background image

  

Assembly 

Rev 41331-20110330 English                                                                                               9

Install the Spark Arrester 

Insert the spark arrester screen into the 

muffler outlet. Secure the spark arrester by 

placing the cover plate over the end of the 

screen, with the lettering facing outward.  

 

 

 

Secure the cover plate with the two screws 

and lock washers provided with the spark 

arrester kit. 

  NOTE 

Federal and local laws and administrative 
requirements indicate when and where spark 
arresters are required. When ordered, spark 
arresters are required for operation of this 
generator in National Forest lands. In California, 
this generator must not be used on any forest-
covered land, brush-covered land, or grass-
covered land unless the engine is equipped with 
a spark arrester. 
 

 

 

CAUTION

 

Failure to install the spark arrester may result in 
an increased risk of fire.. 

 

 

Add Engine Oil 

 CAUTION 

DO NOT attempt to crank or start the engine 
before it has been properly filled with the 
recommended type and amount of oil. Damage 
to the generator as a result of failure to follow 
these instructions will void your warranty. 
 

1.

 

Place the generator on a flat, level 

surface. 

2.

 

Remove oil fill cap/dipstick to add oil. 

 

 

 

3.

 

Add 1.16 qt (1.1 L) of oil and replace oil 

fill cap/dipstick.  See “Specifications” for 

oil recommendations based on 

operating conditions. 

4.

 

Check engine oil level daily and add as 

needed. 

 

CAUTION 

The engine is equipped with a low-oil-shutoff and  
will stop when the oil level in the crankcase falls 
below the threshold level. 
 

 

  NOTE 

Check oil often during the break-in period. Refer 
to the Maintenance section for recommended 
service intervals. 
 

 

  NOTE 

The generator rotor has a sealed, pre-lubricated 
ball bearing that requires no additional lubrication 
for the life of the bearing. 
 

 

Add Fuel 

1.

 

Use clean, fresh, regular unleaded fuel 

with a minimum octane rating of 85.  

2.

 

DO NOT mix oil with fuel. 

3.

 

Clean the area around the fuel cap.  

4.

 

Remove the fuel cap 

5.

 

Slowly add fuel to the tank. DO NOT 

overfill. Allow approximately ¼ inch of 

space for fuel expansion. 

6.

 

Screw on the fuel cap and wipe away any 

spilled fuel. 

Содержание 41331

Страница 1: ...Fe Springs Road Santa Fe Springs CA 90670 USA Made in China 7000 Peak Watts 6000 Running Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual Owne...

Страница 2: ......

Страница 3: ...ence Chart 1 2SHUDWLRQ DW LJK OWLWXGH 3 Maintenance 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 14 Spark Arrester 14 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintena...

Страница 4: ......

Страница 5: ...pment Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from your purchase To find out more about our covers power cables and storm kits please...

Страница 6: ...n imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or s...

Страница 7: ...rotating parts Tie up long hair and remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator pro...

Страница 8: ...hutoff valve is in the off position and the fuel tank is empty Disconnect the spark plug wire When storing the generator Store away from sparks open flames pilot lights heat and other sources of ignit...

Страница 9: ...apacity fuel tank 2 Fuel Valve Turn this valve to the On position to supply fuel to the engine 3 Choke Lever Used to start the engine 4 Air Cleaner Protects the engine by filtering dust and debris fro...

Страница 10: ...120 240 V 30 A Twist Lock protected by a 30 A push to reset circuit breaker on each 120 Volt leg of the receptacle This receptacle powers 240 Volt AC 60 Hz single phase loads requiring up to 25 A or 6...

Страница 11: ...eces Vibration Mounts 2 pieces Handle Assembly 1 Set Support Leg 1 piece Handle Locking pins 2 pieces Bolt Kit Flat Washers 2 pieces Cap Screws and Nuts 10 sets Axle bushing 2 pieces Washers 4 pieces...

Страница 12: ...2 Slide the M10x125 wheel bolt through the washer axle bushing and wheel 3 Slide the bolt through the mount point on the frame 4 Fasten securely with the M10 nut 5 Repeat steps 2 4 to attach the seco...

Страница 13: ...ommended type and amount of oil Damage to the generator as a result of failure to follow these instructions will void your warranty 1 Place the generator on a flat level surface 2 Remove oil fill cap...

Страница 14: ...ling the fuel tank Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock WARNING Failure to properly ground the generator can result in electric s...

Страница 15: ...e equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Starting the Engine 1 Make certain the generat...

Страница 16: ...ad for several minutes to stabilize internal temperatures of the engine and generator 3 Turn the ignition switch to the Off position 4 Turn the fuel valve to the Off position Do Not Overload Generator...

Страница 17: ...um altitude can damage the engine For operation at lower elevations the standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emi...

Страница 18: ...cap dipstick to add oil 5 Add 1 16 qt 1 1 L of oil and replace oil fill cap dipstick 6 Dispose of used oil at an approved waste management facility Spark Plugs 1 Remove the spark plug cable from the...

Страница 19: ...Power Equipment certified service dealer for your generator or engine maintenance needs Every 8 hours or daily Check oil level Clean around air intake and muffler First 5 Hours Change oil Every 50 ho...

Страница 20: ...rom the fuel line and carburetor to prevent gum from forming 4 Add a fuel stabilizer into the fuel tank 5 Change the oil 6 Remove the spark plug and pour about ounce of oil into the cylinder Crank the...

Страница 21: ...lons 25 L Use regular unleaded gasoline with a minimum octane rating of 85 Oil Oil capacity is 1 16 qt 1 1 L Spark Plugs Your generator comes equipped with a 3 4 19 mm long reach plug Use the spark pl...

Страница 22: ...Specifications 18 Rev 41331 20110330 English Parts Diagram...

Страница 23: ...52030 CPE AVR 1 22 ST02FD 02100008 Brush Support Plate 1 23 ST05FD 1152035 Brush Assembly 1 24 ST05FD 1152002 End Cover 1 25 ST05FD 1152004 5 Flange Bolt M6 179 4 26 ST05FD 1152003 5 Stator Cover 1 27...

Страница 24: ...sher 8 2 76 GB6175 M8 Nut M8 2 77 GB5789 M6 12 Flange Bolt M6 12 2 78 ST168FD 1100003 CARB SAI Valve Washer 1 79 ST168FD 1100300 CARB SAI Valve 1 80 ST188FD 1100002 CARB Muffler 1 81 ST188FD 1100103 M...

Страница 25: ...ank Wing 2 110 ST188FD 1744002 T Wheel 2 111 ST36QXG 03000002 Bushing 10 5 69 5 2 112 GB96 10 Washer 10 2 113 GB5782 M10 125 Bolt M10 125 2 114 ST02FD 1152010 5 Grounding Wire 1 115 GB97 1 6 Washer 6...

Страница 26: ...Specifications 22 Rev 41331 20110330 English Wiring Diagram...

Страница 27: ...overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly conne...

Страница 28: ...n Use and Maintenance This warranty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits...

Страница 29: ...S EMISSION CONTROL SYSTEM WARRANTY COVERAGE This emission control system is warranted for two years subject to provisions set forth below If during the warranty period emission related part on your e...

Страница 30: ...s scheduled for replacement as required maintenance in the Owner s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior...

Страница 31: ...ting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof...

Отзывы: