Champion 100387 Скачать руководство пользователя страница 13

10

100387

 

ENGLISH

ASSEMBLy

Add Engine Oil Cont’d.

Synthetic oil may be used after the 5 hour initial 
break-in period. Using synthetic oil does not 
increase the recommended oil change interval. 
Full synthetic 5W-30 oil will aid in starting in cold 
ambient <5ºC (41ºF)

NOTE

Weather will affect engine oil and engine 
performance. Change the type of engine oil used 
based on weather conditions to suit the engine 
needs.

NOTE

Add fuel

1.  Use clean, fresh, regular unleaded fuel with a 

minimum octane rating of 85 and an ethanol content 
of less than 10% by volume.

2.  DO NOT mix oil with fuel.
3.  Clean the area around the fuel cap. 
4.  Remove the fuel cap.
5.  Slowly add fuel to the tank. DO NOT OVERFILL. Fuel 

can expand after filling. A minimum of 6.4 mm (¼ in.) 
of space left in the tank is required for fuel expansion, 
more than 6.4 mm (¼ in.) is recommended. Fuel 
can be forced out of the tank as a result of expansion 
if it is overfilled, and can affect the stable running 
condition of the product. When filling the tank, it is 
recommended to leave enough space for the fuel to 
expand.

6.  Screw on the fuel cap and wipe away any spilled fuel.

Use regular unleaded gasoline with a minimum 
octane rating of 85.

Do not mix oil and gasoline.
Fill tank to approximately 6.4 mm (¼ in.) below the 
top of the tank to allow for fuel expansion.
DO NOT pump gas directly into the generator at the 
gas station. Use an approved container to transfer 
the fuel to the generator.
DO NOT fill fuel tank indoors.
DO NOT fill fuel tank when the engine is running or hot.
DO NOT overfill the fuel tank.
DO NOT light cigarettes or smoke when filling the 
fuel tank.

CAUTION

Pouring fuel too fast through the fuel screen may 
result in blow back of fuel at the operator while filling.

WARNING

Add fuel Cont’d.

Our engines work well with 10% or less ethanol 
blend fuels. When using blended fuels there are 
some issues worth noting: 

 

– Ethanol-gasoline blends can absorb more water 

than gasoline alone. 

 

– These blends can eventually separate, leaving 

water or a watery goo in the tank, fuel valve and 
carburetor. 

 

– With gravity-fed fuel supplies, this compromised 

fuel can be drawn into the carburetor and cause 
damage to the engine and/or potential hazards. 

 

– There are only a few suppliers of fuel stabilizer 

that are formulated to work with ethanol blend 
fuels.

 

– Any damages or hazards caused by using 

improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not 
covered by manufacture’s warranty. 

It is advisable to always shut off the fuel supply, 
run the engine to fuel starvation and drain the tank 
when the equipment is not in use for more than 30 
days.

NOTE

Grounding

Your generator must be properly connected to an 
appropriate ground to help prevent electric shock.

A ground terminal connected to the frame of the generator 
has been provided on the power panel. For remote 
grounding, connect a length of heavy gauge (12 AWG 
minimum) copper wire between the generator ground 
terminal and a copper rod driven into the ground. We 
strongly recommend that you consult with a qualified 
electrician to ensure compliance with local electrical codes.

Failure to properly ground the generator can result 
in electric shock.

WARNING

Содержание 100387

Страница 1: ...nt y T wo Year Limited Warrant y d e d e u x a n s d e d e u x a n s G a r a n t í a l i m i t G a r a n t í a l i m i t T h ree Year Limited Warran t y T h ree Year Limited Warran t y G a r a n t í a l i m G a r a n t í a l i m d e t r o i s a n s d e t r o i s a n s T wo Year Limited Warrant y G a rantie limitée de deux a n s T wo Year Limited Warrant y G a rantie limitée de deux a n s O ne Year...

Страница 2: ...cover Parts Ordering Mon Fri 8 30 AM 5 00 PM PST PDT Toll free 1 877 338 0999 AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40 C 104 F When your product is needed it may be operated at temperatures ranging from 15 C 5 F to 50 C 122 F for short periods If the product is exposed to temperature...

Страница 3: ...ngine 13 Do Not Overload Generator 13 Power Management 14 Overload Operation 14 Parallel Operation 14 Operation at High Altitude 14 Maintenance and Storage 15 Engine Maintenance 15 Oil 15 Spark Plugs 15 Air Filter 15 Spark Arrester 16 Adjustments 16 Maintenance Schedule 16 Generator Maintenance 17 Cleaning 17 Storage 17 Short Term Storage up to 1 year 17 Long Term Storage over 1 year 17 Removing f...

Страница 4: ... completeness of the information in this manual and we reserve the right to change alter and or improve the product and this document at any time without prior notice Since CPE highly values how our products are designed manufactured operated and serviced and also highly values your safety and the safety of others we would like you to take the time to review this product manual and other product m...

Страница 5: ...us situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage CAUTION DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury DANGER WARNING indicates a potentially hazardous situation w...

Страница 6: ...er GFCI in damp areas and areas containing conductive material such as metal decking Use approved transfer equipment to isolate generator from your electric utility and notify your utility company before connecting your generator to your power system DANGER Sparks can result in fire or electrical shock When servicing the generator Disconnect the spark plug wire and place it where it cannot contact...

Страница 7: ...sparks that can start fires around dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements WARNING Fuel and fuel vapours are highly flammable and extremely explosive Fire or explosion can cause severe burns or death Unintentional startup can result in entanglement traumatic amputation or lacera...

Страница 8: ...manual Para evitar daños al motor el parachispas debe de limpiarse CADA 100 HORAS Para un plan de mantenimiento vea el manual del propietario Pour prévenir les dommages au moteur le pare étincelles devrait être nettoyé TOUTES LES 100 HEURES Pour le calendrier d entretien consulter le manuel du propriétaire GN OP T 004 2 131 x 19 mm BLACK DANGER NEVER use inside a home or garage EVEN IF doors and w...

Страница 9: ...function of the controls and features Save this manual for future reference 1 Fuel Cap Remove to add fuel 2 Recoil Starter Used to start the engine 3 Power Panel See Power Panel section 4 Foldaway Handle Generator Controls and Features 1 5 6 4 7 2 3 5 Muffler 6 Maintenance Cover 7 Never Flat Wheel 8 Carrying Handle 8 ...

Страница 10: ...operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 10 Output Light Remains ON during normal operating conditions Shuts OFF when generator is overloaded 11 Overload Indicator Light This light turns ON when the generator is overloaded and will cut power to the receptacles 12 Oil Warning Light Check oil level when this light turns on Engine will not run when indicator is lit 13 Engin...

Страница 11: ... Automotive Style Battery Charger Cables 1 RV Adapter 1 ECO The below symbols are located on the generator power panel Familiarize yourself with these symbols for quick reference of the components and their function Engine On Fuel Valve On Economy Mode Output Ground Engine Switch Overload Parallel Engine Stop Low Oil Press to reset circuit breakers Fuel Valve Fuel Valve Off Direct Current RESET ...

Страница 12: ...ften during the break in period Refer to the Maintenance section for recommended service intervals NOTE The generator rotor has a sealed pre lubricated ball bearing that requires no additional lubrication for the life of the bearing NOTE Add Engine Oil Cont d We consider the first 5 hours of run time to be the break in period for the unit During the break in period stay at or below 50 of the runni...

Страница 13: ...the engine is running or hot DO NOT overfill the fuel tank DO NOT light cigarettes or smoke when filling the fuel tank CAUTION Pouring fuel too fast through the fuel screen may result in blow back of fuel at the operator while filling WARNING Add Fuel Cont d Our engines work well with 10 or less ethanol blend fuels When using blended fuels there are some issues worth noting Ethanol gasoline blends...

Страница 14: ... DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces Carefully consider wind and air currents when positioning generator Failure to follow proper safety precautions may void manufacturer s warranty Do not operate or store the generator in rain snow or wet weather Using a generator or electrical appliance in wet conditions such as rai...

Страница 15: ...r power from utility power and must comply with all applicable laws and codes NOTE Operation Starting the Engine Cont d Economy Control Switch The Economy Control switch can be activated in order to minimize fuel consumption and noise while operating the unit during times of reduced electrical output allowing the engine speed to idle during periods of non use The engine speed automatically returns...

Страница 16: ...ce and cause a potential fire hazard WARNING Do not operate a device while it is plugged in to the 12V DC outlet Prolonged exposure to engine exhaust can cause serious injury or death WARNING 12V DC Outlet Battery Charging 1 Before connecting the battery charging cable to a battery that is installed in a vehicle disconnect the vehicle battery ground cable from the negative battery terminal 2 Plug ...

Страница 17: ... by adjusting the engine At high altitudes increased exhaust emissions can also result due to the increased enrichment of the air fuel ratio Other high altitude issues can include hard starting increased fuel consumption and spark plug fouling To alleviate high altitude issues other than the natural power loss Champion Power Equipment can provide a high altitude carburetor main jet The alternative...

Страница 18: ...ine at 1 877 338 0999 NOTE Maintenance replacement or repair of emission control devices and systems may be performed by any non road engine repair establishment or individual NOTE Never operate a damaged or defective generator WARNING Tampering with the factory set governor will void your warranty WARNING Improper maintenance will void your warranty WARNING Oil Cont d 0 7 0 8 mm 0 028 0 031 in On...

Страница 19: ...ced owners or Champion Power Equipment certified dealers Maintenance and Storage Every 8 hours or daily Check oil level Clean around air intake and muffler First 5 Hours Change oil Every 50 hours or every season Clean air filter Change oil if operating under heavy load or in hot environments Every 100 hours or every season Change oil Clean Adjust spark plug Check Adjust valve clearance Clean spark...

