Attack

This is a continuous control and is used to set the speed at 
which compression is onset.

Historical note:

  EMI limiters including the: RS114 tube lim-

iter, RS124 Compressor, RS168 Zener prototype, TG12345 
recording console limiters, and TG12410 transfer desk limit-
ers had fixed attack times.

Release

This is a continuous control and is used to set the recovery 
time from compressed conditions to the inactive state gain 
level. 

Historical note:

  EMI limiters including the: RS114 tube lim-

iter, RS124 Compressor, RS168 Zener prototype, TG12345 
recording console limiters, and TG12410 transfer desk limit-
ers had six fixed recovery (release) times.

 

Hold

The 

Hold

 control is continuous and used to set the desired 

degree of compression, a setting of 

0

 is least and 

-10

 is maxi-

mum potential reduction.

Note:

  The 

Hold

 control works independently of level ap-

plied to the compressor, i.e. regardless of where the meter 
needle is placed, the hotter the input signal into the TG1 
Opto is, the greater the rate of compression be. 

Tip:

  To cope with inconsistent peak level programme, set 

the 

Hold

 control fully anticlockwise (

-10

), and send lower lev-

el signal into the compressor, gradually increase the source 
until the desired amount of compression is achieved; adjust 
the TG1 Opto 

Output

 control — described in the next sec-

tion — to make up any gain lost.

Output

Provision is made for makeup gain by means of the compres-
sor’s 

Output

 control. This control is continuous and used to 

return compressed programme to level; anticlockwise rota-
tion is less makeup gain. 

Note:

  The more compressed programme is, the louder the 

processed material may appear, thus necessitating reduction 
of the compressor’s 

Output 

control.

ATTACK

ROUNDED

1

2

3

4

5

6

7

8

9

10

11

+ 1 2

+ 8

+ 4

0

+ 1 6

Gain

Reduction

BYPASS

SHARP

RELEASE

ROUNDED

IN

1

2

3

4

5

6

7

8

9

10

11

1

11

KNEE

SHARP

ATTACK

HOLD

ROUNDED

1

2

3

4

5

6

7

8

9

10

11

-10

-9

-8

-7

-6

-5

-4

-3

-2

-1

0

OPTO

KNEE

+ 1 2

+ 8

+ 4

0

+ 1 6

Gain

Reduction

BYPASS

SHARP

ROUNDED

OUTPUT

IN

1

2

3

4

5

6

7

8

9

10

11

KNEE

Содержание TG MICROPHONE CASSETTE

Страница 1: ...BASS EQ IN OUTPUT 5 6 4 3 2 1 0 7 8 9 10 IN 8 6 4 2 0 2 4 10 6 8 10 8 6 4 2 0 2 4 10 6 8 10 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 10 9 8 7 6 5 4 3 2 1 0 COARSE GAIN F...

Страница 2: ...5 Audio Input Output Connections 5 Link 5 TG2 6 Coarse Gain 6 Fine Gain 6 Rumble Filter 6 Utility Cluster 7 CURVE BENDER 8 Treble 8 Bass 8 Presence 8 EQ In 8 Output 8 TG1 OPTO 9 Important Notes on Us...

Страница 3: ...s Central Research Laboratories teams the EMI TG12345 Mark I desk ushered in a sea of change in sound and flexibility at Abbey Road Studios Installed in Abbey Road s Studio Two in November 1968 and m...

Страница 4: ...vide protection for shipment and storage Please retain the container and associated materials for future use Note PSU rigid foam surrounds and sheets are not included for equipment shipped without a p...

Страница 5: ...Microphone Cassette exists two sets of male and female XLR connectors one pair for the Pre Amp EQ section and the other for independent ac cess of the Compressor All audio XLR connectors are wired pi...

Страница 6: ...e on historic REDD 51 valve consoles and activated via a plug in jumper The Rumble Filter was fixed at 30 Hz and was unique in its circuit design TG2 The TG2 section of the TG Microphone Cassette is a...

Страница 7: ...the rear of the unit Tip Sending line level source into the Pre Amp EQ section is a great way to further process material by adding the rich harmonic texture available from this historic circuit use...

Страница 8: ...was a rotary switch EQ In The toggle switch labeled EQ IN when positioned downward inserts the Curve Bender into the audio path conversely in the upward position the equalizer section is bypassed Outp...

Страница 9: ...1 Opto compressor is understanding the Gain Reduction meter and Hold control without signal present The meter scale range begins below 0 and extends to 20 at the end of the red region The degree of co...

Страница 10: ...regardless of where the meter needle is placed the hotter the input signal into the TG1 Opto is the greater the rate of compression be Tip To cope with inconsistent peak level programme set the Hold...

Страница 11: ...ypes Sharp and Rounded Sharp knee Sharp is equivalent to limit mode on the TG1 and Zener Lim iters and is considered hard When the Knee switch is set to Sharp compression will be full ratio Tip Sharp...

Страница 12: ...products purchased outside of the United States is provided by local or regional authorized Chandler Limited distributors To obtain service or repairs please contact your local dealer or regional dis...

Страница 13: ...States If you live in the United States and your product was purchased through a U S Dealer please contact your dealer OR call 319 885 4200 or e mail support chandlerlimited com WhatYou Must Do for Wa...

Страница 14: ...STATE STATUTE LIMITATION OF LIABILITY THE LIABILITY OF CHANDLER LIMITED IF ANY AND PURCHASER S SOLE AND EXCLUSIVE REMEDY FOR DAM AGES FOR ANY CLAIM OF ANY KIND WHATSOEVER REGARDLESS OF THE LEGAL THEO...

Отзывы: