background image

REV 41135-20140115  

14

41135

 

ENGLISH

The owner/operator is responsible for all periodic 
maintenance.

Complete all scheduled maintenance in a timely manner. 
Correct any issue before operating the generator.

Never operate a damaged or defective generator.

Tampering with the factory set governor will void 
your warranty.

Engine Maintenance

To prevent accidental starting, remove and ground spark 
plug wire before performing any service.

Oil

Change oil when the engine is warm. Refer to the oil 
specification to select the proper grade of oil for your 
operating environment.
1.  Remove the oil drain plug with a 15 mm socket and 

extension.

2.  Allow the oil to drain completely.
3.  Replace the drain plug.
4.  Remove oil fill cap/dipstick to add oil.
5.  Add 1.2 qt. (1.1 L) of oil and replace oil fill 

cap/dipstick. DO NOT OVERFILL.

6.  Dispose of used oil at an approved waste 

management facility.

Air Filter

1.  Remove the snap-on cover holding the air filter to 

the assembly.

2.  Remove the foam element. 
3.  Wash in liquid detergent and water. Squeeze 

thoroughly dry in a clean cloth.

4.  Saturate in clean engine oil. 
5.  Squeeze in a clean, absorbent cloth to remove all 

excess oil.

6.  Place the filter in the assembly.
7.  Reattach the air filter cover and snap in place.

Spark Plugs

1.  Remove the spark plug cable from the spark plug.
2.  Use the spark plug tool that shipped with your 

generator to remove the plug.

3.  Inspect the electrode on the plug. It must be clean and 

not worn to produce the spark required for ignition.

4.  Make certain the spark plug gap is 0.7 - 0.8 mm or 

(0.028 - 0.031 in.).

5.  Refer to the spark plug recommendation chart when 

replacing the plug.

6.  Carefully thread the plug into the engine.
7.  Use the spark plug tool to firmly install the plug.
8.  Attach the spark plug wire to the plug.

For service or parts assistance, contact our help 
line at 

1-877-338-0999

NOTE

Maintenance, replacement, or repair of emission 
control devices and systems may be performed 
by any non-road engine repair establishment or 
individual.

NOTE

WARNING

WARNING

Improper maintenance will void your warranty.

WARNING

Oil Cont’d.

0.7 - 0.8 mm

0.028 - 0.031 in.

MAINTENANCE AND STORAGE

Once oil has been added, a visual check should show 
oil about 1-2 threads from running out of the fill hole.
If using the dipstick to check oil level, DO NOT screw 
in the dipstick while checking.

NOTE

Содержание 41135

Страница 1: ...0670 USA 1 877 338 0999 www championpowerequipment com SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 41135 20140115 41135 MODEL NUMBER warranty_ba...

Страница 2: ...eded your product may be operated at temperatures ranging from 15 C 5 F to 50 C 122 F for short periods If the product is exposed to temperatures outside this range during storage it should be brought...

Страница 3: ...aintenance 14 Oil 14 Spark Plugs 14 Air Filter 14 Spark Arrester 15 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintenance 16 Storage 16 Generator Storage 16 Specifications 17 Engine...

Страница 4: ...information available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most fro...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can re...

Страница 7: ...ay create sparks that can start fires around dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention require...

Страница 8: ...ank 5 9 gallon 22 4 L capacity fuel tank 2 Choke Used to start the engine 3 Fuel Valve Turn this valve to the ON position to supply fuel to the engine 4 Air Cleaner Protects the engine by filtering du...

Страница 9: ...display alternator output voltage 4 120 240V AC 30 Amp Twist Lock Receptacle NEMA L14 30R May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz e...

Страница 10: ...ith the following parts Wheel Kit 8 in Wheel 2 Flange Bolt M10x105 for Wheel 2 Bushing 2 Flat Washer 10 2 Nut M10 2 Handle 1 Support Leg w Vibration Mounts 1 Flange Bolt M8x45 for Handle 2 Flange Bolt...

Страница 11: ...the following tools to install the wheels 17 mm wrench OR adjustable wrench not included Socket wrench with a 16 mm socket not included Pliers not included 1 Before adding fuel and oil tip the generat...

Страница 12: ...ubricated ball bearing that requires no additional lubrication for the life of the bearing NOTE Add Engine Oil Cont d 2 Remove oil fill cap dipstick to add oil 3 Add 1 2 qt 1 1 L of oil and replace oi...

Страница 13: ...y manufacture s warranty It is advisable to always shut off the fuel supply run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days NOTE Add Fuel 1...

Страница 14: ...ioning generator Failure to follow proper safety precautions may void manufacturer s warranty Do not operate or store the generator in rain snow or wet weather Using a generator or electrical applianc...

Страница 15: ...l devices plugged in or turned on 2 Let the generator run at no load for several minutes to stabilize internal temperatures of the engine and generator 3 Turn the Fuel Valve to the OFF position 4 Let...

Страница 16: ...ith the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING Operation at High Altitude The density of air at high altitude is...

Страница 17: ...ate in clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove the spar...

Страница 18: ...he end of the spark arrester to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if i...

Страница 19: ...s are disconnected from the generator 3 Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor 4 Turn the fuel valve to the Off position 5 Let the genera...

Страница 20: ...g the valve adjustment procedure is on www championpowerequipment com Spark Plugs OEM spark plug NHSP F6RTC Replacement spark plug NGK BPR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 m...

Страница 21: ...REV 41135 20140115 18 41135 ENGLISH Wiring Diagram Specifications...

Страница 22: ...25 26 27 28 29 30 31 32 33 34 36 38 39 40 41 42 43 44 40 45 46 47 39 40 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 50 65 66 67 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 91 68 92...

Страница 23: ...1 16674 0516 Flange Bolt M5 16 3 51 152 190200 04 AVR 5KW CPE 1 52 152 190002 00 End Housing 1 Part Number Description Qty 53 2 08 029 Flange Bolt M6 165 4 54 151 191002 00 Stator Cover 1 55 2 08 030...

Страница 24: ...3 102 101 83 10 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 22 23 24 25 26 27 28 29 31 32 33 12 34 28 35 36 21 37 39 40 41 42 44 45 46 47 48 49 50 51 12 52 53 55 56 57 58 59 60 63 64 66 67 68 69 7...

Страница 25: ...ylinder Head 1 54 2 01 006 Stud Bolt M8 35 2 55 2 15 002 F6RTC Spark Plug F6RTC 1 Part Number Description Qty 56 2 08 014 Flange Bolt M10 80 4 57 46 020002 00 Gasket Cylinder Head Cover 1 58 46 021000...

Страница 26: ...e to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient venti...

Страница 27: ...labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any elec...

Страница 28: ...and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EMISSION CONTROL S...

Страница 29: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 30: ...rburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of original pur...

Отзывы: