Chamberlain Merlin Professional MR800 Скачать руководство пользователя страница 2

1

The Protector System must be used for all
installations where the closing force as measured
on the bottom of the door is over 400N (40kgf).
Excessive force will interfere with the proper operation

of the Safety Reverse System or damage the garage
door.

After installation, ensure that the parts of the door
do not extend over public footpaths or roads.

Disengage all existing garage door locks to avoid
damage to garage door.
Install the wireless wall control (or any additional wall

control)

in a location where the garage door is

visible, at a height of at least 1.5m and out of the
reach of children. The appliance is not intended for
use by young children or infirm persons without
supervision. 
Serious personal injury from a closing
garage door may result from misuse of the opener.

Permanently fasten the Warning Label adjacent to the
wall control as a reminder of safe operating procedures.

Activate opener only when the door is in full view,
free of obstructions and the opener is properly
adjusted. No one should enter or leave the garage
while the door is in motion.

Do not allow children to play near the door.

Disconnect electric power to the garage door
opener before making repairs or removing covers.

SAVE THESE INSTRUCTIONS

WARNING: Failure to comply with the following instructions may result in serious personal injury or property damage.

• Read these instructions carefully and follow ALL instructions carefully

• The garage door opener is designed and tested to offer reasonable safe service provided it is installed and

operated in strict accordance with the instructions in this manual.

These safety alert symbols mean

WARNING – a personal safety or property damage instruction.

Read these instructions carefully.

Warning: If your garage has no service entrance door, a 1702AML outside quick release must be installed. This accessory allows
manual operation of the garage door from outside in case of power failure.

Keep garage door balanced. Do not let the garage
door opener compensate for a binding or sticking
garage door. Sticking or binding doors must be
repaired. Garage doors, door springs, brackets and
their hardware are under extreme tension and can
cause serious personal injury.

Do not wear rings, watches or loose clothing while
installing or servicing a garage door opener.

To avoid serious personal injury from entanglement,
remove all ropes, chains and locks connected to
the garage door 
before installing the door opener.

Installation and wiring must be in compliance with your
local building and electrical codes.

The safety reverse system test is very important.
Your garage door

MUST reverse on contact with a

40mm obstacle placed on the floor. Failure to properly
adjust the opener may result in serious personal injury
from a closing garage door.

Repeat the test once a

month and make any necessary adjustments.
This opener should not be installed in a damp or

wet space.

Take care when operating the manual release as an
open door may fall rapidly due to weak or broken
springs, or being out of balance.

The drive must not be used on a wicket door (door
within a door)

Start by Reading These Important Safety Instructions

Tools Required

2

1. Ladder (or similar device to safely support door weight)
2. Adjustable wrench for U-bolts already installed on the

door

3. 8mm socket, 10mm socket and 13mm extended socket

and socket wrench

4. 12inch socket extension (for minimum sideroom

installations)

5. Drill and 5.5mm drill bit
6. Philip's head screw driver
7. Marker Pen

1

2

3

13mm, 10mm, 8mm

4

5.5mm

5

6

7

Carton Inventory

1

!

2

3

4

5

6

7

8

Installation and operating instructions
for Merlin garage door opener
Model MR800

1

9

10

1. Instruction manual (this document)

2. Stop bracket collar
3. Clamp bracket
4. Release handle and cord
5. C945 remote control (2)
6. CM128 wireless wall control
7. Extension poles (2)
8. Weight bar
9. Bracket plate

10. Hardware bag

Содержание Merlin Professional MR800

Страница 1: ...professional N2966 professional Installation and operating instructions for Merlin garage door opener Model MR800 www chamberlainanz com...

Страница 2: ...is accessory allows manual operation of the garage door from outside in case of power failure Keep garage door balanced Do not let the garage door opener compensate for a binding or sticking garage do...

Страница 3: ...and lower the door to discover if there are any sticking or binding points If your door spring does not hold the door in place or the door binds or sticks call a qualified door technician before auto...

Страница 4: ...ved manually NOTE To re engage the opener pull the release cord across and up For right hand side installations the wire jumper should be in place factory installed Set Opener Position Left or Right h...

Страница 5: ...move any ropes used Plug opener into nearby power point and switch on power point opener lights should now turn on FOR LEFT HAND INSTALLATIONS REFER SECTION 5 page 3 Ensure that the opener position ju...

Страница 6: ...re with an overhand knot at least 25mm from the end of the rope to prevent slipping Thread the other end of the rope through the loop of the manual release cable Adjust rope length so the handle is no...

Страница 7: ...he indicator light 2 will stop flashing when the limits have been learned NOTE If the door presses excessively on the floor or reverses before it reaches the floor use the Manual Limit setting option...

Страница 8: ...rage door must reverse on contact with a 40mm obstacle laid flat on the floor Failure to properly adjust the opener may result in serious personal injury from a closing garage door Operate the door in...

Страница 9: ...he white quick connect terminal The Protector System Safety Beams Connect both white wires to the white quick connect terminal and both white black wires to the grey quick connect terminal Flashing li...

Страница 10: ...nd force setting in section 11 12 pages 6 7 Repeat safety reverse test after adjustments 9 The opener strains to operate door The door may be out of balance or the springs may be broken Close the door...

Страница 11: ...llow a 15 minute cooling period after 4 minutes of continuous operation of the opener Opening the Door Manually Door should be fully closed if possible Weak or broken springs could allow an open door...

Страница 12: ...r Operator Unit that it is free from defects in material and or workmanship for a period of 2 YEARS from the date of first purchase from the Seller Please retain your proof of purchase in the unlikely...

Отзывы: