![Chandler Limited EMI TG12413 LIMITER Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/chandler-limited/emi-tg12413-limiter/emi-tg12413-limiter_user-manual_2589473013.webp)
Page 13
Recovery
This switch is marked 1-6 because the release times change when switching between
compress and limit. #1 being the fastest through to #6 being the slowest. This control is
important for varying the sound of the unit. As you slow compression it greatly affects the
amount and sound of the gain reduction. Listen closely to the changes it makes.
Fig. 10 — 1969 Module
Fig. 11 — 2005 Module
Recovery Times by Mode (in seconds)
Settings
1
2
3
4
5
6
Limit Mode
0.05
0.1
0.25
0.5
1
2
Compress Mode
0.25
0.5
1.20
2.5
5
10
Attack Times
Limit Mode
8 ms Charging Time
Compress Mode
47 ms Charging Time