background image

4

ADDITIONAL PROGRAMMING

The Wireless Commercial Keypad must be put into programming mode prior to any of the programming steps 
below unless otherwise indicated.

Set Temporary PIN

A temporary 4-digit PIN can be programmed to allow access to visitors (maximum of 9 uses). The temporary 
PIN cannot be the same as any previously programmed PIN. The keypad will store up to 10 unique temporary 
PINs. 

Delete Permanent and Temporary PIN

Reset Master Code

Resetting the Master Code will not remove PINs or temporary PINs from memory and will not change the 
frequency and encryption type. After resetting the Master Code, the keypad will not operate any previously 
programmed operators until they are reprogrammed. To reset the Master Code to the factory default (888888):

1.  Unlock and remove the faceplate.
2.   Press and hold the RESET button on the control board for 6 seconds, a long tone sounds indicating the 

Master Code has been reset.

Reset Keypad

Resetting the keypad will erase the Master Code, all permanent PINs, all temporary PINs, and frequency and 
encryption settings. All settings will be set to factory default. After resetting, the keypad will not operate the 
previously programmed operators until they are reprogrammed. To reset the keypad:

1.  Unlock and remove the faceplate.
2.  Press and hold RESET button on the control board for 6 seconds until a long tone sounds then release. 
3.   Press and hold RESET button on the control board for 15 seconds, 3 long tones will sound indicating the 

keypad has been reset.

Lockout Mode

 (Default is ON)

If the keypad receives five consecutive invalid PINs, the keypad will enter lockout mode and will not accept any 
keypad inputs for 30 seconds. After 30 seconds, the keypad will begin accepting new inputs. 

Programming Step

Keystroke Combination

Indicator

1. Enter program mode

*

  (Master Code)  # 

Long tone

2. Set Temporary PIN

05  #  (New temporary 4-digit PIN)  #  (New temporary 
4-digit PIN)  #  Number of uses (9 maximum)  #

Long tone

3. Exit Program Mode

*

  

*

  # 

Keypad backlight will turn off

Programming Step

Keystroke Combination

Indicator

1. Enter program mode

*

  (Master Code)  # 

Long tone

2. Delete PIN

07  #  (4-digit PIN to be deleted)  #  (4-digit PIN to be 
deleted)  #

Long tone

3. Exit Program Mode

*

  

*

  # 

Keypad backlight will turn off

Programming Step

Keystroke Combination

Indicator

1. Enter program mode

*

  (Master Code)  # 

Long tone

2. Set Lockout mode to 

ON

:

02  #  1  #

Long tone

3. Exit Program Mode

*

  

*

  # 

Keypad backlight will turn off

Programming Step

Keystroke Combination

Indicator

1. Enter program mode

*

  (Master Code)  # 

Long tone

2. Set Lockout mode to 

OFF

:

02  #  0  #

Long tone

3. Exit Program Mode

*

  

*

  # 

Keypad backlight will turn off