background image

5

  

REV 46554-20101116

ENGLISH

 

46554

Read this owner’s manual before operating your generator . Familiarize yourself with the location and function of the 
controls and features . Save this manual for future reference .

(1)  Fuel Tank

 – 4 .0 gallon (15 L) capacity fuel tank .

(2)  Choke Lever

 – Used to start the engine . 

(3)  Fuel Valve

 – Turn this valve to the “On” position to 

supply fuel to the engine .

(4)  Air Cleaner

 – Protects the engine by filtering dust 

and debris from the intake air .

(5)  Recoil Starter

 – Used to start the engine .

(6)  Low Oil Sensor

 – Senses the level of oil in the 

crankcase and shuts the engine down if the level 
falls too low .

(7)  Oil Filler Cap

 – Check and fill engine oil level .

(8)  Power Panel

 – See “Power Panel” .

1

2

4

5

6

7

8

Generator

CONTROLS ANd fEATuRES

3

Содержание 46554

Страница 1: ...ngs CA 90670 USA 1 877 338 0999 www championpowerequipment com 4000 Starting Watts 3000 Max Rated Watts PORTABLE GENERATOR SAvE ThESE INSTRuCTIONS Important Safety Instructions are included in this ma...

Страница 2: ...is product to the store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call o...

Страница 3: ...intenance And Storage 11 Engine Maintenance 11 Oil 11 Spark Plugs 11 Air Filter 11 Cleaning 12 Adjustments 12 Maintenance Schedule 12 Generator Maintenance 12 Storage 12 Engine Storage 12 Generator St...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...inds of information The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment Follow all safety messages to avoid or reduce the risk of seriou...

Страница 6: ...ged or frayed DO NOT operate generator in wet weather DO NOT allow children or unqualified persons to operate or service the generator Use a ground fault circuit interrupter GFCI in damp areas and are...

Страница 7: ...nd and arm towards the engine faster than you can let go Unintentional startup can result in entanglement traumatic amputation or laceration Broken bones fractures bruises or sprains could result When...

Страница 8: ...ver Used to start the engine 3 Fuel Valve Turn this valve to the On position to supply fuel to the engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil St...

Страница 9: ...120 Volt AC 60 Hz Your 46554 Gasoline Powered Generator ships with the following parts Spark Arrester Kit Spark Arrestor 1 Cover Plate 1 Screw with Lock Washer 2 Other 18 Power Cord 1 Wind Up Flashlig...

Страница 10: ...e axle to the frame with four cap screws M8x16 and lock nuts M8 3 Slide a wheel onto the axle 4 Place a washer on the end 5 Install the cotter pin through the hole on the end of the axle 6 Carefully b...

Страница 11: ...spilled fuel Add Fuel Cont d Add Oil Cont d 3 Add 0 63 qt 0 6 L of oil and replace oil fill cap dipstick See Specifications page in the manual for oil recommendations based on operating conditions 4 C...

Страница 12: ...the On position 4 Flip the engine switch to the On position 5 Move the choke lever to the Choke position 6 RECOIL START Pull the starter cord slowly until resistance is felt and then pull rapidly 7 As...

Страница 13: ...1200 Table Saw 2000 2000 Operation Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes 1 Select the electrical devices...

Страница 14: ...roved waste management facility Air filter 1 Remove the snap on cover holding the air filter to the assembly 2 Remove the foam element 3 Wash in liquid detergent and water Squeeze thoroughly dry in a...

Страница 15: ...park arrester Clean fuel tank and filter Every 3 years Replace fuel line Maintenance and Storage Generator Maintenance Make certain that the generator is kept clean and stored properly Only operate th...

Страница 16: ...Length 23 2 inches 59 cm Spark Plugs Recommended replacement spark plug NGK BR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 mm or 0 028 0 031 in Specifications Oil Use 4 Cycle automotiv...

Страница 17: ...REV 46554 20101116 14 46554 ENGLISH Wiring Diagram Specifications...

Страница 18: ...15 REV 46554 20101116 ENGLISH 46554 Parts Diagram Specifications...

Страница 19: ...Defend Board 2 39 ST02FD 02100013 14 CSA Earth Line 1 40 GB6177 M6 Nut M6 1 41 ST02FD 1151300C 1 Bottom Rubber II 2 42 GB6177 M8 Nut M8 12 43 ST02 1151400 Rubber Pad 4 Part Number Description Qty 44...

Страница 20: ...17 REV 46554 20101116 ENGLISH 46554 Specifications Engine Parts Diagram...

Страница 21: ...4 Governor Arm Bolt 1 47 GB5789 86 FB6 25 Flange Bolt 6X25 2 48 ST160F 1123000 G Ignition 1 49 152FMD 1001007 Dowel Pin 10X16 2 50 GB5789 86 FB8 55 Flange Bolt 8X55 4 Part Number Description Qty 51 ST...

Страница 22: ...adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected device is defec...

Страница 23: ...will not apply to parts and or labour if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or c...

Отзывы: