background image

100165 - 7500W DUAL FUEL ELECTRIC START GENERATOR

ASSEMbLY

15

-20

0

20

40

60

Ambient temperature

Recommended Engine Oil Type

80

100

120

-28.9

°F
°C

-17.8

-6.7

4.4

15.6

26.7

37.8

48.9

10W-30

5W-30 Full Synthetic

10W-40

5W-30

1.  Place the generator on a flat, level surface.

2.  Remove oil fill cap/dipstick to add oil.

3.  Using a funnel, add up to 37.2 fl. oz. (1100 ml) of oil (included) 

and replace oil fill cap/dipstick. DO NOT OVERFILL.

4.  Check engine oil level at every use and add as needed.

MAX

OIL DIP STICK

 

NOTICE

Once oil has been added, a visual check should show oil about 
1-2 threads from running out of the fill hole.

When using the dipstick to check oil level, DO NOT screw in 
the dipstick while checking.

 

NOTICE

Check oil level often during the break-in period. Refer to the 
Maintenance section for recommended service intervals.

 

CAUTION

This engine is equipped with a low oil shut-off and will stop 
when the oil level in the crankcase falls below the threshold 
level.

 

NOTICE

The first 5 hours of run time are the break-in period for the 
unit. During the break in period stay at or below 50% of the 
running watt rating and vary the load occasionally to allow 
stator windings to heat and cool. Adjusting the load will also 
cause engine speed to vary slightly and help seat piston rings. 
After the 5 hour break-in period, change the oil.

 

NOTICE

Synthetic oil may be used after the 5 hour initial break-in 
period. Using synthetic oil does not decrease the recommended 
oil change interval. Full synthetic 5W-30 oil will aid in starting 
in cold ambient < 41º F (5º C) temperatures.

Add Fuel: Gasoline

 

DANGER

Gasoline vapors are highly flammable and extremely explosive.

DO NOT light or smoke cigarettes. Fire or explosion can cause 
severe burns or death. 

Only fill or drain fuel outdoors in a well-ventilated area. 
DO NOT pump gasoline directly into the generator. Use an 
approved container to transfer the fuel to the generator. 

Never use a gasoline container, gasoline tank, or any other fuel 
item that is broken, cut, torn or damaged.

DO NOT overfill the gasoline tank. Always keep fuel away from 
sparks, open flames, pilot lights, heat and other sources of 
ignition.

Use clean, fresh, regular unleaded gasoline with a minimum 
octane rating of 87 and an ethanol content of 10% or less by 
volume. 

y b c

DO NOT mix oil with gasoline.

1.  Remove the gasoline cap.

2.  Slowly add gasoline to the tank. Tank is full when gasoline 

reaches red circle on screen. DO NOT OVERFILL. Gasoline can 
expand after filling. A minimum of ¼ in. (6.4 mm) of space left 
in the tank is required for gasoline expansion, although more 
than ¼ in. (6.4 mm) is recommended. Gasoline can be forced 
out of the tank as a result of expansion if overfilled, and can 
affect the stable running condition of the generator. 

Содержание 100165

Страница 1: ...ore operating the product Failure to do so could result in serious injury This manual should remain with the product Specifications descriptions and illustrations in this manual are as accurate as kno...

Страница 2: ...all carbon monoxide risks you ll be better prepared to protect your family from this colorless oderless threat CARBON MONOXIDE SAFETY THE BIG PICTURE KNOW THE SYMPTOMS Headache Nausea Shortness of br...

Страница 3: ...Stopping the Engine 22 Moving the Generator 22 Operation at High Altitude 22 Maintenance 23 Cleaning the Generator 23 Changing the Engine Oil 23 Cleaning and Adjusting the Spark Plug 24 Cleaning the A...

Страница 4: ...very effort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and t...

Страница 5: ...Rotating parts can entangle hands feet hair clothing and or accessories Traumatic amputation or severe laceration can result Keep hands and feet away from rotating parts Tie up long hair and remove je...

Страница 6: ...or laceration When starting engine pull the recoil cord slowly until resistance is felt and then pull rapidly to avoid kickback DO NOT start or stop the engine with electrical devices plugged in and...

Страница 7: ...y and all LPG away from skin at all times When adding or removing gasoline DO NOT light or smoke cigarettes Turn the generator off and let cool for at least two minutes before removing the gasoline ca...

Страница 8: ...by or for outside parties without the explicit consent of Champion Power Equipment Fuel C WARNING DO NOT TOUCH Exhaust gases muffler and engine components are extremely HOT and cause burns Operation o...

Страница 9: ...ents before operation Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Improper connections to a building can allow current to backfeed into u...

Страница 10: ...Tank 6 gal 22 9 L 2 Choke Used to start the engine 3 Air Filter Protects the engine by filtering dust and debris from the intake air 4 Never Flat Wheels 9 5 in 24 1 cm 5 Recoil Starter Used to manual...

Страница 11: ...ables starting electrically 6 Ground Terminal Consult an electrician for local grounding regulations 7 Circuit Breakers Push Reset Protects the generator against electrical overloads RECEPTACLES A W 1...

Страница 12: ...tal run time Push SELECT button on right side of gauge to display different modes MODE DESCRIPTION Voltage V Output voltage of the generator Example 120 volts V Hz H 120 Frequency Hz Output frequency...

Страница 13: ...ngine Oil 37 2 fl oz 1100 ml Oil Funnel 1 Assembly Parts Wheels 9 5 in 24 1 cm Never Flat Wheel A 2 Roll Pin B 2 Large R clip C 2 Support Leg Support Leg with Vibration Mounts D 1 Flange Bolt M8 16 E...

Страница 14: ...attach the second wheel Install the Support Leg 1 Attach the support leg to the generator frame with flange bolts and flange lock nuts 2 Slowly tip the generator back down so that it rests on the whe...

Страница 15: ...ston rings After the 5 hour break in period change the oil NOTICE Synthetic oil may be used after the 5 hour initial break in period Using synthetic oil does not decrease the recommended oil change in...

Страница 16: ...oline alone These ethanol blends can eventually separate leaving water or a watery goo in the tank fuel valve and carburetor The compromised gasoline can be drawn into the carburetor and cause damage...

Страница 17: ...available Keep cylinders away from heat and ventilated when in a vehicle WARNING If there is a strong smell of LPG Close valve on the cylinder Check all connections for leaks by wetting the fittings w...

Страница 18: ...r for storage purposes Failure to follow proper safety precautions may result in personal injury damage to the generator and void the manufacturer s warranty WARNING During operation the muffler and e...

Страница 19: ...engine move the choke to 75 of the CHOKE position 3 Pull the recoil cord slowly until resistance is felt and then pull rapidly 4 Do not over choke As soon as engine starts move the choke to the RUN p...

Страница 20: ...g when the oil level falls below a critical threshold NOTICE Accumulation of frost on LPG cylinder and regulators is common during operation and normally is not an indication of a problem As LPG vapor...

Страница 21: ...at the same time 2 Total the running watts of these items This is the amount of power you need to keep your items running 3 Identify the highest starting wattage of all devices identified in step 1 Ad...

Страница 22: ...NOTICE If the engine will not be used for a period of two 2 weeks or longer please see the Storage section for proper engine and fuel storage Moving the Generator CAUTION NEVER lift or carry the gene...

Страница 23: ...ur responsibilities for service as stated in the Emission Control Warranty Statement of this manual The owner operator is responsible for all periodic maintenance Complete all scheduled maintenance in...

Страница 24: ...ll result in poor engine performance NOTICE Federal and local laws and administrative requirements indicate when and where spark arrestors are required When ordered spark arrestors are required for op...

Страница 25: ...an adjust spark plug Clean spark arrestor Clean fuel valve filter EVERY 250 HOURS Clean combustion chamber Check adjust valve clearance EVERY 3 YEARS Replace fuel line Replace LPG hose To be performed...

Страница 26: ...o an appropriate container Use a funnel and appropriate hose if necessary under the carburetor drain bolt to avoid spillage 4 When gasoline stops flowing from the carburetor replace and tighten the ca...

Страница 27: ...6 7 4 4 15 6 26 7 37 8 48 9 10W 30 5W 30 Full Synthetic 10W 40 5W 30 NOTICE Temperature will affect engine oil and engine performance Change the type of engine oil used based on temperature shown in t...

Страница 28: ...r level Place generator on a flat level surface Clogged spark arrestor Clean spark arrestor Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Conne...

Страница 29: ...load Review load and adjust See Connecting Electrical Loads Faulty power cords or device Check for damaged bare or frayed wires Replace defective device Circuit breaker still too hot Let unit sit for...

Страница 30: ...roperly or connected incorrectly to any electrical component Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by CPE Other...

Страница 31: ...our exhaust emission control system may be fuel injection system the ignition system catalytic converter and other exhaust emission related assemblies Where a warrantable condition exits CPE will repa...

Страница 32: ...d for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CPE according...

Страница 33: ...Mounting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other p...

Отзывы: