35
DETERMINE AND SET WIRING TYPE (CONTINUED)
Programming
WIRING TYPE
DEVICE
ACTION
STATE
RESPONSE
E2
Momentary
contact to open
with override and
constant pressure
to close. Release
of close button
will cause door to
reverse (roll-back
feature) plus
wiring for sensing
device to reverse.
Compatible with
3-Button Station.
3-Button
Control Station
OPEN button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to the OPEN limit
CLOSE button is
pressed
momentarily
Operator at OPEN limit
Door closes and auto reverses when button is released
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes and auto reverses when button is released
Door stopped during open or close cycle
Door closes and auto reverses when button is released
STOP button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
No change in state
OPEN button is held
(constant pressure)
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to the OPEN limit
CLOSE button is held
(constant pressure)
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes and auto reverses when button is released
Door stopped during open or close cycle
Door closes and auto reverses when button is released
3-Button
Remote Control
Programmed as
OPEN/CLOSE/STOP
OPEN button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to the OPEN limit
CLOSE button is
pressed
momentarily
Operator at OPEN limit
Door closes and auto reverses when button is released
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes and auto reverses when button is released
Door stopped during open or close cycle
Door closes and auto reverses when button is released
STOP button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
No change in state
Single Button
Remote Control
Button is pressed
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
No change in state
Single Button
Control Station
(Wired)
Button is pressed:
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
No change in state
Door stopped during the open cycle
No change in state
Door stopped during the close cycle
No change in state
myQ
Door image is pressed:
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
No change in state