Fig. 9
OPERATION
Control Panel
9
MODE button
Selects the appropriate operating
mode. Each time you press the button,
a mode is selected in a sequence that
goes from COOL, FAN and DRY .The
mode indicator light illuminates under
the different mode setting.
NOTE: On above modes, the unit
operates the auto fan speed
automatically. You can set fan speed
only by the remote control on
COOL and FAN modes.
Used to adjust (increasing/decreasing)
temperature settings in 1°C/2°F(or 1°F)
increments in a range of 17°C/62°F to
30°C/88°F (or 86°F).
NOTE: The control is capable of
displaying temperature in degrees
Fahrenheit or degrees Celsius. To
convert from one to the other, press
and hold the Up and Down buttons
at the same time for 3 seconds.
Power button
Turn the unit on/off.
Power
indicator light
Timer mode indicator
light (set only by
remote control)
Up (+) and Down (-) buttons
LED display
Shows the set temperature while on cool
mode. While on DRY and FAN modes, it
shows the room temperature.
Shows Error codes:
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E4-Display panel communication error.
EC-Refrigerant leakage detection
malfunction(on some models).
Shows protection code:
P1-Bottom tray is full--Connect the drain
hose and drain the collected water away.
If protection repeats,call for service.
Note: When one of the above malfunctions
occurs, turn off the unit, and check for any
obstructions. Restart the unit, if the
malfunction is still present, turn off the unit
and unplug the power cord. Contact the
manufacturer or its service agents or a
similar qualified person for service.
Содержание MPPHA-05CRN1-QB6
Страница 1: ...INSTRUCTION MANUAL 5000 BTU LOCAL AIR CONDITIONER...
Страница 20: ...19...