background image

8

CARE OF YOUR OPENER

When properly installed, your opener will provide high performance with a minimum of maintenance. The opener does not
require additional lubrication. Limit and Force Settings: These settings must be checked and properly set when the opener is
installed. Weather conditions may cause some minor changes in the door operation, requiring some re-adjustments,
particularly during the first year of operation. Refer to limit and force setting in, sections  11 & 12, pages 6 & 7. Follow the
instructions carefully and repeat the safety reverse test after any adjustment. 

Remote Control: Additional remotes can be purchased at any time. Refer to Accessories. Any new remotes must be
programmed into the opener. Remote Control Battery: The lithium batteries should produce power for up to 5 years. If
transmission range lessens, replace the battery .

Special Features

1.Motion Detecting Control Panel

Connect white/red wire to the red quick connect
terminal and the white wire to the white quick connect 
terminal.

2.The Protector System™ (Safety Beams)

Connect both white wires to the white quick connect 
terminal and both white/black wires to the grey quick 
connect terminal.

3.Flashing light connection. 

The flashing light can be installed anywhere.

4.Battery Backup

To access the battery backup connector, remove
the knockout to the right of the start button.

5.Timer to close function

Is enabled by turning the dial to the required time.
The Protector System (Safety Beams) must be 
installed before using this function.

LOCK

LIGHT

1

2

3

4

5

0

50

180 sec.

15

Accessories

1. Model 128LM 2-Function Wireless Wall Control 

2. Model 94334E 4-Fuction Remote Control

3. Model 94330E Single-Function Remote Control

4. Model 94333E 3-Function Remote Control

5. Model 94335 3-Function Mini Remote Control

6. Model 9747E Keyless Entry System

7. Model 98LM Motion Detecting Control Panel

8. Model 760E Outside Keylock

9. Model 1702E Outside Quick Release

10. Model 770E The Protector System™

11. Model FLA230 Flashing Light Kit

12. Model 475 Battery Backup System

LOCK

LIGHT

1

2

3

4

5

6

7

8

9

10

11

12

16

Содержание LiftMaster Professional RDO800 Series

Страница 1: ...function Electronic limit switch programming Automatic force adjustment Safety system constantly monitors force door reverses immediately if obstructed Meets all current safety standards High security rolling code eliminates code scanning Light goes on automatically and switches off after 2 1 2 minutes Battery backup Slim design to save side room ...

Страница 2: ... 760E Outside keylock 1702E Outside quick release 770E Protector system FLA230 Flashing light kit 475E Battery backup system 128LM 2 function wireless wall control Ensure that there is at least 45mm from the edge of the curtain to the edge of the bracket If the roller door drums are on the edge of the curtain or are of small diameter additional clearance maybe required If the drums are more than 6...

Страница 3: ...lation and operating instructions for rolling door opener Model RDO800 series Chamberlain GmbH Alfred Nobel Strasse 4 66793 Saarwellingen Germany TEL 49 0 6838 907 250 FAX 49 0 6838 907 179 www liftmaster com ...

Страница 4: ...f the garage door from outside in case of power failure Keep garage door balanced Do not let the garage door opener compensate for a binding or sticking garage door Sticking or binding doors must be repaired Garage doors door springs brackets and their hardware are under extreme tension and can cause serious personal injury Do not wear rings watches or loose clothing while installing or servicing ...

Страница 5: ...ceeds 400N 40kgf Door shaft diameter must not exceed 35mm Prepare Door 4 Disable locks and remove any ropes connected to garage door Complete the following test to ensure your garage door is balanced and is not sticking or binding 1 Lift the door about halfway as shown Release the door If balanced it should stay in place supported entirely by its springs 2 Raise and lower the door to see if there ...

Страница 6: ...anually NOTE To re engage the opener pull the release cord across and up For right hand side installations the wire jumper should be in place factory installed Set Opener Position Left or Right hand Engaged Operation Mode Disengaged Manual Release Mode Attaching the Extension Poles if required 1 Insert the extension poles into the gear 2 Align the extension pole holes with the gear holes 3 Using t...

Страница 7: ...0 Remove rope if used 11 Plug opener into nearby power point and switch on power point opener lights should now turn on FOR LEFT HAND SIDE INSTALLATIONS 1 Ensure that the opener position jumper wire connector has been removed refer section 5 page 3 2 Place the opener in manual release mode refer section 5 page 3 3 Open the roller door fully For safety tie a rope around the door 4 Ensure that the U...

Страница 8: ...ure with an overhand knot at least 25mm from the end of the rope to prevent slipping Thread the other end of the rope through the link on the emergency release cable Adjust rope length so the handle is no higher than 1 8m above the floor Secure with an overhand knot If the door is greater than 2 5m in height the Release Cord Extension kit accessory is required NOTE If it is necessary to cut the ro...

Страница 9: ...which the door will stop when moving up or down Follow the steps below to set the limits Check that the opener is engaged To program the travel limits 1 Press and hold the black button 3 until the orange indicator light 2 starts flashing slowly and then release Opener lights will dim 2 Press the BLACK button to move the door UP or the PURPLE button to move the door DOWN until the door reaches the ...

Страница 10: ...tant The garage door must reverse on contact with a 40mm obstacle laid flat on the floor Failure to properly adjust the opener may result in serious personal injury from a closing garage door Operate the door in the down direction The door must reverse on the obstruction If the door stops on the obstruction remove obstruction and repeat limit and force setting sections 11 12 pages 6 7 Repeat test ...

Страница 11: ...k connect terminal and the white wire to the white quick connect terminal 2 The Protector System Safety Beams Connect both white wires to the white quick connect terminal and both white black wires to the grey quick connect terminal 3 Flashing light connection The flashing light can be installed anywhere 4 Battery Backup To access the battery backup connector remove the knockout to the right of th...

Страница 12: ...orce setting in section 11 12 pages 6 7 Repeat safety reverse test after adjustments 9 The opener strains to operate door The door may be out of balance or the springs may be broken Close the door and use the manual release to disconnect the door Open and close the door manually A properly balanced door will stay in any point of travel while being supported entirely by its springs If it does not d...

Страница 13: ...ng children Allow a 15 minute cooling period after 4 minutes of continuous operation of the opener Opening the Door Manually Door should be fully closed if possible Weak or broken springs could allow an open door to fall rapidly Property damage or serious personal injury could result The door can be opened manually by pulling the release cord down and across to engage the ball into the cup To reco...

Страница 14: ...warranty will be the purchaser s sole and exclusive remedy and neither Chamberlain nor its affiliates or distributors shall be liable for any incidental or consequential damages for any express or implied warranty relating to this product No representative or person is authorized to assume for Chamberlain any other liability in connection with the sale of this product EDR4 8004A 11 C 2007 Chamberl...

Отзывы: