background image

Installation Step 6

Install the Door Control 

18

Opener Terminal Screws

Antenna

Right Panel of Opener

KG

KG

1

3

9

7

5

1

3

9

7

5

2

3

1

Push Bar

Light Button

Lock

 Button

LOCK

LIGHT

1
RED

2
WHITE

Door

 Control

Terminal

Screws

2-Conductor

Bell Wire

Locate the door control within sight of the door at a
minimum height of 5 feet where small children
cannot reach, and away from all moving parts of the
door and door hardware.
The door control is typically attached directly to the
wall. If installing into drywall, drill 5/32" holes and
use the anchors provided. For pre-wired installations
(as in new home construction), it may be mounted to
a standard single gang box. See illustrations.
1. Strip 1/4" of insulation from one end of the bell

wire. Connect wire to the two screw terminals on
the back of the door control: white wire to 2 and
white/red wire to 1.

2. Remove the push bar cover by gently prying off

the top edge with a coin or screwdriver. Fasten
with 6ABx1-1/4" self-tapping screws (standard
installation) or 6-32x1" machine screws (pre-wired
installation) as follows:

• Install bottom screw, allowing 1/8" to protrude

from the wall. 

• Position bottom of door control on screw head

and adjust for snug fit. 

• Install top screw with care to avoid cracking

plastic housing. 

Do not overtighten.

3.

(For standard wall mount only)
Run the bell wire up wall and across ceiling to
opener. Use insulated staples to secure wire in
several places. Be careful not to pierce wire with a
staple, creating a short.

4. Connect the bell wire to the terminal screws on

the opener panel: white to 2; white/red to 1.

5. After testing, replace the cover by inserting top

tabs and snapping into place.

Note: After installation, the green indicator light
behind the push bar cover will indicate proper
connection. 
The automatic light feature will become functional
1-1/2 minutes after power is restored.

This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.

Do not connect to live electrical wiring. Connect
only to 24 Volt low voltage wires. Connection to
live wires or higher voltage may cause serious
injury from shock, burn or electrocution. 
Children operating or playing with a garage
door opener can injure themselves or others.
The garage door could close and cause
serious injury or death. Do not allow children
to operate the push buttons or remote controls.
A moving garage door could injure someone
under it. Activate the opener only when the
door is properly adjusted, you can see it clearly,
and there are no obstructions to door travel.

6ABx1-1/4" Screw

Door Control

Insulated 

Staples

Dry Wall 

Anchors

Screw 6-32x1" 

Hardware Shown

Actual Size

WARNING

LOCK

LIGHT

To Replace

Insert Top
Tabs First

STANDARD WALL MOUNT

Detector

Switch

Push Bar Cover

ON
OFF

24 Volt

2-Conductor

Bell Wire

PRE-WIRED INSTALLATION

LOCK

LIGHT

To Replace

Insert Top
Tabs First

Detector

 Switch

Push Bar Cover

ON
OFF

Outside Keylock Accessory Connections

To opener terminal screws: white to 2; white/red to 1

Содержание Security+ 9500-3K

Страница 1: ...r WILL NOT CLOSE unless the Protector System is connected and properly aligned Periodic checks of the opener are required to ensure safe operation The model number label is located under the light len...

Страница 2: ...trolley sectional door 26 Connect door arm to trolley one piece door 27 Adjustment section pages 28 30 Travel limit adjustments 28 Force adjustments 29 Test the Protector System 30 Test the safety rev...

Страница 3: ...Do not try to loosen move or adjust them yourself Ropes left on a garage door could cause someone to become entangled and killed Remove all ropes connected to the door before installing and operating...

Страница 4: ...pon garage construction extension brackets see Accessories or wood blocks may be needed to fasten sensors to mounting locations Step 10 page 22 Floor mounting of the safety reversing sensor will requi...

Страница 5: ...reversing sensor page 21 Depending on garage construction extension brackets see Accessories or wood blocks may be needed to fasten sensors to mounting locations Step 10 page 22 Floor mounting of the...

Страница 6: ...racket SECURITY Multi Function Remote Control Transmitter 2 LOCK LIGHT SECURITY Mini Remote Control Safety Labels and Literature 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Con...

Страница 7: ...16 18x2 1 2 2 Carriage Bolt 1 4 20x1 2 12 Master Link 2 Ring Fastener 3 Trolley Threaded Shaft 1 Lock Washer 5 16 6 Lag Screw 5 16 9x1 5 8 2 SAFETY REVERSING SENSOR Wing Nut 2 Insulated Staples 20 RA...

Страница 8: ...ucted to do so Assembly Section Pages 8 11 When tightening the screws be sure to keep bracket parallel to the rail Otherwise the rail may bow when the opener is operated Right Wrong Align the 4 T rail...

Страница 9: ...5 16 18x1 2 washered screws mounted in the top of the opener Align the holes in the back section of the T rail with the holes in the opener Fasten the rail with the 2 washered screws previously remove...

Страница 10: ...eth must engage the belt Figure 2 Use the second master link to connect the belt to the flat end of the trolley threaded shaft Figure 1 Check to make sure the belt is not twisted Remove the screwdrive...

Страница 11: ...structed to do so 6 Locate the Door Control within sight of the door at a minimum height of 5 feet where small children cannot reach and away from all moving parts of the door 7 Install the User Safet...

Страница 12: ...rance is minimal It may be mounted on the wall upside down if necessary to gain approximately 1 2 If you need to install the header bracket on a 2x4 on wall or ceiling use lag screws not supplied to s...

Страница 13: ...acket height on header wall 12 Measure UP from top of CLOSED door Proceed to Step 2 page 14 13 Header Wall Highest Point of Travel Door Distance Jamb Hardware Door Highest Point of Travel Header Wall...

Страница 14: ...use the holes designated for ceiling mount Drill 3 16 pilot holes and fasten the bracket securely to a structural support with the hardware provided Fasten the Header Bracket to the Ceiling Installat...

Страница 15: ...e garage floor below the header bracket Use packing material as a protective base If the door spring is in the way you ll need help Have someone hold the opener securely on a temporary support to allo...

Страница 16: ...T rail If the top panel hits the trolley when you raise the door pull down on the trolley release arm to disconnect the inner and outer sections The trolley can remain disconnected until Step 12 is c...

Страница 17: ...ke sure the T rail is centered over the door or in line with the header bracket if the bracket is not centered above the door Remove the 2x4 Operate the door manually If the door hits the rail raise t...

Страница 18: ...ort 4 Connect the bell wire to the terminal screws on the opener panel white to 2 white red to 1 5 After testing replace the cover by inserting top tabs and snapping into place Note After installation...

Страница 19: ...ors are heavy If the door is open when the handle is pulled the door could close inadvertently if it is not properly balanced Serious injury may result to persons under the door Make sure the doorway...

Страница 20: ...Black Wire To make a permanent connection through the 7 8 diameter hole in the top of the opener according to local code Remove the opener cover screws and set the cover aside Remove the attached 3 p...

Страница 21: ...cator light transmits an invisible light beam to the receiving eye with a green indicator light If an obstruction breaks the light beam while the door is closing the door will stop and reverse to full...

Страница 22: ...curved arms facing the door Snap into place against the side of the track It should lie flush with the lip hugging the back edge of the track as shown in Figure 2 If your door track will not support t...

Страница 23: ...rrect The sending eye orange indicator light will glow regardless of alignment or obstruction If the green indicator light in the receiving eye is off dim or flickering and the invisible light beam pa...

Страница 24: ...the bracket Position the bracket on the face of the door within the following limits A The top edge of the bracket 2 4 below the top edge of the door B The top edge of the bracket directly below any s...

Страница 25: ...edure Center the bracket on the top of the door in line with the header bracket as shown Mark holes Drill 5 16 pilot holes and fasten the door bracket with hardware provided If the door has no exposed...

Страница 26: ...n sections Select holes as far apart as possible to increase door arm rigidity Figure 3 If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 from the solid end Re...

Страница 27: ...ion parallel to the floor and lift the door arm to the trolley The arm should touch the trolley just in back of the door arm connector hole Refer to the fully open trolley door arm positions in the il...

Страница 28: ...se One turn equals 2 of travel NOTE To prevent the trolley from hitting the cover protection bolt keep a minimum distance of 2 4 between the trolley and the bolt If door does not open at least 5 feet...

Страница 29: ...nterclockwise Make 10 degree turn adjustments until the door stops easily After each adjustment run the opener through a complete travel cycle If the door doesn t open at least 5 feet Increase UP Open...

Страница 30: ...ed 30 Adjustment Step 3 Test the Protector System Press the remote control push button to open the door Place the opener carton in the path of the door Press the remote control push button to close th...

Страница 31: ...eded and the safety reversal system must be checked Failure to properly adjust the opener may result in severe injury or death 5 If possible use the manual release only when the door is in a closed po...

Страница 32: ...disable the motion sensor See Automatic Light Feature following The 4 1 2 minute interval can be changed to 1 1 2 2 1 2 or 3 1 2 minutes as follows Press and hold the Lock button until the light blink...

Страница 33: ...r to match any additional remotes you may purchase See Accessories on page 38 To Add A Remote Control Using the Multi Function door control 1 With the door closed press and hold a remote control push...

Страница 34: ...ng procedure with all remote controls The remote control has short range The garage door opens and closes by itself 1 Be sure that all remote control push buttons are off 2 Remove the bell wire from t...

Страница 35: ...page 32 2 The Outside Quick Release accessory for use on garages with no service door disconnects the trolley from outside the garage in case of power failure 35 The door reverses for no apparent rea...

Страница 36: ...ware illustrated on page 7 KEY PART NO NO DESCRIPTION 1 41C0472 5 Motion detecting control panel 2 41A5056 19 Multi function remote control housing screw only no circuit board 3 10A20 3V2032 Lithium B...

Страница 37: ...harness assembly with plug 6 41A5021 5E Receiver logic board assembly Complete with Logic board 7 41A3673 1 End panel w all labels 8 175B88M Light socket 9 108D34 Lens KEY PART NO NO DESCRIPTION 10 3...

Страница 38: ...opener light will blink three times Release the button 2 Press the temporary 4 digit password you have chosen then press Enter The opener light will blink four times 3 To set the number of hours this...

Страница 39: ...8 31 Manual Release Rope and Handle Lockout feature 32 Manual disconnect 32 Safety warnings 11 19 31 32 Opener Terminals Door control connections 18 Safety reversing sensor connections 23 Outside Keyl...

Страница 40: ...or reconditioned unit of the same or equal design Obtaining Service It s as easy as calling our toll free hotline at 1 888 528 6305 We will then 1 attempt to solve the problem with you over the phone...