26
NOTE:
If the photoelectric sensor gets blocked while the gate is
closing, it will stop and reopen. The gate will remain open until
the obstruction is cleared.
Contact your local dealer for more information about photoelectric sensors.
Safety Non-Contact Sensor
Entrapment Non-Contact Sensor
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Locate entrapment protection devices to protect in BOTH the
open and close gate cycles.
• Locate entrapment protection devices to protect between
moving gate and RIGID objects, such as posts or walls.
Non-Contact Sensors (12 Vdc Photoelectric Sensors)
NOTE:
Property owners are obligated to test photoelectric sensors
monthly.
See Accessories for part number.
It is best to use Failsafe Photoelectric Sensors for
this safety option.
Failsafe Photoelectric Sensors:
If a failsafe
photoelectric sensor is not working or loses power
or photoelectric sensor is blocked, then the
photoelectric sensors will stop ALL gate operation.
WIRING
ENTRAPMENT PROTECTION DEVICES