Chamberlain GmbH
Alfred-Nobel-Straße 4
D-66793 Saarwellingen
www.liftmaster.eu
©2012 Chamberlain GmbH
input Voltage
230–240 V AC, 50 Hz
Max. Pull force
800 N
Watts
400 W
Stand-by power
2.6 W
MOTOR
Type
Motor with capacitor for start and operation
DRiVE MECHANiSM
Drive
Chain with two-piece trolley on steel rail
Door height
adjustable up to 2.3 m or up to 5 m with appropriate extension
Travel rate
100 mm per second
Lighting
turns on when the drive is activated; turns off 2.5 minutes after closing
Door arm
adjustable, trolley unlocking device
SAfETY
Automatic stop
by pressing a button during forward or backward run and obstacle detection
Power recognition
automatic
Overflow protection
Transformer overload protection and low voltage cabling for accessories
Limit switch setting
electronic, semi and fully automatic; optical detection of speed and
door position
DiMENSiONS
Length (overall)
3.1 m
Headroom required
30 mm
Hanging weight
14.5 kg
RECEiVER
Memory Registers
8
Memory Registers
1 – keypad code memory
frequency
433.92 MHz
SPECiAL NOTE
Chamberlain strongly recommends to install
the protector system on all garage door openers!
TECHNiCAL DATA
9A
59
32
5580-2