FLW-717C Product Manual
Shenzhen City Chang Rui Technology Co., Ltd
The system is provided with "Super User" operating authority
,
input “123321” to open addition
function.
Temperature fan control, the default is "Auto" mode:> 45 degrees open, <40 degrees off
;
The other
is normally open, normally closed, and other modes can be set manually for customers to choose.
There are a number of test items set about 717C LVDS signal output box (convenient point screen
test) and bake mode switch, pager mode must be the case in the absence of a signal can be opened next
ah, function: red, green, blue , white, black and other colors flicker, no it can be closed.