background image

TIMER TO CLOSE FEATURE (TTC)

The Timer to Close feature requires The Protector System

TM

(IR Beams) to be installed.

Operation:

This feature allows the door to automatically close from a fully

open position after a specified time. The delay can be set from

10 to 180 seconds in 10 second increments, by using the

opener control buttons.
If the door encounters an obstruction while closing, the door

will stop and return to the UP position. The Courtesy lamp will

then flash 10 times.

To Activate TTC, or change a preset time:

1.Start with the door fully

CLOSED.

2.Enter into TTC Activation mode by pressing both

PROG

and

DOWN

buttons together for 3 seconds (figure 1).

Release when the courtesy light flashes twice.

3.Press the

UP

button once for each 10 second increment

required of TTC (figure 2. eg. twice for 20 seconds). Press

the

DOWN

arrow to reduce, if needed.

4.Press and release the

PROG

button to save this time

(figure 3), Courtesy light will flash once. TTC is now

activated.

TEST:

Operate the door to the UP position. Keep clear of the

IR Beams and check the door closes after the preset time.

To Deactivate TTC:

1.Enter into TTC Activation mode by pressing both

PROG

and

DOWN

buttons together for 3 seconds (figure 1).

Release when the courtesy light flashes twice.

2.Press and release the

PROG

button to save (figure 3),

courtesy light will flash once. TTC is now deactivated.

Indicator LED

Indicator LED

figure 1

figure 2

Indicator LED

figure 3

or

figure 4

Door may operate unexpectedly, therefore do not

allow anything to stay in the path of the door.

14

24

Содержание PowerLift Plus CS100EVO

Страница 1: ...e reference CS100EVO Sectional Garage Door Opener Installation and Operating Instructions This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGH...

Страница 2: ...pace exposed to weather To avoid damage to very light doors such as fibreglass aluminium or steel doors an appropriate reinforcement should be added To do so contact the door manufacturer SAVE THESE I...

Страница 3: ...irely by its springs Raise and lower the door to see if there is any binding or sticking 20 kgf is the absolute maximum allowable force to raise or lower the door in any position If your door binds st...

Страница 4: ...w w w chamberlaindiy com au ww w chamberlaindiy co nz CARTON INVENTORY 1 Opener 2 Hand held transmitter x 2 3 Remote control visor mount 4 Curved door arm 5 Hanging bracket 2 6 Rail bracket 7 Header b...

Страница 5: ...djustment procedures in this manual you may find it helpful to refer back to this illustration of a completed installation COMPLETED INSTALLATION 10 4x 9 8x 8 4x 7 1x 6 1x 1 1x 2 1x 3 4x 4 4x 5 4x HAR...

Страница 6: ...and learn the forces manually 7 Indicator LED used to indicate various programming modes No Function Colour Polarity Comment 0 E Serial port Green ve Serial Communication Input 1 Push button Red ve D...

Страница 7: ...s item 9 in Hardware Provided Section 5 This completes the assembly of the door opener to the rail FASTEN RAIL TO OPENER 9 10 The segmented rail is largely preassembled and consists of 4 parts The car...

Страница 8: ...created in the previous section for proper placement of header bracket A Wall mount centre the header bracket 1 on the vertical centre line 2 with the bottom edge of the header bracket on the horizon...

Страница 9: ...etween door and rail 1 Raise the opener onto support 2 Open the door completely place a 50 mm spacer between the door and the rail as shown 3 The final positioning of the rail should be relatively par...

Страница 10: ...of holes available Note Use 18mm Screws item 9 in Hardware Provided Section 5 FASTEN DOOR BRACKET 15 16 The opener must be securely fastened to a sound structural support above the opener 1 Postion th...

Страница 11: ...y if required see figure 3 Unscrew the front two screws in the trolley assembly Remove the straight arm pivot and reassemble with the curved arm bracket ATTACH DOOR ARM TO TROLLEY OPERATING THE MANUAL...

Страница 12: ...row Button will begin to flash figure 4 4 Press and hold the DOWN Arrow Button until the door is in the desired DOWN position figure 5 NOTE The UP and DOWN Arrow Buttons can be used to move the door u...

Страница 13: ...repeat Program the Limits and Force then repeat safety reverse test 1 40mm The safety reverse system test is important Garage door must reverse on contact with a 40 mm obstacle laid flat on the floor...

Страница 14: ...using to maintain the correct IP rating and continued operation One sensor is a Sending Eye the other is a Receiving Eye Try to avoid positioning these in direct sunlight as this may interfere with th...

Страница 15: ...he courtesy light flashes twice 3 Press the UP button once for each 10 second increment required of TTC figure 2 eg twice for 20 seconds Press the DOWN arrow to reduce if needed 4 Press and release th...

Страница 16: ...he Courtesy light will flash twice indicating the deactivation has occurred NOTE Erasing all remote control codes as in the Wireless programming section will also delete this feature PARTIAL OPENING F...

Страница 17: ...e code If you release the remote control push button before the opener light flashes the opener has not learned the code Now the opener will operate the door when the remote control push button is pre...

Страница 18: ...nce a Month Manually operate door If it is unbalanced or binding call a qualified door technician Check to be sure door opens closes fully Adjust limits and or force if necessary Repeat the safety rev...

Страница 19: ...E1702C 774AML E940C 4 5 1 2 E950C 1 Model E950C 2 Channel remote control 2 Model E940C 1 Channel visor remote control 3 Model 774AML The Protector SystemTM 4 Model E1702C Quick release lock 5 Model E8...

Страница 20: ...cturing process and may have dislodged 12 The Up and DOWN arrows on the control panel are flashing in sequence Check the diagnostic code on next page 1 Opener doesn t operate from either door control...

Страница 21: ...nsors to ensure both LEDs are steady and not flickering Make sure nothing is hanging or mounted on the door that would interrupt the sensors path while closing No RPM pulses have been detected Check t...

Страница 22: ...ivalent Door Linkage Adjustable door arm Pull cord trolley release Safety Personal Push button stop in UP and DOWN direction Automatic safety reverse in both UP and DOWN direction Electronic Automatic...

Страница 23: ...and or return the Unit to you This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding specifications installation...

Страница 24: ...mberlain Group Inc TM Trademark of The Chamberlain Group Inc Registered Trademark of The Chamberlain Group Inc Warranty Registration Register your warranty at chamberlaindiy com au warranty or chamber...

Отзывы: