background image

 

  

 
 

___________________________________________________________________________________________________ 
I-ARRI-01.doc 

  

 Issue 03                        25

th

 April 2016 

 

 

 

 

 

   5

 

 

 
 
 
 

      IOM 

– 

ARRAN LED FLOODLIGHT (IND) 

 

Directions for Installation of Accessories 

Note: Reflector and Guard cannot be used simultaneously. 

 
WARNING: Ensure the supply circuit is off before starting installation. 

 
To  install  reflector,  carefully  remove  the  7  screws  provided  in  housing  that  align  with  the  locations  of  the  ho les  on  the 
reflector  and  retain  the  screws.  Place  the  reflector into position, lining up the holes in the reflector with the holes on th e 
lens housing. Reinstall the removed 7 screws into the existing hole location, and tighten to secure. CAUTION  - All screws 
must be properly installed to maintain the integrity of the lens gasket seal. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

 

 
 
 

To install lens assembly guard, verify that the luminaire is completely assembled.  Install lens guard on lens assembly by 
hooking the gu

ard’s end tabs under the luminaire housing's end tabs. Verify a tight attachment. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SCREWS 

HOOK WIRE 
END TABS 
UNDER 
HOUSING 
END TABS 

Содержание Arran

Страница 1: ...with optical instruments Eye injury can result CE Mark The CE marking of this product applies to The Electrical Equipment Safety Regulations 2006 The Electromagnetic Compatibility Regulations 2004 the...

Страница 2: ...be stored in cool dry conditions preventing ingress of moisture and condensation 3 0 Installation and Safety 3 1 General There is no health hazards associated with this product whilst in normal use Ho...

Страница 3: ...supplied with suitability for looping Where looping is used the maximum current is 16A Terminals are accessed by removing the access door cover on the back of the luminaire Maximum cable temperature r...

Страница 4: ...must be done by a competent electrician with the luminaire isolated and if carried out with the luminaire in place under a permit to work Fault finding is by substitution with known good components 4...

Страница 5: ...with the locations of the holes on the reflector and retain the screws Place the reflector into position lining up the holes in the reflector with the holes on the lens housing Reinstall the removed 7...

Страница 6: ...___________________________________________________________________________________________________ I ARRI 01 doc Issue 03 25 th April 2016 6 IOM ARRAN LED FLOODLIGHT IND...

Страница 7: ...sorgung der elektrischen und elektronischen Ger te Systeme 2011 65 EU RoHS II Directive On behalf of the Chalmit I declare that on the date the equipment accompanied by this declaration is placed on t...