100460 - 3550W PORTAbLE GENERATOR
ASSEMbLY
15
1. Place the generator on a flat, level surface.
2. Remove oil fill cap/dipstick to add oil.
3. Using a funnel, add up to 0.6 qt. (0.6 L) of oil (not included)
and replace oil fill cap/dipstick. DO NOT OVERFILL.
4. Check engine oil level daily and add as needed.
MAX
MIN
OIL DIP STICK
NOTICE
Once oil has been added, a visual check should show oil
about 1-2 threads from running out of the fill hole.
If using the dipstick to check oil level, DO NOT screw in the
dipstick while checking.
NOTICE
Check oil often during the break-in period. Refer to the
Maintenance
section for recommended service intervals.
CAUTION
The engine is equipped with a low oil shut-off and will stop
when the oil level in the crankcase falls below the threshold
level.
NOTICE
The first 5 hours of run time are the break-in period for the
unit. During the break in period stay at or below 50% of the
running watt rating and vary the load occasionally to allow
stator windings to heat and cool. Adjusting the load will also
cause engine speed to vary and help seat piston rings. After
the 5 hour break-in period, change the oil.
NOTICE
Weather will affect engine oil and engine performance.
Change the type of engine oil used based on weather
conditions to suit the engine needs.
NOTICE
Synthetic oil may be used after the 5 hour initial break-
in period. Using synthetic oil does not increase the
recommended oil change interval. Full synthetic 5W-30 oil
will aid in starting in cold ambient <5º C (41º F).
Add fuel
1. Use clean, fresh, regular unleaded gasoline with a
minimum octane rating of 85 and an ethanol content of
10% or less by volume.
y b c
2. DO NOT mix oil with gasoline.
3. Remove the gasoline cap.
4. Slowly add gasoline to the tank. Tank is full when gasoline
reaches red circle on screen. DO NOT OVERFILL. Gasoline
can expand after filling. A minimum of ¼ in. (6.4 mm) of
space left in the tank is required for gasoline expansion,
although more than ¼ in. (6.4 mm) is recommended.
Gasoline can be forced out of the tank as a result of
expansion if overfilled, and can affect the stable running
condition of the generator.
5. Screw on the gasoline cap and wipe away any spilled fuel.