28
29
Troubleshooting
The following troubleshooting guide can help identify a problem and provide a solution.
Inspect your waste handling system before you contact an authorized service representative.
System will not turn ON.
Main Power Supply OFF
Remote Control Cabinet 3A
push button breaker tripped.
Remote control cabinet Main Circuit
Breaker Switch OFF.
Safety Switch not closed or
defective.
Start/Stop Station switch not operated
or defective.
Main water supply valve is closed.
Remote control cabinet Main Circuit
Breaker Switch OFF.
Pulper water level pressure switch
mis-adjusted or defective.
Water solenoid valve defective.
Drain valve or water extractor
drain/overflow open.
Pulper water level pressure switch
mis-adjusted or defective.
Pressure switch tubing or air
snubber is clogged or broken.
Water solenoid valve defective.
Water extractor screen clogged
and/or auger brush defective.
Metal object in tank.
Cutting blades hitting cutting blocks.
Waste input lacks paper
Extractor drain/overflow restricted.
Compression Cone mis-adjusted.
Remote Control Cabinet Main Circuit
Breaker Switch has tripped. Handle
is in the TRIP position.
Main Power Supply to system OFF.
Problem
Cause(s)
Solution(s)
Turn on or reset breaker.
Push to reset 3A breaker
Rotate Handle to ON Position.
Check/replace pulper and/or
water extractor safety switch.
Push Start push button to run.
Open valve.
Adjust or replace switch.
Clean or replace snubber/tubing.
Repair or replace solenoid valve.
Remove object.
Contact service agent to adjust.
Close drain valve, rotate drain/overflow
handle to closed position.
Feed cardboard into pulper to thicken slurry.
Shut down system and contact service agent.
No fill water to pulper.
Rotate Handle to ON Position.
Pulper fills constantly.
Adjust or replace switch.
Repair or replace solenoid valve.
Clean extractor screen and/or
contact service agent.
Banging noise coming from pulper.
Pulp discharge is too wet.
Check drain/overflow in water extractor.
System shuts down unexpectedly.
Turn handle CCW to RESET then CW to
OFF and contact service agent.
Check Main Power Supply Breaker.
Содержание P5-24
Страница 9: ...Introduction Introduction 1 ...
Страница 17: ...9 Installation Installation ...
Страница 31: ...23 Pulper Water Extractor Operation Operation ...
Страница 33: ...25 Cleaning and Maintenance Pulper Water Extractor Cleaning and Maintenance ...
Страница 38: ...30 Blank Page This Page Left Intentionally Left Blank ...
Страница 42: ...34 Pulper Assembly Inner View 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 8 8 27 25 ...
Страница 56: ...48 Recirculating Pump Assembly Water Extractor Pulper 1 18 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2 8 7 12 12 ...
Страница 62: ...54 Deodorizer Pump Assembly Pulper Water Extractor 3 4 5 7 15 14 6 10 9 12 11 1 8 17 2 16 13 19 18 ...
Страница 64: ...56 Feed Trough Gaskets Pulper 1 3 4 4 5 2 Feed trough supplied by others ...
Страница 69: ...61 Electrical Schematic Electrical Schematic Remote Control Cabinet Component Selection Chart ...
Страница 70: ...62 Blank Page This Page Intentionally Left Blank ...