Chamberlain 912GA Скачать руководство пользователя страница 2

2

CYCLES/DAY USING 10W SOLAR PANEL

Gate Configuration

Single Gate < 300 lbs.

Single Gate > 300 lbs. or

Dual Gate < 300 lbs. Each

Dual Gate > 300 lbs. Each

Zone 1

52

26

17

Zone 2

32

16

11

Zone 3

13

6

4

1

1

1

2

3

REGIONAL INSTALLATION RECOMMENDATIONS

The solar map (above) and cycles/day ratings are approximations and do not account for installed accessories that draw additional battery power.
Ratings vary based on gate construction and installation. They are also shown for using a single 10W solar panel in conjunction with two 12 Volt 7.0
AH batteries. Ratings will improve by adding additional 10W solar panels. If required, up to three 10W panels (30W total) can be wired in parallel to
increase the number of cycles per day.

NOTE:

The solar panel(s) recommendation is based upon the average solar radiation and the temperature effects on batteries in the given regions.

Local geography and weather conditions may require additional solar panels. Solar panels cannot be installed in areas that experience heavy fog or
lake effect rain and snow.

PREPARATION

Selec

t

 Si

t

e fo

r

 Sola

r

 Panel(s)

The sola

r

 panel(s) mus

t

 be loca

t

ed in an open a

r

ea clea

r

 of obs

tr

uc

t

ions and shading fo

r

 

t

he en

t

i

r

e day.

NOTE: 

The solar panel(s) comes with a 10' cable. If a location near the control box cannot be found, an additional cable will be required.

(Model 917GA). Northern climates (where temperatures reach -4°F(-20°C) and below) are poor candidates for battery powered gate operator
applications. This also makes them poor candidates for solar power. Call technical support for more information.

NOT RECOMMENDED

Содержание 912GA

Страница 1: ...h a single battery A second battery and battery cable can be obtained by purchasing the 922GA battery kit 10WATTSOLARPANEL MODEL912GA Cable Cable Ties 3 Compass Washered nuts 2 Bolt M6 x1 2 Screw 14 x1 2 Solar Panel Solar Panel Mounting Bracket Solar Panel Facing South Control Box To reduce the risk of fire and the risk of SEVERE INJURY or DEATH to persons disconnect electrical power to operator B...

Страница 2: ...ase the number of cycles per day NOTE The solar panel s recommendation is based upon the average solar radiation and the temperature effects on batteries in the given regions Local geography and weather conditions may require additional solar panels Solar panels cannot be installed in areas that experience heavy fog or lake effect rain and snow PREPARATION Select Site for Solar Panel s The solar p...

Страница 3: ...er months when the sun sits lower in the sky TIP Wire runs should be kept as short as possible The solar panel s can be located up to 100 from the operator using 16 AWG wire in any direction including elevating it If a suitable site cannot be found for the panel s please contact Chamberlain to determine if solar is appropriate for this installation Winter Sun Height South Up to 15 Summer Sun Heigh...

Страница 4: ...nd align both bolts Secure Solar Panel s to Solar Bracket Secure solar panel s to solar bracket using two washered nuts Solar Panel Washered Nut Solar Bracket Washered Nut Mount Solar Panel s Assembly Secure solar panel s assembly to mounting surface using appropriate hardware Position Solar Bracket Position solar bracket on mounting surface Mark and drill holes NOTE Solar panel s MUST be installe...

Страница 5: ...ter wires must be removed before the solar panel wires can be connected Connect the AC PWR SOLAR connector to the control board With the batteries still disconnected the control board should power up if the solar panel is correctly installed and the sun is shining This is observed by the DIAGNOSTIC LED blinking NOTE If the sky is too overcast to allow the solar panel to power up the system the pan...

Страница 6: ... run Make sure that no cables or other obstructions are preventing the gate s from moving freely Operator works fine for several weeks or months but then batteries die 1 Batteries not being charged Make sure the solar panel is facing south and free of all obstructions throughout the day Make sure the panel is clean of debris and connected correctly to the control board 2 Operator is over used Cons...

Страница 7: ...7 ...

Страница 8: ... 2008 The Chamberlain Group Inc 01 33936B All Rights Reserved ...

Отзывы: