6

110496-1

Model No.

Modelo

Motor Part #

Motor - Nº

HP

CV

Speed

Velocidad

Volts

Voltios

Motor Pulley Part #

Polea Del Motor - Nº

Drive Belt # (Size)

Banda - Nº (Tamaño)

Pump Part #

Bomba - Nº

RWC35, RN35W

110445

1/3

2

115

110271

110225 (4L-470)

110428

WC37, N37W

110445

1/3

2

115

110271

110226 (4L-480)

110428

WC44, N44W

RWC44

110445

1/3

2

115

110272

110215 (4L-560)

110428

WC46, N46W

RWC46, RN46W

110445

1/3

2

115

110272

110215 (4L-560)

110428

WC50, N50W

RWC50, RN50W

110447

1/2

2

115

110273

110215 (4L-560)

110429

Model No.

Modelo

Weight (lbs.)

Peso (libras)

Cabinet Dimensions (in.)

Dimensions De La Caja (pulgadas)

Window Opening Req’d (in.)

Abertura Requerida (pulgadas)

Dry

Seco

Operating

Lleno

Height

Altura

Width

Anchura

Depth

Profundidad

Width

Anchura

Height

Altura

RWC35, RN35W

113

190

30 3/4

31 1/2

21

21 3/4

14 3/4

WC37, N37W

113

190

30 3/4

31 1/2

21

21 3/4

14 3/4

WC44, N44W

RWC44

137

214

34 1/2

34 1/8

28 1/2

21 3/4

14 3/4

WC46, N46W

RWC46, RN46W

152

246

34 1/2

34 1/8

34 1/8

21 3/4

14 3/4

WC50, N50W, 

RWC50, RN50W

155

249

34 1/2

34 1/8

34 1/8

21 3/4

14 3/4

Parts 

Drawing  

/  Dibujo De Piezas

Motor Specifications  /

  Especificaciones Del Motor

General Specifications /

 Especificaciones Generales

Содержание Excel N37W

Страница 1: ...or a combination of both The air is always fresh not stale laden with smoke and odors as happens with refrigerated air conditioning Vea el Espa ol en el interior 110496 1 2 19 www championcooler com M...

Страница 2: ...operating the fan The pump must be on while operating the fan for cooling You may also want the pump turned off at times when just a fan is desired FAN button Pressing this button will cycle the fan t...

Страница 3: ...gged This is for your safety Spring Start Up Oil bearings The blower bearings and cooler motor in this unit should be oiled with a few drops of non detergent 20 30 weight oil once each year The motor...

Страница 4: ...between the front panel and the top pan Line up the two larger holes in the tunnel with the center two holes of the top pan Fig 11 5 Using the screws taken from the top pan secure the tunnel to the un...

Страница 5: ...ginal purchaser only Problem Possible Cause Remedy Failure to start or no air delivery Inadequate air delivery with cooler running Inadequate cooling 1 No electrical power to unit Fuse blown Circuit b...

Страница 6: ...110429 Model No Modelo Weight lbs Peso libras Cabinet Dimensions in Dimensions De La Caja pulgadas Window Opening Req d in Abertura Requerida pulgadas Dry Seco Operating Lleno Height Altura Width Anch...

Страница 7: ...er Flow Assembly Montaje De Desag e 3OA 1 3OA 1 3OA 1 3OA 1 36 House Leg Collar Assembly Montaje De Collar De La Pata 3HL 3 2 3HL 3 2 3HL 1 2 3HL 1 2 37 House Leg Pata 310811 2 310811 2 310811 2 31081...

Страница 8: ...mba por unos cuantos minutos para mojar los filtros antes de poner en marcha el ventilador Los posiciones HIGH COOLy LOWCOOL Ajuste el interruptor a la posici n HIGH COOL o LOW COOL para poner en marc...

Страница 9: ...a que los topes de hule descansen contra el costado de la pared Apriete el tornillo del collar G fig 2 Instalaci n Instalar Las Patas NOTA Si instale la unidad sin el uso del equipo de instalaci n omi...

Страница 10: ...ar n sobre la secci n de centro de la rejilla Deslice la cubierta sobre la rejilla Los clips de la cubierta se encajar n a presi n hacia lugar Para quitar d un tir n con cuidado a la cubierta quit ndo...

Страница 11: ...ete los tornillos D jenlos flojos hasta que el resto del conducto se ha asegura do 6 Alinee los tres agujeros en el fondo del conducto con los agujeros en el panel delante ro Con los tornillos quitado...

Страница 12: ...cuito desac tivado Cable el ctrico da ado 2 Correa muy floja o apretada 3 Motor recalentado Correa muy apretada Cojinetes de la rueda est n secos 4 Motor parado 1 Insuficiente abertura para que salga...

Отзывы: