COMPRESSOR PILOT VALVE PRESSURE ADJUSTMEN
T
(DUAL CONTROL UNITS ONLY)
Proceed with the following instructions while compressor is running:
1.
Loosen locknut (2) and back off several turns.
2.
Check reading on the tank pressure gauge. Set the pressure to 30 psig differential (unload at 95
psig, reload at 65 psig). Turn nut (3) clockwise to increase differential pressure or counterclockwise
to decrease differential pressure.
3.
After pressure is set, tighten locknut (2). Be careful not to move nut (3).
COMPRESSOR PILOT VALVE DIFFERENTIAL PRESSURE ADJUSTMENT
Proceed with the following instructions while compressor is running.:
1.
Loosen locknut (2) and back off several turns.
2.
Check reading on the tank pressure gauge. Set the pressure to 30 psig differential (unload at 95
psig, reload at 65 psig). Turn nut (3) clockwise to increase differential pressure or
counterclockwise to decrease differential pressure.
3.
After pressure is set, tighten locknut (2). Be careful not to move nut (3).