Connecting Electrical Loads

1 .  Let the engine stabilize and warm up for a few 

minutes after starting

2 .  Plug in and turn on the desired 120/240 Volt AC 

single phase, 60 Hz electrical loads .

 

– DO NOT connect 3-phase loads to the generator .

 

– DO NOT connect 50 Hz loads to the generator .

 

– DO NOT overload the generator .

Connecting a generator to your electric utility 
company’s power lines or to another power source 
may be against the law . In addition this action, 
if done incorrectly, could damage your generator 
and appliances and could cause serious injury or 
even death to you or a utility worker who may be 
working on nearby power lines . If you plan to run a 
portable electric generator during an outage, please 
notify your electric utility company immediately 
and remember to plug your appliances directly 
into the generator . Do not plug the generator into 
any electric outlet in your home . Doing so could 
create a connection to the utility company power 
lines . You are responsible for ensuring that your 
generator’s electricity does not feed back into the 
electric utility power lines .
If the generator will be connected to a building 
electrical system, consult your local utility company 
or a qualified electrician . Connections must isolate 
generator power from utility power and must comply 
with all applicable laws and codes .

NOTE

OPERATION

Stopping the Engine

1 .  Turn off and unplug all electrical loads . Never start 

or stop the generator with electrical devices plugged 
in or turned on .

2 .  Let the generator run at no-load for several minutes 

to stabilize internal temperatures of the engine and 
generator .

3 .  Turn the Fuel Valve to the “OFF” position .
4 .  Let the engine run until fuel starvation has stopped 

the engine . This usually takes a few minutes .

5 .  Press the engine switch to the “OFF” position .
Important: Always ensure that the Fuel Valve and the 
Engine Switch are in the “OFF” position when the engine 
is not in use .

If the engine will not be used for a period of two (2) weeks 
or longer, please see the Storage section for proper engine 
and fuel storage .

NOTE

Содержание 41537

Страница 1: ...Springs CA 90670 USA 1 877 338 0999 www championpowerequipment com SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 41537 20120730 41537 MODEL NUMBE...

Страница 2: ...the store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Ca...

Страница 3: ...aintenance 13 Oil 13 Spark Plugs 13 Air Filter 13 Spark Arrester 14 Cleaning 14 Adjustments 14 Maintenance Schedule 14 Generator Maintenance 15 Storage 15 Generator Storage 15 Disconnect the Battery 1...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can r...

Страница 7: ...or off and let it cool for at least two minutes before removing the fuel cap Loosen the cap slowly to relieve pressure in the tank Only fill or drain fuel outdoors in a well ventilated area DO NOT pum...

Страница 8: ...choke valve Used when starting a cold engine 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Sta...

Страница 9: ...inst electrical overloads Push to reset breaker 4 120 240 Volt AC 30 Amp Twist Lock Receptacle NEMA L14 30R May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp si...

Страница 10: ...lange Bolt M10x120 for Wheel 2 Bushing 2 Flat Washer 10 2 Nut M10 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Nut M8 2 Other 25 ft 7 62 m Generator Cable 1 Oil 1 16 qt 1 1 L...

Страница 11: ...d oil tip the generator on it s side 2 Slide the M10x120 wheel bolt through the washer sleeve and wheel 3 Slide the bolt through the mount point on the frame 4 Fasten securely with the M10 nut 5 Repea...

Страница 12: ...sion 6 Screw on the fuel cap and wipe away any spilled fuel Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock A ground terminal connected to t...

Страница 13: ...ive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Voltage fluctuation may impair the proper fu...

Страница 14: ...connection to the utility company power lines You are responsible for ensuring that your generator s electricity does not feed back into the electric utility power lines If the generator will be conn...

Страница 15: ...evations the standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING...

Страница 16: ...clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove the spark plug...

Страница 17: ...he end of the spark arrester to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if i...

Страница 18: ...ded periods of time make sure that the Ignition Switch the Fuel Valve and the Battery Switch are set in the the the OFF position and the battery leads have been disconnected from the battery DANGER A...

Страница 19: ...Frequency 60 Hz Fuel Capacity 5 9 gallons 22 4 L Gross Weight 236 6 lbs 107 3 kg Net Weight 219 3 lbs 99 7 kg Height 26 0 inches 66 1 cm Width 27 1 inches 68 8 cm Length 27 7 inches 70 48 cm Specific...

Страница 20: ...6 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 38 44 45 46 37 38 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 26 24 85 86 87...

Страница 21: ...0 1 55 ST07FD 02011100 Stator Assembly 1 56 GB7244 10 locking washer 10 1 57 GB96 10 Washer 10 1 58 ST07FD 02011200 Rotor Assembly 1 59 GB5789 M6 8 Flange Bolt M6 8 2 60 ST05FD 1151600 Air Guide 1 Par...

Страница 22: ...19 REV 41537 20120730 ENGLISH 41537 Specifications Engine Parts Diagram...

Страница 23: ...0003 Second ring set 1 57 ST190F 1050002 First ring set 1 58 ST188F 1030013 Dowel pin 2 59 ST190F 1030008 G Cylinder head casket 1 60 ST188F 1080001 G Shroud 1 61 ST190F 2 1011000 G Head comp 1 Part N...

Страница 24: ...21 REV 41537 20120730 ENGLISH 41537 Wiring Diagram Specifications...

Страница 25: ...e to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient venti...

Страница 26: ...r labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any ele...

Страница 27: ...diagnosis parts and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EM...

Страница 28: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 29: ...ting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof...

Отзывы: