background image

 

  

 
 

___________________________________________________________________________________________________ 
I-ARRI-01.doc 

  

 Issue 03                        25

th

 April 2016 

 

 

 

 

 

   1

 

 

 
 
 
 

      IOM 

– 

ARRAN LED FLOODLIGHT (IND) 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

0.0  Specification

 

 

Type Of Protection   

N/A 

Standards 

EN 60598-1,  

Area Classification 

Non- Hazardous  

Ambient  

-50°C to +55ºC

 

Ingress Protection 

IP66 to EN 60529 

Photobiological safety of 
Lamps and Lamp Systems 

Risk Group 2 LED product to IEC 62471 
 

Vision Advisory Claim  

WARNING: Do not look at exposed led in operation especially with optical instruments. Eye 
injury can result.  

CE Mark 
 

The  CE  marking  of  this  product  applies  to  "The  Electrical  Equipment  (Safety)  Regulations 
2006",  "The  Electromagnetic  Compatibility  Regulations  2004

",  the  “Waste  Electrical  and 

Electronic Equipment Regulations 2006”.  [This legislation is the equivalent in UK law of EU 
directives 2014/35/EU, 2014/30/EU, 2012/19/EU respectively]. 
 

M Poutney    Technical Manager 

 

 

Arran LED Floodlight Luminaire  

Industrial 

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 

Important: 

Please read these instructions carefully before installing or maintaining this equipment. 

Good electrical practices should be followed at all times and this data should be used as a guide only. 

Содержание Arran

Страница 1: ...with optical instruments Eye injury can result CE Mark The CE marking of this product applies to The Electrical Equipment Safety Regulations 2006 The Electromagnetic Compatibility Regulations 2004 the...

Страница 2: ...be stored in cool dry conditions preventing ingress of moisture and condensation 3 0 Installation and Safety 3 1 General There is no health hazards associated with this product whilst in normal use Ho...

Страница 3: ...supplied with suitability for looping Where looping is used the maximum current is 16A Terminals are accessed by removing the access door cover on the back of the luminaire Maximum cable temperature r...

Страница 4: ...must be done by a competent electrician with the luminaire isolated and if carried out with the luminaire in place under a permit to work Fault finding is by substitution with known good components 4...

Страница 5: ...with the locations of the holes on the reflector and retain the screws Place the reflector into position lining up the holes in the reflector with the holes on the lens housing Reinstall the removed 7...

Страница 6: ...___________________________________________________________________________________________________ I ARRI 01 doc Issue 03 25 th April 2016 6 IOM ARRAN LED FLOODLIGHT IND...

Страница 7: ...sorgung der elektrischen und elektronischen Ger te Systeme 2011 65 EU RoHS II Directive On behalf of the Chalmit I declare that on the date the equipment accompanied by this declaration is placed on t...

Отзывы: