nstallation TPD10-05

 

Содержание TPD10-05

Страница 1: ...Mechanical electrical installation TPD10 05...

Страница 2: ...xercise caution and do not wear rings watches or loose clothing Make sure that people who install maintain or operate the gate drive and or the control board are qualified and follow these instruction...

Страница 3: ...d Operation is important Influence of temperature Low outdoor temperatures can impede or even prevent starting torque ground deformation etc High outdoor temperatures can lead to premature initiation...

Страница 4: ...r and tear on the motor gate and fittings Operating a gate without fixed limit stops results in poor performance It is often dangerous leads to premature wear and voids your warranty 900 900 Max gate...

Страница 5: ...adjusted INSTALLATION Instead of steel or plastic expanding anchors which are less suitable use adhesive composite anchors where a set screw is glued into brickwork free of stress With pillars made o...

Страница 6: ...cure pin with R clip Turn release lever towards pillar Done The gate should now be slightly open This will be corrected during the learn cycle later on Note The hinge on the gate must be lubricated sl...

Страница 7: ...pecifies that the closing forces at the gate edge must not exceed 400 N 40 kg for the last 500 mm before the door is CLOSED Above 500 mm the maximum force at the gate edge must not exceed 1400 N 140 k...

Страница 8: ...nto fastening clips C Fasten transformer onto baseplate using the large screw and large washer D Put the 4 large closure screws through cover of the box Fasten 2 of them left or right approx 2cm into...

Страница 9: ...erature 20 C 55 C Degree of protection IP54 WIRING OF CONTROL SUMMARY a start with still dead 230Volts supply cable on the left side of the box b Attach cable eye to ground wire Then connect ground wi...

Страница 10: ...cells 2 e l o p e v i t a g e n M O C STOP 8 2KOhms connector for emergency switch or safety edge with 8 2KOhms E lock symbol connection for E lock control board INPUT 24VAC 24V power input from trans...

Страница 11: ...xt to the transformer on to the baseplate using screws Open its casing and make all necessary electrical wiring Plug support board in to where the E lock symbol is depicted 30VDC MOTOR MASTER MOTOR SE...

Страница 12: ...y edge causes the wings to reverse for one second FREE Factory setting is for 8 2 KOhms In this case safety edge must be installed or a 8 2 KOhms resistor must be connected LINKED used for emergency s...

Страница 13: ...4 failed wait for the LEDs control board and remote control to go out Then start again with step 2 Up to 180 remote controls can be programmed likewise In case no remote control is to be be programmed...

Страница 14: ...housing must not touch the gate Stop opening several times and check If housing touches the gate dimensions A B must be checked and if necessary underlay the gate pillar with flat washers in order to...

Страница 15: ...or 2 starts closing automatically 7 Press P1 again SOFT STOP for wing motor 2 in CLOSE direction begins at this point 8 Press P1 again when CLOSE position is reached Now wing motor 1 starts automatica...

Страница 16: ...Gate is rough running B Check if gate can be easily moved C Gate stopped through windload C Do not operate gate by windstorm D Reprogram travel to achieve sufficient level of fo 7x blinking Photocell...

Страница 17: ...1 Programming remote control 2 Find and rectify fault s see description of LEDs 3 Check photocell connection programming 4 Check terminals and connections Control board does not work with transmitter...

Страница 18: ......

Страница 19: ......

Страница 20: ...Chamberlain GmbH 2016 114A4623D en Chamberlain GmbH Alfred Nobel Strasse 4 66793 Saarwellingen Germany www chamberlain eu diy chamberlain eu...