background image

Safety Rules 

4  

Rev 

CSA40017-20070612

 

 DANGER 

Fuel and fuel vapors are highly flammable and 
extremely explosive. 
Fire or explosion can cause severe burns or 
death.  

Unintentional startup can result in entanglement, 
traumatic amputation or laceration.  

When adding or removing fuel 

Turn the generator off and let it cool for at least 
two minutes before removing the fuel cap. 
Loosen the cap slowly to relieve pressure in the 
tank. 
Only fill or drain fuel outdoors in a well-ventilated 
area. 
DO NOT overfill the fuel tank. 
Always keep fuel away from sparks, open flames, 
pilot lights, heat and other sources of ignition. 
DO NOT light or smoke cigarettes. 

When starting the generator 

DO NOT attempt to start a damaged generator.  
Make certain that the gas cap, air filter, spark 
plug, fuel lines and exhaust system are properly 
in place. 
Allow spilled fuel to evaporate fully before 
attempting to start the engine. 
Make certain that the generator is resting firmly 
on level ground. 

When operating the generator: 

DO NOT move or tip the generator during 
operation. 
DO NOT tip the generator or allow fuel or oil to 
spill. 

When transporting or servicing the 

generator: 

Make certain that the fuel shutoff valve is in the 
off position and the fuel tank is empty. 
Disconnect the spark plug wire. 

When storing the generator: 

Store away from sparks, open flames, pilot lights, 
heat and other sources of ignition. 

 

 
 

 WARNING 

Rapid retraction of the starter cord will pull hand 
and arm towards the engine faster than you can 
let go. 

Unintentional startup can result in entanglement, 
traumatic amputation or laceration.  

Broken bones, fractures, bruises or sprains could 
result. 

When starting engine, pull the starter cord slowly 
until resistance is felt and then pull rapidly to 
avoid kickback. 
DO NOT start or stop the engine with electrical 
devices plugged in. 

 

 CAUTION 

Exceeding the generator’s running capacity can 
damage the generator and/or electrical devices 
connected to it 

DO NOT overload the generator. 
Start the generator and allow the engine to 
stabilize before connecting electrical loads. 
Connect electrical equipment in the off position, 
and then turn them on for operation.

 

Turn electrical equipment off and disconnect 
before stopping the generator.

 

DO NOT tamper with the governed speed. 

 

DO NOT modify the generator in any way.

 

 

 CAUTION  

Improper treatment or use of the generator can 
damage it, shorten its life and void your 
warranty. 

Use the generator only for intended uses.

 

Operate only on level surfaces.

 

DO NOT expose generator to excessive moisture, 
dust, or dirt.

 

DO NOT allow any material to block the cooling 
slots.

 

If connected devices overheat, turn them off and 
disconnect them from the generator.

 

DO NOT use the generator if:

 

 

Electrical output is lost

 

 

Equipment sparks, smokes or emits flames

 

 

Equipment vibrates excessively

 

 

Содержание CSA40017

Страница 1: ...CSA40017 Rev CSA40017 20070612 10006 Santa Fe Springs Road Santa Fe Springs CA 90670 USA Made in China 7800 Peak Watts 6500 Running Watts PORTABLE GENERATOR Owner s Manual and Operating Instructions...

Страница 2: ......

Страница 3: ...11 Wattage Reference Chart 11 Maintenance 12 Engine Maintenance 12 Oil 12 Spark Plugs 12 Air Filter 12 Spark Arrester if installed 13 Cleaning 13 Adjustments 13 Maintenance Schedule 13 Generator Main...

Страница 4: ......

Страница 5: ...s accessories designed to help you get the most from your purchase To find out more about our covers power cables and storm kits please visit our web site at www championpowerequipment com This Bookle...

Страница 6: ...imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or ser...

Страница 7: ...wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator produces powerful voltage DO NOT touch bare wires or receptacles DO NOT use electrical cords that a...

Страница 8: ...re away from sparks open flames pilot lights heat and other sources of ignition WARNING Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go Uninte...

Страница 9: ...l Valve 2 Turn this valve to the On position to supply fuel to the engine Choke 3 Used to start the engine Air Cleaner 4 Protects the engine by filtering dust and debris from the intake air Recoil Sta...

Страница 10: ...anel LED lighting Parameter Button 8 Push button selector for the Intelligauge 120 V 30 A Twist Lock 9 protected by a 30 A circuit breaker This receptacle powers 120 Volt AC 60 Hz single phase loads r...

Страница 11: ...ips with the following parts Wheel Kit Axle 1 piece 10 Solid Wheel 2 pieces Support Leg 1 piece Vibration Mounts 2 pieces Bolt Kit Wheel Retaining Pins 2 pieces Flat Washers 2 pieces Cap Screws and Nu...

Страница 12: ...efully bend the legs of the cotter pin back around the axle 7 Repeat steps 3 6 to attach the second wheel Install the Support Leg 1 Attach the rubber vibration mount to the support leg with a cap scre...

Страница 13: ...y spilled fuel CAUTION Use regular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately below the top of the tank to allow for fuel expansion DO...

Страница 14: ...in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations 2 Obtain an Uninterruptible Power Supply UPS device Most UPS devices come with a...

Страница 15: ...rator with no electrical load attached 2 Allow the engine to run for several minutes to stabilize 3 Plug in and turn on the first item It is best to attach the item with the largest load first 4 Allow...

Страница 16: ...4 Remove oil fill cap dipstick to add oil 5 Add 1 16 qt 1 1 L of oil and replace oil fill cap dipstick 6 Dispose of used oil at an approved waste management facility Spark Plugs 1 Remove the spark plu...

Страница 17: ...ing in adverse conditions Contact our help line at 1 877 338 0999 to locate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenance needs Every 8 hours o...

Страница 18: ...m the fuel line and carburetor to prevent gum from forming 4 Add a fuel stabilizer into the fuel tank 5 Change the oil 6 Remove the spark plug and pour about ounce of oil into the cylinder Crank the e...

Страница 19: ...ty is 6 5 US gallons 25 L Use regular unleaded gasoline with a minimum octane rating of 85 Oil Oil capacity is 1 16 qt 1 1 L Spark Plugs Your generator comes equipped with a long reach plug 18mm Inter...

Страница 20: ...Specifications 16 Rev CSA40017 20070612 Parts Diagram...

Страница 21: ...10 7 24 ST168F 1152032 CSA Terminal 1 25 ST05F 1152031 CSA AVR 1 26 ST05FD 1152035 CSA Brush Assembly 1 27 ST05FD 1152032 End Cover 1 28 GB5789 FB6 179 Flange Bolt M6 179 4 29 ST05FD 1152001 Stator C...

Страница 22: ...Case 1 81 ST188FD 1090002 Air Cleaner Seal 1 82 GB41 N 5 Nut M5 6 83 ST188FD 1090003 Separator 1 84 ST188FD 1090004 Element 1 85 ST188FD 1090200 Air Cleaner Cover 1 86 ST188FD 1080200 Control Assembly...

Страница 23: ...16 Washer 16 2 116 GBT CP3 2 40 Cotter Pin 3 2 40 2 117 ST188FD 1750002 C1 Red Battery Wire 1 118 ST188FD 1750002 C2 Black Battery Wire 1 119 ST188FD 1751002 Jacket 3 120 GB41 N 6 Nut M6 2 121 ST188FD...

Страница 24: ...Wiring Diagram 20 Wiring Diagram...

Страница 25: ...aded Review load and adjust See Power Management Generator cannot supply enough power or overheating Insufficient ventilation Check for air restriction Move to a well ventilated area Cable not properl...

Страница 26: ...whole Installation Use and Maintenance This warranty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the ge...

Страница 27: ...Notes Rev CSA40017 20070612 23 Notes...

Отзывы: