background image

3

  

REV 41135-20140115

ENGLISH

 

41135

SAFETy RULES

Generator exhaust contains carbon monoxide, a 
colorless, odorless, poison gas. Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death. If you start to feel dizzy or weak, get to fresh 
air immediately.

Operate generator outdoors only in a well ventilated 
area.
DO NOT operate the generator inside any building, 
including garages, basements, crawlspaces and 
sheds, enclosure or compartment, including the 
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings.
DANGER CARBON MONOXIDE: using a generator 
indoors

 CAN KILL YOU IN MINUTES.

DANGER

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories. 
Traumatic amputation or severe laceration can result.

Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught.

DANGER

Generator produces powerful voltage.

DO NOT touch bare wires or receptacles.

DO NOT use electrical cords that are worn, damaged 

or frayed.

DO NOT operate generator in wet weather.

DO NOT allow children or unqualified persons to 

operate or service the generator

Use a ground fault circuit interrupter (GFCI) in damp 

areas and areas containing conductive material such 

as metal decking.

Use approved transfer equipment to isolate generator 

from your electric utility and Notify your utility 

company before connecting your generator to your 

power system.

DANGER

Sparks can result in fire or electrical shock.

When servicing the generator:

Disconnect the spark plug wire and place it where it 

cannot contact the plug.

DO NOT check for spark with the plug removed.

Use only approved spark plug testers.

WARNING

Running engines produce heat. Severe burns can 

occur on contact. 

Combustible material can catch fire on contact.

DO NOT touch hot surfaces.

Avoid contact with hot exhaust gases.

Allow equipment to cool before touching.

Maintain at least 3 ft. (91.4 cm) of clearance on all 

sides to ensure adequate cooling.

Maintain at least 5 ft. (1.5 m) of clearance from 

combustible materials.

WARNING

Medical and Life Support Uses.

In case of emergency, call 911 immediately.
NEVER use this product to power life support 
devices or life support appliances.
NEVER use this product to power medical devices 
or medical appliances.
Inform your electricity provider immediately if you 
or anyone in your household depends on electrical 
equipment to live.
Inform your electrical provider immediately if a 
loss of power would cause you or anyone in your 
household to experience a medical emergency.

WARNING

The engine exhaust from this product contains 
chemicals known to the state of California to cause 
cancer, birth defects, or other reproductive harm.

WARNING

Read this manual thoroughly before operating your 
generator. Failure to follow instructions could result 
in serious injury or death.

WARNING

Содержание 41135

Страница 1: ...0670 USA 1 877 338 0999 www championpowerequipment com SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 41135 20140115 41135 MODEL NUMBER warranty_ba...

Страница 2: ...eded your product may be operated at temperatures ranging from 15 C 5 F to 50 C 122 F for short periods If the product is exposed to temperatures outside this range during storage it should be brought...

Страница 3: ...aintenance 14 Oil 14 Spark Plugs 14 Air Filter 14 Spark Arrester 15 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintenance 16 Storage 16 Generator Storage 16 Specifications 17 Engine...

Страница 4: ...information available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most fro...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can re...

Страница 7: ...ay create sparks that can start fires around dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention require...

Страница 8: ...ank 5 9 gallon 22 4 L capacity fuel tank 2 Choke Used to start the engine 3 Fuel Valve Turn this valve to the ON position to supply fuel to the engine 4 Air Cleaner Protects the engine by filtering du...

Страница 9: ...display alternator output voltage 4 120 240V AC 30 Amp Twist Lock Receptacle NEMA L14 30R May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz e...

Страница 10: ...ith the following parts Wheel Kit 8 in Wheel 2 Flange Bolt M10x105 for Wheel 2 Bushing 2 Flat Washer 10 2 Nut M10 2 Handle 1 Support Leg w Vibration Mounts 1 Flange Bolt M8x45 for Handle 2 Flange Bolt...

Страница 11: ...the following tools to install the wheels 17 mm wrench OR adjustable wrench not included Socket wrench with a 16 mm socket not included Pliers not included 1 Before adding fuel and oil tip the generat...

Страница 12: ...ubricated ball bearing that requires no additional lubrication for the life of the bearing NOTE Add Engine Oil Cont d 2 Remove oil fill cap dipstick to add oil 3 Add 1 2 qt 1 1 L of oil and replace oi...

Страница 13: ...y manufacture s warranty It is advisable to always shut off the fuel supply run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days NOTE Add Fuel 1...

Страница 14: ...ioning generator Failure to follow proper safety precautions may void manufacturer s warranty Do not operate or store the generator in rain snow or wet weather Using a generator or electrical applianc...

Страница 15: ...l devices plugged in or turned on 2 Let the generator run at no load for several minutes to stabilize internal temperatures of the engine and generator 3 Turn the Fuel Valve to the OFF position 4 Let...

Страница 16: ...ith the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING Operation at High Altitude The density of air at high altitude is...

Страница 17: ...ate in clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove the spar...

Страница 18: ...he end of the spark arrester to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if i...

Страница 19: ...s are disconnected from the generator 3 Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor 4 Turn the fuel valve to the Off position 5 Let the genera...

Страница 20: ...g the valve adjustment procedure is on www championpowerequipment com Spark Plugs OEM spark plug NHSP F6RTC Replacement spark plug NGK BPR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 m...

Страница 21: ...REV 41135 20140115 18 41135 ENGLISH Wiring Diagram Specifications...

Страница 22: ...25 26 27 28 29 30 31 32 33 34 36 38 39 40 41 42 43 44 40 45 46 47 39 40 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 50 65 66 67 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 91 68 92...

Страница 23: ...1 16674 0516 Flange Bolt M5 16 3 51 152 190200 04 AVR 5KW CPE 1 52 152 190002 00 End Housing 1 Part Number Description Qty 53 2 08 029 Flange Bolt M6 165 4 54 151 191002 00 Stator Cover 1 55 2 08 030...

Страница 24: ...3 102 101 83 10 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 22 23 24 25 26 27 28 29 31 32 33 12 34 28 35 36 21 37 39 40 41 42 44 45 46 47 48 49 50 51 12 52 53 55 56 57 58 59 60 63 64 66 67 68 69 7...

Страница 25: ...ylinder Head 1 54 2 01 006 Stud Bolt M8 35 2 55 2 15 002 F6RTC Spark Plug F6RTC 1 Part Number Description Qty 56 2 08 014 Flange Bolt M10 80 4 57 46 020002 00 Gasket Cylinder Head Cover 1 58 46 021000...

Страница 26: ...e to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient venti...

Страница 27: ...labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any elec...

Страница 28: ...and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EMISSION CONTROL S...

Страница 29: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 30: ...rburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of original pur...

Отзывы: