Challenger SL104C Скачать руководство пользователя страница 3

3

1. Turn off the power at the main fuse box in your home(see Fig. 3).

2. Fix metal bracket on the wall with 2 Wood Screws (not included).

3. Fix halogen lamp to metal bracket with attached hardware.

4. Strip sheath and insulation of cable. Let conductors expose

approximate 6 mm.

5. Open cover of connection box.

6. Lead power wire through attached grommet.

LOCATION SELECTION

Selecting A Location

1. When mounted at the recommended height of 2M, the detection pattern extends 12M.

(see Fig. 5)

Fig. 4

Fig. 3

Fig. 5

2.0M

0

3

6

9

12M

TOP VI EW

SIDE VI EW

CAUTION:

PLEASE FOLLOW AC POWER CONNECTION

LABEL MARKINGS.

WRONG POWER CONNECTION WILL

DESTROY THIS SENSOR UNIT.

9
6
3
0

110

°

3
6
9

7. Connect wire to terminals as Fig. 4

8. Fix power cable (use plate. Ref K).

NOTE: 1. If more range is required, try

pointing the motion sensor slightly

upward, so that the 3rd Level of

vision can monitor an area above

your head.

2. Try to keep the quartz light as far

away as possible from the motion

sensor, as heat from the light may

confuse the motion sensor.

WARNING !! THIS UNIT MUST BE EARTHED

Connection box lid

SL104 CONNECTION DIAGRAM

LAMP

N

L

Blue wire

Green & yellow wire

230v ac supply cable

230v ac supply cable

Brown wire

Cable clamp

Connection box

*

 THIS FITTING MUST BE EARTHED

Pre wired

connections

to lamp &

sensor

9.  Close cover of connection box.

Содержание SL104C

Страница 1: ...ION CONTROL Fig 1 1 TIME Adjusts the infrared motion sensor s shut off time Light will remain on for the setting time interval after last motion is detected 2 LUX The light sensitivity adjustment allo...

Страница 2: ...gin please verify the contents of this package It should contain the following parts LIST PARTS NAME QUANTITY LIST PARTS NAME QUANTITY A Mounting Bracket 1 H Rubber Washer 1 B Halogen Light 1 I Termin...

Страница 3: ...AC POWER CONNECTION LABEL MARKINGS WRONG POWER CONNECTION WILL DESTROY THIS SENSOR UNIT 9 6 3 0 110 3 6 9 7 Connect wire to terminals as Fig 4 8 Fix power cable use plate Ref K NOTE 1 If more range is...

Страница 4: ...VE LAMPS OR NEAR AIR VENTS MORE SENSITIVE TO MOVEMENT ACROSS FIELD THAN INTO FIELD POSITIONSENSOR EXACTLYLEVEL FROM SIDE TO SIDE AVOID REFLECTED LIGHT FROM BRIGHTSURFACES DON T EXPOSE TO RAIN OR ROOFR...

Страница 5: ...g to motion objects when the ambient light level is lower than the detector s setting on LUX control It will remain On when detector is activated as long as the setting on Time control NOTE When the L...

Страница 6: ...Detector clicks butdoes not operate Check lamps are not broken Check lamps tight in lampholders 3 Lights go on and off quickly Ensure light and heat are not being reflected back onto the detector Chec...

Страница 7: ...instructions have been carefully checked prior to publication However no responsibility can be accepted by Challenger for any misinterpretation of these instructions RoHS CHALLENGER SECURITY PRODUCTS...

Отзывы: