2 of 40 

Doc 6001343 (01-20299) 

Rev B 

SAFETY SUMMARY 

It is important for everyone involved in the installation and operation of the LiftMaster model BG 3100-X1 
Barrier Gate Operator to read the following warnings. 

WARNING! 

••••

  A vehicle gate is a large, heavy object that is moved by an electric motor.  A moving 

gate can cause serious injury or death!  The safety and well-being of others depends 
on the installation of a safe system. 

••••

  Improper installation of a gate operator can result in a dangerous system. 

••••

  Gate operators can present serious hazards to persons in the immediate area when 

not controlled in a safe manner.  Choose one or more controls which together will 
allow complete control of the gate.  Most importantly, the gate must be able to be 
stopped at all times in case of emergency, and the emergency control should be 
conveniently located, clearly marked and visible. 

••••

  All controls must be kept out of reach of small children.  Serious injury or death can 

result from children playing with the controls. 

••••

  All controls should be located so the person operating them can see the full area of 

gate movement. 

••••

  Gate operators and associated control equipment should be installed by qualified 

professional installers who should observe the following safe installation procedures: 

  1.  Power should always be disconnected whenever installing, wiring or servicing a 

gate operator.  Moving chains and belts in gate operators can catch clothing or 
fingers and cause severe injury. 

  2.  Installation of wiring should comply with all local building and electrical codes. 
  3.  All manual gate locks should be disabled to avoid damage to the gate or gate 

operator should the lock become engaged after the operator is installed. 

  4.  All operator controls and safety equipment should be tested at the conclusion of 

installation to be sure they are functioning properly. 

  5.  The operation of the gate controls and safety equipment should be reviewed with 

the owner and/or end user of the automated gate system.  They should also be 
informed of the need to maintain control and safety equipment on a regular basis.  
Safety equipment should be checked monthly to ensure it is working properly.  All 
installation manuals and safety information should be left with the owner. 

  6.  Moving gates have pinch points and entrapment zones which can be extremely 

dangerous to pedestrians, especially small children. 

Содержание BG 3100-X1

Страница 1: ...S INSTALLATION AND OPERATION INSTRUCTIONS INSTALLATION AND OPERATION INSTRUCTIONS INSTALLATION AND OPERATION INSTRUCTIONS FOR THE FOR THE FOR THE FOR THE MODEL MODEL MODEL MODEL BG 3100 BG 3100 BG 310...

Страница 2: ...9 G GATE ARM INSTALLATION 9 H GATE ARM ADJUSTMENT FOR TYPICAL INSTALLATION 11 I LIMIT CAMS 11 J GATE SENSITIVITY ADJUSTMENTS 11 K POWER FAIL OPERATION OPTION CONNECTION 13 L CONNECTING INPUT WIRING 1...

Страница 3: ...Figure 5 Gate Direction Power Fail Option Switch Location 8 Figure 6 Manual Controls Location and Use 9 Figure 7 Extension Arm Fabrication 9 Figure 8 Gate Arm Installation 10 Figure 9 Gate Arm Adjustm...

Страница 4: ...in the event of a fault or warning condition A call can be made to any modem or pager and will include system ID number and fault condition code 12 button keypad and 7 segment display to facilitate p...

Страница 5: ...area of gate movement Gate operators and associated control equipment should be installed by qualified professional installers who should observe the following safe installation procedures 1 Power sho...

Страница 6: ...hould try to discharge any static before handling the circuit boards WARNING Damage caused by static discharge and lightning is not covered by warranty 4 PROVIDE POWER FROM A DEDICATED SOURCE The outl...

Страница 7: ...rap and Tandem gates see Installation and Operation of the SL 1000 SW 2000 BG 3000 and BG 3100 X1 Master Slave Configurations Document Number 6001376 1 Always install the gate operator on the inside o...

Страница 8: ...8 in diameter L bolts X 6 are recommended 3 The pad should be level and about 4 above grade to prevent water entrance Allow concrete to set at least two days before installing gate 4 Be sure to provid...

Страница 9: ...n Option is about 12 x 6 x 32 4 Wiring should be 16 24 AWG stranded or 18 24 AWG solid NOTE Optional LiftMaster supplied loop detector add on boards are available both pre installed and for installati...

Страница 10: ...quare and that the gate operator access door faces away from the driveway see Figure 1 2 Slightly loosen the mounting screws of the control box clear plastic cover Slide the cover out 3 Swing the cont...

Страница 11: ...s off set switch S1 to the left if the cabinet access door faces away from the driveway typical installation or to the right if the access door faces the driveway restricted installation If the system...

Страница 12: ...rminal the gate is prevented from moving and no command will affect the gate G GATE ARM INSTALLATION A sixteen foot wishbone arm is supplied with every BG 3100 X1 If a longer arm is desired an extensi...

Страница 13: ...and arm clamps to the hub flanges using hardware provided Figure 8 2 Bolt counterweights to ends of arm clamps using hardware provided Figure 8 3 If extension arm is required sandwich the extension ar...

Страница 14: ...eak motor current When the gate encounters an obstruction the gate operator sense the change in motor current and stops or reverses the gate Three sensitivity adjustments are factory set for most inst...

Страница 15: ...Wait 1 to 2 seconds then lightly tug against the edge of the gate to simulate an obstacle 3 If the gate does not stop or back up reclose the gate and adjust the pot slightly counterclockwise 4 Repeat...

Страница 16: ...ption Because the battery may not be fully charged at the time of the test we strongly suggest moving the gate only one foot when performing the power fail test 1 Set Power Fail switch S2 to the same...

Страница 17: ...the next page 1 Wire all external control devices to their connections on the control board as shown See Appendix A for details on how each control input affects the gate operator 2 Master Slave Inst...

Страница 18: ...either directly or by telephone For complete programming instructions refer to the enclosed manual SL 1000 SW 2000 BG 3000 and BG 3100 X1 Programming 73 Bd Doc No 6001312 To access programming mode en...

Страница 19: ...no belt slippage when the gate moves or stops 4 Master Slave system only Both gates open and close at the same time Bi Parting gates only 4 Gate Sensitivity 1 Left Right Reverse sensitivity Apply a bu...

Страница 20: ...he vehicle drives off the Interrupt Loop set Gate Type Swing and disable the ATG 2 If you want the gate to stop when a vehicle drives onto the Interrupt Loop and to close when the vehicle drives off t...

Страница 21: ...ure with two wing nuts 2 Swing hinged control box into cabinet and secure in place with hardware provided 3 Install clear cover on control box and secure with the four screws provided 4 Make sure that...

Страница 22: ...until AC power is restored When AC power is restored the battery is charged up to its full potential then is continuously trickle charged Recharging takes from one to five hours depending on the weig...

Страница 23: ...and 3 white wire on the Control Board must measure 100 VAC to 130 VAC CAUTION HIGH VOLTAGE Measure with care Fault Causes Refer to the end of troubleshooting section 1 OPERATOR IS DEAD When the unit p...

Страница 24: ...STOPS WHILE OPENING OR REVERSES WHILE CLOSING A Fault has occurred 8 OPENING GATE STOPS WHEN A VEHICLE APPROACHES THE GATE Gate Type is set to Swing causing the Interrupt loop to stop the gate 9 GATE...

Страница 25: ...nuously activated stuck 2 The gate was not on the open limit switch when the power went out 3 Reclose Timer is disabled 18 GATE DOES NOT MOVE AFTER POWER OUTAGE 1 Bad Power Fail Option battery 2 Miswi...

Страница 26: ...ate Type and ATG settings 2 Bad loop sensor or loop detector 3 Bad connection between the loop sensor loop detector and the Control Board 25 MAGLOCK DOES NOT WORK 1 Bad connection between Maglock its...

Страница 27: ...me by the following if Max Retry Count is set to 0 Fire command Manual commands Open Close Stop All other commands must wait 60 seconds to clear these faults Faults 4 5 and 6 may be cleared at any tim...

Страница 28: ...ance is essential PREVENTIVE MAINTENANCE TASKS 1 Gate must swing freely without any impediment Tighten set screws if loose Check hub grease if necessary 2 Limit switches contacts must bounce back rapi...

Страница 29: ...a record of the maintenance schedule Write the inspection date in the left hand box and check the boxes across as you perform you maintenance procedures MAINTENANCE SCHEDULE TABLE Date Gate Arm Limit...

Страница 30: ...efully 1 REPLACING AND ADJUSTING LIMIT CAMS IN A TYPICAL INSTALLATION Figure 13 Setting Limit Cams for Typical Installation 1 Make sure that switch S1 is set to the Left position 2 Turn on gate operat...

Страница 31: ...ose loosen the locking screw on the right limit cam and turn the cam clockwise until it just barely closes the limit switch 5 Tighten the right limit cam locking screw 6 Using manual OPEN and STOP mov...

Страница 32: ...PERATION REFERENCE CONTROLS INDICATORS INPUTS AND ADJUSTMENTS For control and indicator locations refer to the figure below For detailed explanations of the Gate Operator s various controls indicators...

Страница 33: ...using the phone line TIMER Indicates the Reclose Timer is running Timer is set at pot R94 FAULT Indicates a fault in the system See Fault List in Part 5 Troubleshooting and Maintenance MAX RUN TIME I...

Страница 34: ...hen Fire is deactivated gate closes immediately If Reclose Timer is enabled when Fire is deactivated the Reclose Timer starts Fire overrides all commands but Manual Stop EXIT LOOP SHADOW LOOP DETECTOR...

Страница 35: ...n tries to resume The gate will retry up to twice before faulting out WARNING TB8 WARNING OUT Relay contacts close depending on the programmed setting of the warning PHONE LINE J9 PHONE LINE Terminals...

Страница 36: ...Rev B Doc 6001343 01 20299 33 of 40 NC and COM inputs close a circuit security camera camcorder light etc when the Close Limit switch is deactivated when gate is not fully closed...

Страница 37: ...sense adjustments left and right where other gate operators have only one This allows greater flexibility of installation For instance you can install a gate on an incline and not worry about sacrifi...

Страница 38: ...Failure to observe this will damage both controller board 2 Do not parallel wire the MAGLOCK terminals Auxiliary device circuits may be damaged if separate auxiliary devices are used with each board...

Страница 39: ...36 of 40 Doc 6001343 01 20299 Rev B APPENDIX C MODEL BG 3100 X1 PARTS LIST 1343F9 1 2 4 28 30 14 8 15 29 28 4 29 30 17 9 16 11 27 10 31 7 25 26 18 19 20 21 22 23 24 5b 5a 6 13 12 3...

Страница 40: ...embly Controls lever arm limits 15 Limit Switch Cable Assembly Connects limit switch to control board 16 Limit Switch Stops motor when gate reaches limit 17 Limit Cam Activates limit switch 18 Limit S...

Страница 41: ...s the gate has reached its open or close limit causing the gate to stop There are two limit switches open and close Limit cam The excursion of this object corresponds to the gate traveling distance an...

Страница 42: ...customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative de...

Страница 43: ...aster The software and firmware included in the LiftMaster product as they relate to this documentation are also protected by copyright and contain information proprietary to LiftMaster FOR TECHNICAL...