![Champion EUCCW4 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/champion/euccw4/euccw4_specifications_2588515003.webp)
1'-10"
[559]
9'-4" CL-CL
[2845]
5'-8"
[1727]
12" [305]
Plumbing
Clearance
100" [2540]
Door
Removal
95" [2413]
Doors Up
29" [737]
Clearance
OVERALL LENGTH "C"
CL
CL
"A"
LOAD
"B"
UNLOAD
19" [483]
Clear
62" [1575]
Machine Height
2'-6"
[762]
39" [991]
12" [305]
4' [1219]
6-1/4" [159]
6" [152]
7" [178]
7" [178]
4" [102]
4" [102]
36" [914]
2'
[610]
38"
[965]
1-5/8" [41]
10-1/2" [266]
2'-1"
[635]
18-5/8"
[473]
5-1/2"
[140]
37-1/4"
[946]
4' [1219]
WASH
2
2
4A
3
1
4B
4B
4A
1
3
Start/Stop
HP
3
1
HP
HP
0.2
1/2 HP
Plumbing
Clearance
WASH
PREWASH
FINAL
RINSE
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Upright 29” Conveyor
Dual Rinse
Dishwashing Machine
EUCCW SERIES
EUCCW4
MOdULAR SECTIONS: Right to Left Operation
Notes:
Load Section (A)Standard 5 ft ,
contains 30” Prewash.
Prewash also available
in a 48” HD section.
Non-standard load section
available in 12” increments.
Minimum load length 5ft
(includes 30” prewash).
Unload Section (B) Standard 5 ft
contains 24” Aux. Rinse and 36”
belt, available in 12” increments.
Built in electric booster
requires a 5 ft minimum unload.
Built in steam booster requires
a minimum 6 ft unload.
Blow dryer section adds 4ft to
overall length of machine.
TABLE B - Booster Connection
Machine Only - Electric Heat
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3
119
150
150
240/60/3
102
150
150
480/60/3
52
70
70
TABLE A - Machine Connection
Contact Factory for additional voltages.
70°F/39°C Rise - 25kW Electric Built-in Booster
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3
70
90
90
240/60/3
60
80
80
480/60/3
30
40
40
40°F/22°C Rise – 15 kW Electric Built-in Booster
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3
42
60
60
240/60/3
36
45
45
480/60/3
18
25
25
Machine-steam
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3
21
25
25
240/60/3
18
25
25
480/60/3
10
15
15
Dimensions shown in inches and [millimeters]