INSTALLATION STEP 7

Install the Door Control

Locate door control within sight of door at a minimum 
height of 5 feet (1.5 m) where small children cannot 
reach, and away from moving parts of door and door 
hardware. The installation surface must be smooth and 
fl at. If installing into drywall (Figure 1), drill 5/32" holes 
and use anchors provided. For pre-wired installations (as 
in new home construction), it may be mounted to a single 
gang box (Figure 2). 

NOTE: 

After installation, a green or 

amber indicator light behind the cover will indicate proper 
connection. If not lit, the Lock and Light features will not 
function (reverse wires to correct).

1.   Strip 7/16" (11 mm) of insulation from one end of bell 

wire and connect to the two screw terminals on back of 
door control by color: white wire to WHT and white/red 
wire to the RED (Figure 3).

2.   Remove cover by gently prying on a side corner near the 

top of the cover with a small fl at head screwdriver 
(Figure 4). Fasten with 6ABx1-1/4" self-tapping screws 
(drywall installation) or 6-32x1" machine screws (into 
gang box) as follows:

 

•   Drill and install bottom screw, allowing 1/8" (3 mm) to 

protrude above wall surface.

 

•   Position bottom of door control on screw head and 

slide down to secure. Adjust screw for snug fi t.

 

•   Install top screw with care to avoid cracking plastic 

housing. 

Do not overtighten.

 

•   Insert bottom tabs and snap on cover. 

 

 NOTE: 

The push bar may stick if the door control is not 

mounted on a smooth surface. If a click is not heard when 
pressing the push bar, loosen the two mounting screws 
or relocate the door control to a smoother surface.

3.  

(Standard installation only)

 Run bell wire up wall and 

across ceiling to motor unit. Use insulated staples to 
secure wire in several places. Do not pierce wire with a 
staple, creating a short or open circuit. If your access 
door is near the garage door, you may run this wire with 
the Safety Reversing Sensor wires along the top of the 
rail. See page 17.

4.   Insert all wires through the opening on top of motor unit 

above the terminal block on the back panel (Figure 4).

5.   Strip 7/16" (11 mm) of insulation from each set of bell 

wires. Connect bell wires to the quick-connect terminals 
as follows: white to white and white/red to red; white to 
white and white/black to grey (Figure 5).

 

 NOTE: 

When connecting multiple door controls to the 

opener, twist same color wires together. Insert wires into 
quick-connect holes: white to white and red/white to red.

6.   Use tacks or staples to permanently attach entrapment 

warning label to wall near door control, and manual 
release/safety reverse test label in a prominent location 
on inside of garage door.

NOTE: 

DO NOT connect the power and operate the opener at 

this time. The trolley will travel to the full open position but 
will not return to the close position until the sensor beam is 
connected and properly aligned.

To prevent possible SERIOUS INJURY or DEATH from 
electrocution:
•   Be sure power is NOT connected BEFORE installing 

door control.

•   Connect ONLY to 24 VOLT low voltage wires. 
To prevent possible SERIOUS INJURY or DEATH from a 
closing garage door:
•   Install door control within sight of garage door, out 

of reach of children at a minimum height of 5 feet 
(1.52 m), and away from all moving parts of door.

•   NEVER permit children to operate or play with door 

control push buttons or remote control transmitters.

•   Activate door ONLY when it can be seen clearly, is 

properly adjusted, and there are no obstructions to 
door travel.

•   ALWAYS keep garage door in sight until completely 

closed. NEVER permit anyone to cross path of 
closing garage door.

HARDWARE SHOWN ACTUAL SIZE

Drywall Anchors

Insulated
Staples

Screw 6ABx1-1/4"
Control Panel (std installation)

Screw 6-32x1"
Control Panel (pre-wired)

Figure 2

Figure 1

To Replace Insert 
Bottom Tabs First

To Replace
Insert Bottom
Tabs First

24 Volt
Bell Wire

STANDARD 
INSTALLATION

PRE-WIRED 
INSTALLATION

KG

1

3

9

7

5

KG

1

3

9

7

5

To release or insert wire, push 
in tab with screwdriver tip

Red

7/16" 
(11 mm)

White Grey

Door Control Connections

Figure 4

Figure 3

MULTI-FUNCTION
WALL CONTROL PANEL

 Top Mounting Hole

Terminal 
Screws

Bell Wire

Bottom
Mounting Hole

Strip wire 7/16" (11 mm)

Safety Sensor Connections

Содержание PD432DM 1/2 HP Owners

Страница 1: ...er s Manual Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless The Protector System is connect...

Страница 2: ...sten the rail to the motor unit and install the trolley 10 Attach the rail brackets 11 Installation 11 26 Installation safety instructions 11 Determine the header bracket location 12 Install the heade...

Страница 3: ...disable locks BEFORE installing and operating the opener ONLY operate garage door opener at 120V 60 Hz to avoid malfunction and damage Sectional Door One Piece Door Preparing your garage door Before y...

Страница 4: ...where it meets the oor Any gap between the oor and the bottom of the door must not exceed 1 4 6 mm Otherwise the safety reversal system may not work properly See Adjustment Step 3 Floor or door shoul...

Страница 5: ...r or the garage door MUST be repaired to eliminate the gap ONE PIECE DOOR WITHOUT TRACK ONE PIECE DOOR WITH TRACK Header Wall FINISHED CEILING Support bracket fastening hardware is required See page 1...

Страница 6: ...te Carton Inventory UP CE ILING MOUN T ONL Y LOCK LIGHT SECURITY 1 Button Remote Control 2 Multi Function Door Control Panel Remote Control Visor Clip Motor Unit with 2 Light Lenses Door Bracket Heade...

Страница 7: ...Pin 5 16 x1 1 Rope Screw 6ABx1 1 4 2 Screw 6 32x1 2 Hex Bolt 5 16 18x7 8 4 Lock Washer 5 16 6 Insulated Staples 30 Wing Nut 1 4 20 2 Ring Fastener 3 Nut 5 16 18 6 Handle Hardware Inventory Separate al...

Страница 8: ...rail has a black gear on one end The header rail has a black plastic rack inside the rail on the screw The remaining section is the center rail NOTE Use caution when handling the center rail section T...

Страница 9: ...ction Figure 3 6 Place the c clip onto the long journal shaft center rail to ensure that the sleeve does not slide Figure 4 7 Slide the center rail so that the center rail and rail brace holes are ali...

Страница 10: ...motor unit bracket until the coupling ts securely over the motor unit sprocket 4 Align the four bolt holes in the rail with those in the motor unit bracket Insert four 1 4 20x7 16 hex bolts Tighten se...

Страница 11: ...ORE installing opener 4 Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement 5 Install garage door opener 7 feet 2 13 m or more above oor 6 Mo...

Страница 12: ...r the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 13 for ceiling installation To prevent possib...

Страница 13: ...the vertical set of bracket holes do not use the holes designated for ceiling mount Drill 3 16 pilot holes and fasten the bracket securely to a structural support with the hardware provided HARDWARE...

Страница 14: ...e rail to clear the spring Position the header rail bracket against the header bracket Align the bracket holes and join with a clevis pin 5 16 x2 3 4 as shown Spacer can be installed on either side of...

Страница 15: ...designed to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such...

Страница 16: ...oor Attach brackets to wall with lag screws Not provided If using extension brackets or wood blocks adjust right and left assemblies to the same distance out from the mounting surface Make sure all d...

Страница 17: ...e rail at the door header see Figure 6 2 Run the wires through wire clip at the top of the rails NOTE If your access door is near the garage door you may choose to install the door control at this tim...

Страница 18: ...ction or panel hits the trolley when you raise the door pull down on the trolley release arm to disconnect inner and outer sections Slide the outer trolley toward the motor unit The trolley can remain...

Страница 19: ...ock washers and nuts 6 Check to make sure the rail is centered over the door or in line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually...

Страница 20: ...motor unit above the terminal block on the back panel Figure 4 5 Strip 7 16 11 mm of insulation from each set of bell wires Connect bell wires to the quick connect terminals as follows white to white...

Страница 21: ...lease arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the oor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Secure with an overh...

Страница 22: ...NT WIRING CONNECTION Green Ground Screw Ground Tab Ground Wire White Wire White Wire Black Wire Black Wire TROUBLESHOOTING THE SAFETY REVERSING SENSORS 1 If the sending eye indicator light does not gl...

Страница 23: ...r the vertical brace 2 pieces of angle iron are used to create a U shaped support The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit NOT...

Страница 24: ...of Door Optional Placement Optional Placement Nut 5 16 18 Carriage Bolt 5 16 x2 Not Provided Lock Washer 5 16 ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on...

Страница 25: ...2 Bring arm sections together Find two pairs of holes that line up and join sections Select holes as far apart as possible to increase door arm rigidity Figure 3 Hole alignment alternative If holes in...

Страница 26: ...trolley will travel to the fully closed position Figure 5 Figure 6 Manually close the door and lift the door arm to the trolley The arm should touch the trolley just ahead of the door arm connector ho...

Страница 27: ...ment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t close completely try l...

Страница 28: ...by turning the control clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the...

Страница 29: ...nt of the opener ADJUSTMENT STEP 4 Test The Protector System Press the remote control push button to open the door Place the opener carton in the path of the door Press the remote control push button...

Страница 30: ...will operate with up to eight Security remote controls and one Security Keyless Entry System If you purchase a new remote or if you wish to deactivate any remote follow the instructions in the Progra...

Страница 31: ...or 2 seconds The push button light will stop ashing The Lock feature will also turn off whenever the learn button on the motor unit panel is activated Lock Button Light Button Push Button To Open the...

Страница 32: ...TERY To prevent possible SERIOUS INJURY or DEATH NEVER allow small children near batteries If battery is swallowed immediately notify doctor To reduce risk of re explosion or chemical burn Replace ONL...

Страница 33: ...ill not activate your door check diagnostic LED for ashes on motor unit then refer to Diagnostic Chart on the following page 3 My door reverses for no apparent reason Repeat safety reverse test after...

Страница 34: ...wires at door control touch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and...

Страница 35: ...two clicks will be heard 1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand h...

Страница 36: ...l entry PIN not the last temporary PIN then press and hold the button The opener light will blink three times Release the button 2 Press the temporary 4 digit PIN you have chosen then press ENTER The...

Страница 37: ...ontrol 3 10A20 3V 2032 Lithium battery 4 29B137 Visor clip 5 41A2828 Emergency release rope handle assy 6 41B4494 1 2 Conductor bell wire white white red 7 41A4353 Header bracket w clevis pin fastener...

Страница 38: ...ck w screws 5 41D4671 Limit switch assembly 6 41A6241 Motor drive assembly 6a 20B21 1 Drive belt 7 41C4672 Screw drive RPM kit KEY PART NO NO DESCRIPTION 8 41A4837 1 Worm gear and retainer 9 41A6635 L...

Страница 39: ...ur home 956D 3 Button Mini Remote Control with SECURITY With key ring and fastening strip 1702LMC Outside Quick Release Required for a garage with NO access door CLLAD Remote Light Control Enables hom...

Страница 40: ...are con rmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or repla...

Отзывы: