background image

1-GB

Contents: General advice on
installation and use:
Contents list:  

page 1

Content of the carton:

figure

Before you begin:

page 2

Checklist:  

page 2

Gate types/installation height:

page 2, figure       

A-F

Gate configuration:

page 2, figure       

A-F

Gate stops:

page 2, figure       

A-F

Assembly measurements and opening
angle:  

pages 2-3, figures       

A-B

Post bracket/Gate fixing bracket:

pages 2-3, figures       

A-D

Release of drive arms:  

page 3, figure 

Installing the drive arms::

page 3, figure       

A-B

Wiring:

page 3, figure       

A-D

Maintenance work:  

page 3

Electrical Installation: + Electronic
Control:  

page 4, figure

Safety:

page 4

Flashing Lamp + Antenna:  

page 5, figure        

A-D +       A-B

IR Sensor: 

page 5, figure        

A-B

Key switch:

page 5, figure        

A-B

Initial setting of Remote control:

page 6, figure

Initial Operation:

page 6

Technical Data:  

page 6

Replacement Parts:  

figure

CONTENT OF THE CARTON 

(1)

Motor (1 or 2)

(2)

Electronic Control (1)

(3)

Postbracket (1 or 2)

(4)

Keys (2 or 4)

(5) 

Gate fixing bracket (1 or 2)

(6) 

Capacitor (1 or 2)

(7)

Manual (1)

(8) 

Clevis pin (2 or 4) and Rings (4 or 8)

(9)

3-Channel Remote Control Mini (1)

(10)

IR Sensor (1 pair)

(11)

Flashing lamp (1)

(12)

Antenna (1)

1

PLEASE START BY READING THESE IMPORTANT SAFETY RULES • SAVE THESE INSTRUCTIONS

This safety alert symbol means "Caution" - failure to comply with such an instruction involves risk of personal
injury or damage to property. Please read these warnings carefully.

This gate drive mechanism is designed and tested to offer appropriately safe service provided it is installed and
operated in strict accordance with the following safety rules.

Incorrect installation and/or failure to comply with the following instructions may result in serious personal injury
or property damage.

1

2

3

3

4

6

7

9

13

Installation and wiring must be in compliance
with your local building and electrical
installation codes. Power cables must only be
connected to a properly earthed supply.

Any entrapment possibility by the moving wing
between wing & walls must be secured with
safety edges or IR-sensors.

Disconnect electric power to the system before
making repairs or removing covers.

A disconnecting device must be provided in the
permanently-wired installation to guarantee  all-
pole disconnection by means of a switch (at least
3mm contact gap) or by a separate fuse.

When using tools and small parts to install or
carry out repair work on a gate exercise caution
and do not wear rings, watches or loose
clothing.

Make sure that people who install, maintain or
operate the gate drive follow these instructions.

Keep these instructions in a safe place so that you
can refer to them quickly when you need to.

Please remove any locks fitted to the gate in order
to prevent damage to the gate.

It is important to make sure that the gate always
runs smoothly. Gates which stick or jam must be
repaired immediately. 

Employ a qualified

technician to repair the gate, never attempt to
repair it yourself.

Keep additional accessories away from children. Do
not allow children to play with pushbuttons or remote
controls. A gate can cause serious injuries as it
closes.

After the installation a final test of the full
function of the system and the full function of
the safety devices must be done.

The full protection against potential squeeze or
entrappment must work direct when the drive
arms are installed.

This drive cannot be used with a gate
incorporating a wicket door unless the drive
cannot be operated with the wicket door open.

10

8

11

5

14

15

16

Содержание LiftMaster Professional LYN300KP

Страница 1: ...www liftmaster com info chamberlain com Instructions Wing Gate Operator LYN300KP KSP LYN400KP KSP TH PRC GB ROK VN...

Страница 2: ...y result in serious personal injury or property damage 1 2 3 3 4 6 7 9 13 Installation and wiring must be in compliance with your local building and electrical installation codes Power cables must onl...

Страница 3: ...s purpose than steel or plastic straddling plugs In the case of brickwork pillars bolt on a relatively large steel plate that covers several bricks and then weld the hinge plate to it An angle plate a...

Страница 4: ...ot eliminate the problems caused by a gate that does not work satisfactorily ELECTRONIC CONTROL The control board should be the last item to be connected i e mounting the motors laying the necessary c...

Страница 5: ...und knee height approx 35 cm above ground level IR Sensors comprise of a transmitter element and a receiver element which must be located opposite one another A screwdriver can be used to open the lig...

Страница 6: ...LED ON OK LED 2 red Monitors the light barrier for door opening LED ON OK LED 3 yellow Monitors the emergency stop contact ON OK LED 4 green Indicates signals from key operated switches push buttons o...

Страница 7: ...for the relevant motor must be swapped round see connections The cables to which the capacitor is also connected are the ones that need to be swapped round They determine the direction in which the m...