User's manual
7
Domestic hot water regulation
This is on when the appliance is on. The temperature of the domestic
hot water can be adjusted between 40 and 65°C using setting button
9
.
The selected setpoint value fl ashes for a few seconds then stays lit on
the vertical level indicator.
COMFORT function
The comfort level can be increased for the distribution of domestic
hot water using the COMFORT function. The temperature of the
secondary exchanger is maintained during periods of inactivity, in
order to reduce the waiting time for hot water when drawing off .
This function is activated by pressing the COMFORT key
5
.
The plate heat exchanger's temperature is maintained 24 hours a day,
every day.
Boiler shutdown
Setting to standby
To shut down operation of the Hybrid System, press the
ON/OFF key
2
.
Hybrid System complete shutdown
To shut the system down completely, cut the main supply to the boiler
and the heat pump using the external electrical switches.
The display is switched off . Close the boiler's gas tap.
IMPORTANT
When the system is set to standby or shut down
completely, anti-freeze protection no longer operates
for the boiler, heat pump or heating installation.
INFO key
Press the
key to access the data indicated in the table below.
Press the
key to move from one line to another.
Press the Esc key to exit the menu.
Sanitaire
Cycle comfort en cours
List of information displayed
Outdoor temperature
(°C)
- only with external sensor connected (option)
Indoor temperature
(°C)
Domestic hot water fl ow rate
(l/min)
Heating setpoint temperature
(°C)
Domestic hot water setpoint temperature
(°C)
Months remaining before the next maintenance
Telephone and name for technical assistance
(displayed if data entered in parameters 890 - 891)
Domestic hot water comfort setpoint
(°C)
SRA
function
Activated
or
deactivated
if the symbol is lit on the display
Storage temperature
(°C)
only for boiler with storage tank
Domestic hot water
Comfort cycle in progress