Страница 20: ...clog the carburetor if it isn t used or drained within 2 weeks Long Term Storage over 1 year For storage over 1 year the fuel tank and carburetor must be completely drained of gasoline 1 Be sure all appliances are disconnected from the generator 2 Add a properly formulated fuel stabilizer to the fuel tank 3 Run the generator for 10 minutes so the treated fuel cycles through the fuel system and car...

Страница 21: ...cess involves technically advanced tasks For assistance please call our Technical Support line at 1 877 338 0999 If the fuel tank and carburetor were properly emptied of all fuel prior to the generator being stored follow the below steps when removing from storage 1 Add fuel to the generator according to Add Fuel 2 With the engine switch in the OFF position turn the fuel valve to the ON position A...

Страница 22: ...ase reference the following chart for recommended oil types for use in the generator SPECIFICATIONS An Important Message About Temperature Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40 C 104 F When your product is needed your product may be operated at temperatures ranging from 15 C 5 F to 50 C 122 F for short periods If the p...

Страница 23: ... BLACK BLUE GREEN RED WHITE Br WHITE BLUE GREEN YELLOW WHITE GREEN BROWN BLACK WHITE B W W L G Y W G GENERATOR ENGINE G RECEPTACLE AC COIL SUB COIL W B W O O B W C W Y O Y L C B Y Y R R R Y Y R W B L TCI UNIT R R G Y G Y G Y C CARNATION A AMETHYST O ORANGE OUTPUT PANEL Y 120V 5 20R R W R R R W G Y B B G B O O W L C C C 120V L5 30R G Y CIRCUIT BREAKER 20A CIRCUIT BREAKER 30A R W Red Black W R FUSE ...

Страница 24: ...9 60 61 62 63 64 65 66 67 68 69 71 73 72 75 76 77 79 80 83 84 85 86 87 88 89 90 91 92 93 94 95 6 7 97 98 99 100 101 102 103 105 106 107 108 74 78 109 110 13 104 48 2 2 2 15 5 5 7 7 11 32 45 45 46 73 38 44 38 22 96 33 139 73 81 82 140 111 112 113 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 29 30 31 31 31 31 30 141 114 114 70 18 19 ...

Страница 25: ... x Ø19 3 x 8 2 52 1 5789 0612 1 Flange Bolt M6 x 12 Black 4 53 83 200704 02 2 Bracket Right Black 1 Part Number Description Qty 54 2 03 001 Bushing Ø13 3 x Ø19 3 x 2 2 55 2 03 002 Washer Ø13 x Ø20 x 2 5 2 56 2 08 002 Bolt M8 x 28 2 57 83 200701 04 2 Handle Right Black 1 58 2 02 002 Nut M6 T Style 2 59 83 200705 01 2 Handle Upper Black 1 60 83 200705 02 2 Handle Lower Black 1 61 1 9074 3 0512 1 Scr...

Страница 26: ...4 122 100387 21 10 Wire Assembly 1 123 83 210002 06 Control Box 1 124 122 210003 01 Grommet 1 125 1 9074 4 0512 Screw Washer Assembly M5 x 12 2 126 1 9074 1 0535 Screw Washer Assembly M5 x 35 1 127 5 1210 930 30 amp Circuit Breaker Push Button 1 128 5 1210 920 20 amp Circuit Breaker Push Button 1 129 1 818 0514 3 Screw M5 x 14 Green 2 130 83 210016 00 Speed Limiter 1 131 5 1120 023 Receptacle L5 3...

Страница 27: ...24 100387 ENGLISH PAGE INTENTIONALLY LEFT BLANK ...

Страница 28: ...75 74 73 48 49 50 51 52 54 56 57 58 59 62 61 63 64 66 68 69 72 33 32 29 30 28 26 25 47 46 45 44 43 42 41 40 38 37 36 95 92 99 98 91 90 89 88 24 23 21 20 19 18 17 16 15 14 13 12 1 2 3 4 5 6 7 8 9 10 11 39 34 60 78 79 80 83 84 55 5 5 22 93 94 27 35 103 102 101 67 65 70 71 100 31 53 35 ...

Страница 29: ... 08 037 Bolt M10 1 25 25 Drain 1 52 83 030009 01 Gasket Cylinder Head 1 53 2 04 003 Dowel Pin Ø10 x 14 2 54 83 040006 01 Valve Exhaust 1 55 83 040002 01 Valve Intake 1 56 2 01 017 Stud Bolt M6 x 32 2 57 83 010100 01 Cylinder Head 1 58 2 15 002 Spark Plug F6RTC 1 Part Number Description Qty 59 83 040017 01 Oil Seal Valve 1 60 83 040004 01 Guide Plate Push Rod 1 61 1 5789 0865 Flange Bolt M8 x 65 2 ...

Страница 30: ... proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected device is defective Replace defective device Circuit breaker is open R...

Страница 31: ...equired to be performed at a facility or by a person authorized by CPE Other Exclusions This warranty excludes Cosmetic defects such as paint decals etc Wear items such as filter elements o rings etc Accessory parts such as starting batteries and storage covers Failures due to acts of God and other force majeure events beyond the manufacturer s control Problems caused by parts that are not origina...

Отзывы: