The operators have provisions for manually operating the door in 
case of emergency or power failure. Refer to the appropriate 
instructions for your model operator.

MODEL MT/BMT

MODEL MH

These operators are equipped with a manual hoist. An electrical 
interlock will disable the electrical controls when the hoist is used. To 
operate the hoist:

1.  Pull the disconnect chain (sash chain) to engage the hoist 

mechanism. The disconnect chain may be locked in position by 
slipping the end through the keyhole of the chain retaining bracket 
mounted on the wall.

2.  Operate the door in the desired direction by pulling on one side or 

the other of the continuous loop hoist chain.

3.  The disconnect chain must be released from the chain retaining 

bracket before the door will operate again electrically.

Electrical Interlock with Hoist for Model MH

Chain Retaining Bracket
(with pad locking provisions)

NO

E

C

I

T

To prevent possible SERIOUS INJURY or DEATH from a falling 
door or arm:
•  DO NOT stand under the door arm when pulling the emergency 

release.

•  If possible, use emergency release handle to disengage trolley 

ONLY when door is CLOSED. Weak or broken springs or 
unbalanced door could result in an open door falling rapidly and/
or unexpectedly.

•  NEVER use emergency release handle unless doorway is clear of 

persons and obstructions.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

CAUTION

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

Emergency
Disconnect

Door

Emergency
Release Handle

Emergency
Disconnect

Emergency
Disconnect

Door Arm

Door 
Arm

Pull emergency 
release handle 
straight down. 
Emergency 
disconnect will 
open.

Lift free end of door 
arm to trolley. Pull 
emergency handle 
to allow arm to 
engage roll pin. 
Release handle. 
Emergency 
disconnect will 
close.

TO DISCONNECT DOOR FROM OPENER

TO RECONNECT DOOR ARM TO TROLLEY

M A N U A L   D I S C O N N E C T   ( M O D E L S   M T / B M T   &   M H )

5

Содержание BMT 5011E

Страница 1: ...MEDIUM DUTY LOGIC USER S GUIDE Radio Receiver Built on Board Installation Date www liftmaster com Contact Information 315MHz MJ 5011E BMT 5011E MT 5011E MHS 5011E MH 5011E MGJ 5011E ...

Страница 2: ...ADVERTENCIA A B C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE Factory Default C2 WIRING TYPE WITH MONITORED SAFETY DEVICE Momentary contact to open and stop with constant pressure to close Open override that reverses when closing by any opening device Wiring for safety device to reverse NOTE The operator will automatically convert to B2 wiring option D when Monitored Safety Device is installed Se...

Страница 3: ...evice Wiring for safety device to reverse NOTE The operator will automatically convert to B2 wiring when Monitored Safety Device is installed See accessories page for Monitored Safety Devices Timer to Close TTC feature available Start with operator in factory default C2 mode Press and hold the LEARN and CLOSE buttons until the LED goes out approximately 3 seconds TO PROGRAM TTC LED AUX ANT R27 L5 ...

Страница 4: ...TROL STATION NOTE The feature will use 3 of the 20 memory channels in the operator TO PROGRAM 1 Press and hold the LEARN button LED will light 2 Press the desired button on the logic board OPEN CLOSE or STOP Release both buttons 3 Press and hold the desired button of the remote control until LED flashes rapidly then release 4 Repeat steps 1 through 3 to program additional buttons TTC LED AUX ANT R...

Страница 5: ... for Model MH Chain Retaining Bracket with pad locking provisions NO E C I T To prevent possible SERIOUS INJURY or DEATH from a falling door or arm DO NOT stand under the door arm when pulling the emergency release If possible use emergency release handle to disengage trolley ONLY when door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unex...

Страница 6: ...t sash chain for push up pull down operation This chain can be found on the hoist side of the operator See Manual Disconnect Model MJ MGJ for instructions 2 A hoist engagement sash chain for manual hoist operation This chain can be found on the clutch side of the operator See Manual Disconnect Model MH for instructions When operator is disconnected by the manual operation chain hoist and electrica...

Страница 7: ...n direction 2 Press STOP button The door should stop 3 Press CLOSE button The door should move in the close direction 4 Release CLOSE button Door should stop if in C2 mode The door should continue closing if in B2 mode 5 Press STOP button The door should stop TEST LIMIT ADJUSTMENT 1 Press OPEN button The door should open 2 Allow the door to fully open 3 Press CLOSE button The door should close 4 A...

Страница 8: ...rator still does not operate properly contact your installing dealer RADIO FUNCTIONALITY NO RESPONSE Remote control is not programmed See PROGRAMMING REMOTE CONTROLS section Low battery Replace battery REMOTE CANNOT BE PROGRAMMED Low battery Replace battery POOR RANGE Low battery Replace battery Possible radio interference Contact your installing dealer 8 Every 3 months or 5 000 cycles repeat all ...

Страница 9: ...9 O P E R AT O R N O T E S ...

Страница 10: ...10 O P E R AT O R N O T E S ...

Страница 11: ...O P E R AT O R N O T E S 11 ...

Страница 12: ...ot be used in place of hardwired controls 2 Button Control Station Steel enclosure OPEN TO PRESS RING 2 Strand 22 AWG Wire 500 Color coded white and white black 7 Conductor 20 AWG Wire 500 Recommended for control wiring Commercial Protector System Provides protection on doors up to 45 wide NEMA 4 rated 21 2LM 65 7WIREL CPS LN4 External Antenna The external antenna can be used to increase the radio...

Отзывы: