10
Cleaning
Cleaning
Front Cover
Top Cover
Access Cover
Condenser Coil
1.
Open the top cover over of the HRU.
2.
Remove the front cover of the unit by sliding it up.
3.
Remove the front access cover which is retained by three knurled thumbscrews.
4.
Flush the top of the condenser coil with fresh water.
5.
Do not wipe nor brush the coil fins.
6.
Flush the underside below the condenser coil with fresh water.
7.
Leave the HRU covers off overnight to allow the inside of the unit to air dry.
8.
Reassemble in reverse order at the beginning of the day.
Refer to the illustration below.
CAUTION:
Do not place objects on top of the condenser coil nor with the cleaning
devices. Avoid the use of cleansers or other detergents to prevent
damage to the top of the coil
Monthly Cleaning Schedule:
1.
Inspect the interior unit for
accumulated debris.
2.
Wipe the exterior of the unit
with a soft cloth and mild
detergent.
3.
DO NOT HOSE THE
EXTERIOR OF THE UNIT
WITH WATER.
Daily Cleaning Schedule:
1.
Contact an authorized
service agent to perform
general maintenance and
major cleaning.
Annual Cleaning Schedule:
Содержание Eseries HRU
Страница 10: ...4 Blank Page This Page Intentionally Left Blank ...
Страница 22: ...16 Control Cabinet Terminal Block Prior to S N J11022850 9 1 4 4 3 2 2 7 8 6 5 ...
Страница 26: ...20 Control Cabinet Terminal Block Beginning with S N J11022850 and above 9 1 4 3 7 8 6 5 4 5 2 ...
Страница 32: ...26 HRU Steam Booster Assembly 9 12 2 6 7 5 5 8 10 11 1 3 6 8 4 2 1 ...
Страница 34: ...28 HRU Steam Booster Piping ...
Страница 36: ...30 Blank Page This Page Intentionally Left Blank ...
Страница 38: ...32 Blank Page This Page Intentionally Left Blank ...
Страница 40: ...34 Operation Logic Diagram HRU Logic Diagram v 8410 ...
Страница 41: ...35 Electrical Schematic ...
Страница 42: ...36 Blank Page This Page Intentionally Left Blank ...