Страница 11: ...and continue to turn it clockwise to OFF Turn Cylinder Valve clockwise to OFF and disconnect Regulator when heater is not in use Note After use some discoloration of the emitter screen is normal Oper...

Страница 12: ...inder Supply hose is bent or kinked Straighten hose Control knob fully ON Check burner and orifices for blockage Carbon build up Dirt or film on reflector and burner screen Clean reflector and burner...

Страница 13: ...The manufacturer warrants to the original consumer purchaser only that this product Model HSS A GH shall be free from defects in workmanship and materials after correct assembly and under normal and...

Страница 14: ...SCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES Repair or replacement of defective parts is your exclusive remedy under the terms of this limited warranty Manufacturer will not be responsible fo...