Installation
Ventilation -
Vent Hood Fan Control
Standard model installations using an approved vent hood may require a vent
fan signal. This signal is supplied by the dishwasher control circuit. A qualified
installer must connect a signal circuit to the fuse holder and a common
neutral terminal provided. See Fig. 8.
CAUTION:
To prevent damage to the dishwasher do not connect vent fan motor to the Line Power
120VAC, 0.5 Amp fused connection terminals. Damage to any component caused by improper installation is not
covered by the limited warranty.
The fused 120VAC Line Power only supplies an external vent fan contactor
(supplied by others), and is limited to 0.5 AMP maximum load. The 120VAC is
powered whenever main power is on.
Fig. 8 - Connection is located inside the top control cabinet.
Continued on next page.
0.5A