MAINTENANCE AND STORAGE
The owner/operator is responsible for all periodic
maintenance.
Complete all scheduled maintenance in a timely manner.
Correct any issue before operating the generator.
Air filter
1. Remove the maintenance cover.
2. Locate the air filter plastic cover.
3. Unsnap the locking hinge on the cover.
4. Remove the old filter.
5. Place the new filter in the assembly.
6. Re-snap the hinge on the air filter cover.
7. Reinstall the maintenance cover and tighten the
cover screw securely.
Spark Plugs
1. Remove the maintenance cover.
2. Remove the spark plug cable from the spark plug
3. Use a spark socket (not included) to remove the plug.
4. Remove the spark plug.
5. Inspect the electrode on the plug. It must be clean
and not worn to produce the spark required for
ignition.
6. Make certain the spark plug gap is 0.7 - 0.8 mm
(0.028 - 0.031 in.).
7. Carefully thread the plug into the engine.
8. Use a spark plug socket (not included) to firmly
install the plug.
9. Attach the spark plug cap to the plug.
10. Reinstall the spark plug access cap, and
maintenance cover.
For service or parts assistance, contact our help
line at
1-877-338-0999
NOTE
Maintenance, replacement, or repair of emission
control devices and systems may be performed
by any non-road engine repair establishment or
individual.
NOTE
Never operate a damaged or defective generator.
WARNING
Tampering with the factory set governor will void
your warranty.
WARNING
Improper maintenance will void your warranty.
WARNING
Oil Cont’d.
0.7 - 0.8 mm
0.028 - 0.031 in.
Once oil has been added, a visual check should show
oil about 1-2 threads from running out of the fill hole.
If using the dipstick to check oil level, DO NOT screw
in the dipstick while checking.
NOTE
Engine Maintenance
To prevent accidental starting, remove and ground spark
plug wire before performing any service.
Oil
Change oil when the engine is warm. Refer to the oil
specification to select the proper grade of oil for your
operating environment.
1. Set the generator on top of a work bench or table.
2. Loosen the cover screws and remove the
maintenance cover.
3. Pop up the rubber maintenance plug, from below the
drain bolt.
4. Remove the drain bolt.
5. Allow the oil to drain completely.
6. Replace the drain plug.
7. Add up to 0.6 L (0.6 qt.) of oil and replace oil fill
cap/dipstick. DO NOT OVERFILL.
8. Reinstall the maintenance cover and tighten the
cover screws.
9. Dispose of used oil at an approved waste
management facility.