background image

4

Installation steps 

6

FOR RIGHT HAND INSTALLATIONS (REFER SECTION 5, page 3)

1. Ensure that the opener position jumper (wire connector) is in place (refer 

section 5, page 3).

2. Place the opener in manual release mode (refer section 5, page 3).

3. Open the roller door fully. For safety, tie a rope around the door.

4. 

Ensure that the U-bolt on the left hand side of the door is 

secure.

5. Mark the position of the door shaft on the right hand door bracket.

6. Carefully remove the U-bolt on the right hand side, checking that 

the spring tension inside the roller door is not being released.

7. You will need assistance for the following steps. Slide or lift the 

door shaft clear of the door bracket supporting the door weight

with a ladder or similar device. Then slip the opener over the shaft.

8. The forks should engage either side of the support spoke.

9. 

Typical installation:

Place the door shaft back onto the door bracket

in the position that it was originally. Clamp the opener to the door 

shaft with the supplied bracket plate, 8mm bolts and nuts. 

Tighten sufficiently to fasten the opener firmly to the shaft i.e. 25Nm-

28Nm. Replace U-bolt and secure firmly.

Minimum side room installation:

Place the opener and door shaft 

onto the door bracket in the position that the door shaft was originally. 

Clamp the opener to the door shaft though the door bracket with the 

supplied bracket plate, 8mm bolts and nuts.  Tighten sufficiently to fasten 

the opener firmly to the shaft i.e. 25Nm-28Nm.

10. Remove rope if used.

11. Plug opener into nearby power point and switch on power point, 

opener lights should now turn on.

FOR LEFT HAND SIDE INSTALLATIONS

1. Ensure that the opener position jumper (wire connector) has been 

removed (refer section 5, page 3).

2. Place the opener in manual release mode (refer section 5, page 3).

3. Open the roller door fully. For safety, tie a rope around the door.

4.

Ensure that the U-bolt on the right hand side of the door is

secure.

5. Mark the position of the door shaft on the left hand wall bracket

6. Carefully remove the U-bolt on the left hand side, checking that  

the spring tension inside the roller door is not being released.

7. You will need assistance for the following steps. Slide or lift the 

door shaft clear of the door bracket supporting the door weight 

with a ladder or similar device. Then slip the opener over the shaft.

8. The forks should engage either side of the support spoke.

9. 

Typical installation:

Place the door shaft back onto the door 

bracket in the position that it was originally. Clamp the opener to 

the door shaft with the supplied bracket plate, 8mm bolts and nuts.

Tighten sufficiently to fasten the opener firmly to the shaft i.e. 25Nm-

28Nm.Replace U-bolt and secure firmly.

Minimum side room installation:

Place the opener and door shaft

onto the door bracket in the position that the door shaft was 

originally. Clamp the opener to the door shaft though the door 

bracket with the supplied bracket plate, 8mm bolts and nuts. Tighten 

sufficiently to fasten the opener firmly to the shaft i.e. 25Nm-28Nm.  

12. Remove rope if used.

13. Plug opener into nearby power point and switch on power point, 

opener lights should now turn on.

Содержание LiftMaster Professional RDO800 Series

Страница 1: ...function Electronic limit switch programming Automatic force adjustment Safety system constantly monitors force door reverses immediately if obstructed Meets all current safety standards High security rolling code eliminates code scanning Light goes on automatically and switches off after 2 1 2 minutes Battery backup Slim design to save side room ...

Страница 2: ... 760E Outside keylock 1702E Outside quick release 770E Protector system FLA230 Flashing light kit 475E Battery backup system 128LM 2 function wireless wall control Ensure that there is at least 45mm from the edge of the curtain to the edge of the bracket If the roller door drums are on the edge of the curtain or are of small diameter additional clearance maybe required If the drums are more than 6...

Страница 3: ...lation and operating instructions for rolling door opener Model RDO800 series Chamberlain GmbH Alfred Nobel Strasse 4 66793 Saarwellingen Germany TEL 49 0 6838 907 250 FAX 49 0 6838 907 179 www liftmaster com ...

Страница 4: ...f the garage door from outside in case of power failure Keep garage door balanced Do not let the garage door opener compensate for a binding or sticking garage door Sticking or binding doors must be repaired Garage doors door springs brackets and their hardware are under extreme tension and can cause serious personal injury Do not wear rings watches or loose clothing while installing or servicing ...

Страница 5: ...ceeds 400N 40kgf Door shaft diameter must not exceed 35mm Prepare Door 4 Disable locks and remove any ropes connected to garage door Complete the following test to ensure your garage door is balanced and is not sticking or binding 1 Lift the door about halfway as shown Release the door If balanced it should stay in place supported entirely by its springs 2 Raise and lower the door to see if there ...

Страница 6: ...anually NOTE To re engage the opener pull the release cord across and up For right hand side installations the wire jumper should be in place factory installed Set Opener Position Left or Right hand Engaged Operation Mode Disengaged Manual Release Mode Attaching the Extension Poles if required 1 Insert the extension poles into the gear 2 Align the extension pole holes with the gear holes 3 Using t...

Страница 7: ...0 Remove rope if used 11 Plug opener into nearby power point and switch on power point opener lights should now turn on FOR LEFT HAND SIDE INSTALLATIONS 1 Ensure that the opener position jumper wire connector has been removed refer section 5 page 3 2 Place the opener in manual release mode refer section 5 page 3 3 Open the roller door fully For safety tie a rope around the door 4 Ensure that the U...

Страница 8: ...ure with an overhand knot at least 25mm from the end of the rope to prevent slipping Thread the other end of the rope through the link on the emergency release cable Adjust rope length so the handle is no higher than 1 8m above the floor Secure with an overhand knot If the door is greater than 2 5m in height the Release Cord Extension kit accessory is required NOTE If it is necessary to cut the ro...

Страница 9: ...which the door will stop when moving up or down Follow the steps below to set the limits Check that the opener is engaged To program the travel limits 1 Press and hold the black button 3 until the orange indicator light 2 starts flashing slowly and then release Opener lights will dim 2 Press the BLACK button to move the door UP or the PURPLE button to move the door DOWN until the door reaches the ...

Страница 10: ...tant The garage door must reverse on contact with a 40mm obstacle laid flat on the floor Failure to properly adjust the opener may result in serious personal injury from a closing garage door Operate the door in the down direction The door must reverse on the obstruction If the door stops on the obstruction remove obstruction and repeat limit and force setting sections 11 12 pages 6 7 Repeat test ...

Страница 11: ...k connect terminal and the white wire to the white quick connect terminal 2 The Protector System Safety Beams Connect both white wires to the white quick connect terminal and both white black wires to the grey quick connect terminal 3 Flashing light connection The flashing light can be installed anywhere 4 Battery Backup To access the battery backup connector remove the knockout to the right of th...

Страница 12: ...orce setting in section 11 12 pages 6 7 Repeat safety reverse test after adjustments 9 The opener strains to operate door The door may be out of balance or the springs may be broken Close the door and use the manual release to disconnect the door Open and close the door manually A properly balanced door will stay in any point of travel while being supported entirely by its springs If it does not d...

Страница 13: ...ng children Allow a 15 minute cooling period after 4 minutes of continuous operation of the opener Opening the Door Manually Door should be fully closed if possible Weak or broken springs could allow an open door to fall rapidly Property damage or serious personal injury could result The door can be opened manually by pulling the release cord down and across to engage the ball into the cup To reco...

Страница 14: ...warranty will be the purchaser s sole and exclusive remedy and neither Chamberlain nor its affiliates or distributors shall be liable for any incidental or consequential damages for any express or implied warranty relating to this product No representative or person is authorized to assume for Chamberlain any other liability in connection with the sale of this product EDR4 8004A 11 C 2007 Chamberl...

Отзывы: