background image

3

4

SAFETy RULES

SAFETy RULES

Improper treatment or use of the generator can 
damage it, shorten its life and void your warranty.

Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture, 
dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and 
disconnect them from the generator.
DO NOT use the generator if:

 

– Electrical output is lost

 

– Equipment sparks, smokes or emits flames

 

– Equipment vibrates excessively

CAUTION

Rapid retraction of the starter cord will pull hand and 
arm towards the engine faster than you can let go. 
Unintentional startup can result in serious injury.  
Broken bones, fractures, bruises or sprains could result.

When starting engine, pull the starter cord slowly 
until resistance is felt and then pull rapidly to avoid 
kickback.
DO NOT start or stop the engine with electrical 
devices plugged in.

WARNING

Exceeding the generator’s running capacity can 
damage the generator and/or electrical devices 
connected to it.

DO NOT overload the generator.
Start the generator and allow the engine to stabilize 
before connecting electrical loads.
Connect electrical equipment in the off position, 
and then turn them on for operation.
Turn electrical equipment off before stopping the 
generator.
DO NOT tamper with the governed speed. 
DO NOT modify the generator in any way.

CAUTION

Generator exhaust contains carbon monoxide, a 
colorless, odorless, poison gas. Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death. If you start to feel dizzy or weak, get to fresh 
air immediately.

Operate generator outdoors only in a well ventilated 
area.
DO NOT operate the generator inside any building, 
including garages, basements, crawlspaces and 
sheds, enclosure or compartment, including the 
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings.

DANGER CARBON MONOXIDE:

 using a generator 

indoors

 CAN KILL YOU IN MINUTES

.

dANGER

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories. 
Traumatic amputation or severe laceration can result.

Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught.

dANGER

Generator produces powerful voltage.

DO NOT touch bare wires or receptacles.

DO NOT use electrical cords that are worn, damaged 

or frayed.

DO NOT operate generator in wet weather.

DO NOT allow children or unqualified persons to 

operate or service the generator

Use a ground fault circuit interrupter (GFCI) in damp 

areas and areas containing conductive material such 

as metal decking.

Use approved transfer equipment to isolate generator 

from your electric utility and Notify your utility 

company before connecting your generator to your 

power system.

dANGER

Sparks can result in fire or electrical shock.

When servicing the generator:

Disconnect the spark plug wire and place it where it 

cannot contact the plug.

DO NOT check for spark with the plug removed.

Use only approved spark plug testers.

WARNING

Running engines produce heat. Severe burns can 

occur on contact. 

Combustible material can catch fire on contact.

DO NOT touch hot surfaces.

Avoid contact with hot exhaust gases.

Allow equipment to cool before touching.

Maintain at least 3 ft. (91.4 cm) of clearance on all 

sides to ensure adequate cooling.

Maintain at least 5 ft. (1.5 m) of clearance from 

combustible materials.

WARNING

Medical and Life Support Uses.

In an emergency, call emergency services immediately.
NEVER use this product to power life support 
devices or life support appliances.
NEVER use this product to power medical devices 
or medical appliances.
Inform your electricity provider immediately if you 
or anyone in your household depends on electrical 
equipment to live.
Inform your electrical provider immediately if a 
loss of power would cause you or anyone in your 
household to experience a medical emergency.

WARNING

The engine exhaust from this product contains 
chemicals that are known to cause serious health 
problems and even death.

WARNING

Read this manual thoroughly before operating your 
generator. Failure to follow instructions could result 
in serious injury or death.

WARNING

Operation of this equipment may create sparks that 

can start fires around dry vegetation.

A spark arrestor may be required. The operator 

should contact local fire agencies for laws or 

regulations relating to fire prevention requirements.

WARNING

Fuel and fuel vapors are highly flammable and 
extremely explosive. 
Fire or explosion can cause severe burns or death.  
Unintentional startup can result in entanglement, 
traumatic amputation or laceration. 

When adding or removing fuel:

Turn the generator off and let it cool for at least two 
minutes before removing the fuel cap. Loosen the 
cap slowly to relieve pressure in the tank.
Only fill or drain fuel outdoors in a well-ventilated area.
DO NOT pump gas directly into the generator at the 
gas station. Use an approved container to transfer 
the fuel to the generator.
DO NOT overfill the fuel tank.
Always keep fuel away from sparks, open flames, 
pilot lights, heat and other sources of ignition.
DO NOT light or smoke cigarettes.

When starting the generator:

DO NOT attempt to start a damaged generator. 
Make certain that the gas cap, air filter, spark plug, 
fuel lines and exhaust system are properly in place.
Allow spilled fuel to evaporate fully before 
attempting to start the engine.
Make certain that the generator is resting firmly on 
level ground.

When operating the generator:

DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.

When transporting or servicing the generator:

Make certain that the fuel shutoff valve is in the off 
position and the fuel tank is empty.
Disconnect the spark plug wire.

When storing the generator:

Store away from sparks, open flames, pilot lights, 
heat and other sources of ignition.

dANGER

Содержание CPG 9000 E2

Страница 1: ...a d a d e dos a os G a r a n t a l i m i t a d a d e dos a os T h ree Year Limited Warran t y T h ree Year Limited Warran t y G a r a n t a l i m i t a d a de un a o G a r a n t a l i m i t a d a de u...

Страница 2: ...us injury WARNING If you have questions regarding your generator we can help Please contact yor local dealer NOTE Record the model and serial numbers as well as date and place of purchase for future r...

Страница 3: ...r system DANGER Sparks can result in fire or electrical shock When servicing the generator Disconnect the spark plug wire and place it where it cannot contact the plug DO NOT check for spark with the...

Страница 4: ...1 2 for the black battery lead 1 Place the generator on a flat level surface 2 Remove oil fill cap dipstick to add oil 3 Add oil and replace oil fill cap dipstick DO NOT OVERFILL 4 Check engine oil le...

Страница 5: ...operate the generator inside any building See safety warnings section In some areas generators must be registered with the local utility company Generators used on construction sites may be subject to...

Страница 6: ...low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold NOTE Keep choke lever in Choke position for only 1 pull of the recoil starter After first...

Страница 7: ...air intake and muffler First 5 Hours Change oil Every 50 hours or every season Clean air filter Change oil if operating under heavy load or in hot environments Every 100 hours or every season Change o...

Страница 8: ...ric starting proper battery maintenance and storage should be followed An automatic battery charger not included with automatic trickle charging capability should be used to charge the battery Maximum...

Страница 9: ...Steel Engine Oil Type 10W 30 10W 30 10W 30 Engine Oil Capacity 0 6 L 0 6 L 0 6 L Engine Oil Included No No No Low Oil Shut Off Yes Yes Yes Wheels No No No CE Certified Yes Yes Yes SPECIFICATIONS CPG6...

Страница 10: ...5 1 73 23 040002 00 Valve Intake 1 22 21 060001 01 Pulley Starter 1 74 23 040006 00 Valve Exhaust 1 23 23 080001 00 Cooling Fan 1 75 26 080400 00 Air Guide Lower 1 24 24 120100 06 Flywheel 1 76 2 15 0...

Страница 11: ...5 1 Bolt M6 x 15 Black 4 17 122 190003 00 48 End Cover Generator Yellow 1 57 1 818 0514 2 Screw M5 x 14 1 18 1 9074 15 0520 Washer Assembly M5 x 20 1 58 5 1810 001 Over Voltage Protector 1 19 122 1900...

Страница 12: ...5 1 73 23 040002 00 Valve Intake 1 22 21 060001 01 Pulley Starter 1 74 23 040006 00 Valve Exhaust 1 23 23 080001 00 Cooling Fan 1 75 26 080400 00 Air Guide Lower 1 24 24 120100 06 Flywheel 1 76 2 15 0...

Страница 13: ...122 210007 26 Control Box 1 17 122 190003 00 48 End Cover Generator Yellow 1 56 1 5789 0615 1 Bolt M6 x 15 Black 4 18 1 9074 15 0520 Washer Assembly M5 x 20 1 57 1 818 0514 2 Screw M5 x 14 1 19 122 19...

Страница 14: ...01 00 Retainer Intake Valve Spring 1 24 24 120100 07 Flywheel 1 82 21 040008 00 Rotator Exhaust Valve 1 25 2 11 001 Oil Seal 25 41 3 6 2 83 24 040202 00 Shaft Rocker Arm 1 26 2 03 020 1 Washer 6 2 15...

Страница 15: ...19 1 16674 0512 2 Flange Bolt M5 x 12 3 65 1 5789 0845 Flange Bolt M8 x 45 2 20 122 190400 00 Terminal Block 1 66 5 1900 009 Black Wire Battery 1 21 122 190004 01 Pinch 1 67 5 1900 010 Red Wire Batter...

Страница 16: ...20 013 Receptacle 2 25 1 93 05 Spring Washer 5 5 85 1 819 0414 2 Bolt and Washer Assembly M4 x 14 8 26 1 5783 0520 Bolt M5 x 20 1 86 1 6177 1 04 2 Nut M4 8 27 122 190400 00 Terminal Block 1 87 5 1210...

Страница 17: ...023 Washer 12 5 20 2 Drain Bolt 2 87 45 130001 00 Insulator Carburetor 1 27 46 030100 01 Crankcase 1 88 46 130003 20 Gasket Carburetor 1 28 45 127000 02 Oil Level Sensor 1 89 46 131000 22 Carburetor...

Страница 18: ...sher 12 5 20 2 Drain Bolt 1 87 45 130001 00 Insulator Carburetor 1 27 48 030100 00 Crankcase 1 88 46 130003 20 Gasket Carburetor 1 28 45 127000 02 Oil Level Sensor 1 89 48 131000 11 Carburetor 1 29 1...

Страница 19: ...122 190004 01 Pinch 1 83 5 1120 013 Receptacle 2 25 1 93 05 Spring Washer 5 5 84 1 819 0414 2 Bolt and Washer Assembly M4 x 14 8 26 1 5783 0520 Bolt M5 x 20 1 85 1 6177 1 04 2 Nut M4 8 27 122 190400...

Страница 20: ...K BLUE GREEN RED WHITE Br WHITE BLUE GREEN YELLOW WHITE GREEN BROWN BLACK WHITE B W W L G Y W G B G BLACK GREEN B Y ENGINE BLOCK GENERATOR BLOCK SPARKING PLUG IGNITION COIL OIL LEVEL SW CONTROL BOX BL...

Страница 21: ......

Отзывы: