![Champion EUCCW4 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/champion/euccw4/euccw4_specifications_2588515005.webp)
1'-10"
2'-1"
13'-4" CL-CL
5'-8"
4'
4'
4"
5-1/2"
1-5/8"
38"
Plumbing
Clearance
12" [305]
100" [2540]
Door
Removal
Doors Up
95" [2413]
29" [737]
Clear
OVERALL LENGTH “C”
CL
CL
“A”
LOAD
8' [2438]
WASH/RINSE
“B”
UNLOAD
19" [483]
Clear
62" [1575]
Machine
Height
37-1/4"
2'
2'-6"
39" [991]
18-5/8"
[473]
12" [305]
4' [1219]
[4064]
[1727]
[559]
[946]
[762]
[102]
[965]
[41]
[140]
[635]
6" [152]
6-1/4" [159]
7" [178]
7" [178]
4" [102]
[610]
[1219]
[1219]
10-1/2" [266]
36" [914]
Start/Stop
1/2 HP
Plumbing
Clearance
HP
0.2
HP
3
HP
3
3
4A
1
2
4B
HP
1
2
4B
4A
1
3
POWER
RINSE
WASH
PREWASH
FINAL
RINSE
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Upright 29” Conveyor
Dual Rinse
Dishwashing Machine
EUCCW SERIES
EUCCW8
MOdULAR SECTIONS: Right to Left Operation
Notes:
Load Section (A)Standard 5 ft ,
contains 30” Prewash.
Prewash also available in
a 48” HD section.
Non-standard load section
available in 12” increments.
Minimum load length 5ft
(includes 30” prewash).
Unload Section (B)
Standard 5 ft contains 24” Aux.
Rinse and 36” belt, available in
12” increments.
Built in electric booster requires
a 5 ft minimum unload.
Built in steam booster requires
a minimum 6 ft unload.
Blow dryer section adds 4ft to
overall length of machine.
Machine Only - Electric Heat
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3
183
250
250
240/60/3
158
200
200
480/60/3
80
100
100
70°F/39°C Rise - 32kW Electric Built-in Booster
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3
89
125
125
240/60/3
77
100
100
480/60/3
39
50
50
40°F/22°C Rise – 18kW Electric Built-in Booster
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3
50
70
70
240/60/3
43
60
60
480/60/3
22
30
30
Machine-steam
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3
29
40
40
240/60/3
26
35
35
480/60/3
14
20
20
TABLE B - Booster Connection
TABLE A - Machine Connection
Dimensions shown in inches and [millimeters]