3
LiftMaster
NOTE:
The Master Code and a PIN need to be set before the gate operator can be programmed. See Basic
Programming, page 2.
KPW5
-
The frequency and encryption are set at the factory.
Proceed to Step 4.
KPW250
-
The frequency and encryption are set at the factory for
LiftMaster S 2.0
(tri-band 310,
315, and 390 MHz) operators.
Proceed to Step 4.
For
LiftMaster S
(315 MHz or 390 MHz), the frequency and encryption need to be set.
Proceed to Step 1.
1. Enter program mode:
*
(Master Code) #
2 Set frequency and encryption (KPW250 only):
• LiftMaster S 315 MHz - Press
03 # 2 #
. A long tone will sound.
• LiftMaster S 390 MHz - Press
03 # 3 #
. A long tone will sound.
• To reset factory default - Press
03 # 1 #
. A long tone will sound.
3. Exit Program Mode:
*
*
#.
4. Press the Learn Button on the operator.
5.
Within 30 seconds-
Enter a valid
4-digit PIN
then press
#
. A long tone will sound.
PROGRAM TO OPERATOR
Linear Multi-Code
KPW250 ONLY
1. Locate the DIP switch sequence on the operator and record it. If DIP switch is in the “up” or “on” (CLOSED)
position place a 1, “down” or “off” (OPEN) position place a 0 in the corresponding box in the chart below.
NOTE:
Leave any unused switch locations blank.
Write the DIP switch 10-digit sequence: ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
2. Enter program mode:
*
(Master Code) #.
A long tone will sound.
3. Set Linear Multi-Code frequency and encryption: Press
03 # 4 #.
A long tone will sound.
4. Enter the DIP Switch sequence (Use ONLY
1
and
0
).
Press
#.
A long tone will sound.
3. Exit Program Mode:
*
*
#.
NOTE:
When entering the DIP Switch sequence 3 beeps will sound if an incorrect number of entries is input.
DIP Switch Sequence
1
2
3
4
5
6
7
8
9
10
UP / ON (CLOSED)
DOWN / OFF (OPEN)
Once an operator has been programmed, enter a valid 4-digit PIN and the # key to activate the operator.