SAfETy RULES

Generator exhaust contains carbon monoxide, a 
colorless, odorless, poison gas . Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death . If you start to feel dizzy or weak, get to fresh 
air immediately .

Operate generator outdoors only in a well ventilated 
area .
DO NOT operate the generator inside any building, 
including garages, basements, crawlspaces and 
sheds, enclosure or compartment, including the 
generator compartment of a recreational vehicle .
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings .
DANGER CARBON MONOXIDE: using a generator 
indoors

 CAN KILL YOU IN MINUTES .

DANGER

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories . 
Traumatic amputation or severe laceration can result .

Keep hands and feet away from rotating parts .
Tie up long hair and remove jewelry .
Operate equipment with guards in place .
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught .

DANGER

Generator produces powerful voltage .

DO NOT touch bare wires or receptacles .

DO NOT use electrical cords that are worn, damaged 

or frayed .

DO NOT operate generator in wet weather .

DO NOT allow children or unqualified persons to 

operate or service the generator

Use a ground fault circuit interrupter (GFCI) in damp 

areas and areas containing conductive material such 

as metal decking .

Use approved transfer equipment to isolate generator 

from your electric utility and Notify your utility 

company before connecting your generator to your 

power system .

DANGER

Sparks can result in fire or electrical shock .

When servicing the generator:

Disconnect the spark plug wire and place it where it 

cannot contact the plug .

DO NOT check for spark with the plug removed .

Use only approved spark plug testers .

WARNING

Running engines produce heat . Severe burns can 

occur on contact . 

Combustible material can catch fire on contact .

DO NOT touch hot surfaces .

Avoid contact with hot exhaust gases .

Allow equipment to cool before touching .

Maintain at least three feet of clearance on all sides 

to ensure adequate cooling .

Maintain at least five feet of clearance from 

combustible materials .

WARNING

Medical and Life Support Uses .

In case of emergency, call 911 immediately .
NEVER use this product to power life support 
devices or life support appliances .
NEVER use this product to power medical devices 
or medical appliances .
Inform your electricity provider immediately if you 
or anyone in your household depends on electrical 
equipment to live .
Inform your electrical provider immediately if a 
loss of power would cause you or anyone in your 
household to experience a medical emergency .

WARNING

The engine exhaust from this product contains 
chemicals known to the state of California to cause 
cancer, birth defects, or other reproductive harm .

WARNING

Read this manual thoroughly before operating your 
generator . Failure to follow instructions could result 
in serious injury or death .

WARNING

Содержание 41537

Страница 1: ...Springs CA 90670 USA 1 877 338 0999 www championpowerequipment com SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 41537 20120730 41537 MODEL NUMBE...

Страница 2: ...the store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Ca...

Страница 3: ...aintenance 13 Oil 13 Spark Plugs 13 Air Filter 13 Spark Arrester 14 Cleaning 14 Adjustments 14 Maintenance Schedule 14 Generator Maintenance 15 Storage 15 Generator Storage 15 Disconnect the Battery 1...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can r...

Страница 7: ...or off and let it cool for at least two minutes before removing the fuel cap Loosen the cap slowly to relieve pressure in the tank Only fill or drain fuel outdoors in a well ventilated area DO NOT pum...

Страница 8: ...choke valve Used when starting a cold engine 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Sta...

Страница 9: ...inst electrical overloads Push to reset breaker 4 120 240 Volt AC 30 Amp Twist Lock Receptacle NEMA L14 30R May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp si...

Страница 10: ...lange Bolt M10x120 for Wheel 2 Bushing 2 Flat Washer 10 2 Nut M10 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Nut M8 2 Other 25 ft 7 62 m Generator Cable 1 Oil 1 16 qt 1 1 L...

Страница 11: ...d oil tip the generator on it s side 2 Slide the M10x120 wheel bolt through the washer sleeve and wheel 3 Slide the bolt through the mount point on the frame 4 Fasten securely with the M10 nut 5 Repea...

Страница 12: ...sion 6 Screw on the fuel cap and wipe away any spilled fuel Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock A ground terminal connected to t...

Страница 13: ...ive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Voltage fluctuation may impair the proper fu...

Страница 14: ...connection to the utility company power lines You are responsible for ensuring that your generator s electricity does not feed back into the electric utility power lines If the generator will be conn...

Страница 15: ...evations the standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING...

Страница 16: ...clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove the spark plug...

Страница 17: ...he end of the spark arrester to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if i...

Страница 18: ...ded periods of time make sure that the Ignition Switch the Fuel Valve and the Battery Switch are set in the the the OFF position and the battery leads have been disconnected from the battery DANGER A...

Страница 19: ...Frequency 60 Hz Fuel Capacity 5 9 gallons 22 4 L Gross Weight 236 6 lbs 107 3 kg Net Weight 219 3 lbs 99 7 kg Height 26 0 inches 66 1 cm Width 27 1 inches 68 8 cm Length 27 7 inches 70 48 cm Specific...

Страница 20: ...6 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 38 44 45 46 37 38 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 26 24 85 86 87...

Страница 21: ...0 1 55 ST07FD 02011100 Stator Assembly 1 56 GB7244 10 locking washer 10 1 57 GB96 10 Washer 10 1 58 ST07FD 02011200 Rotor Assembly 1 59 GB5789 M6 8 Flange Bolt M6 8 2 60 ST05FD 1151600 Air Guide 1 Par...

Страница 22: ...19 REV 41537 20120730 ENGLISH 41537 Specifications Engine Parts Diagram...

Страница 23: ...0003 Second ring set 1 57 ST190F 1050002 First ring set 1 58 ST188F 1030013 Dowel pin 2 59 ST190F 1030008 G Cylinder head casket 1 60 ST188F 1080001 G Shroud 1 61 ST190F 2 1011000 G Head comp 1 Part N...

Страница 24: ...21 REV 41537 20120730 ENGLISH 41537 Wiring Diagram Specifications...

Страница 25: ...e to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient venti...

Страница 26: ...r labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any ele...

Страница 27: ...diagnosis parts and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EM...

Страница 28: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 29: ...ting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof...