103
GB
MENU
SUB-MENU
P
ARAMETER
DESCRIPTION
RANGE
NOTE
8
1
2
No. of fl ame cutouts (no. x 10)
8
1
3
No. of ignition cycles (no. x 10)
8
1
4
Average heat request duration
8
1
5
Number of fi lling cycles
8
2
Boiler
8
2
0
Burner modulation level
8
2
1
Fan status
ON - OFF
8
2
2
Fan speed x 100 RPM
8
2
3
Pump speed level
0. OFF
1. Low speed
2. High speed
8
2
4
Diverter valve position
0. Domestic hot water
1. Heating
8
2
5
Domestic hot water fl ow rate l/min
8
2
6
Flue gas pressure switch status
0. Open
1. Closed
8
2
7
% pump modulation
8
2
8
Instant power
8
3
Boiler temperature
8
3
0
Set heating temperature
8
3
1
Heating fl ow temperature
8
3
2
Heating return temperature
8
3
3
Recorded domestic hot water temperature
8
3
4
Flue gas temperature
8
3
5
Outdoor temperature
8
4
Solar heating system & Indirect cylinder
8
4
0
Recorded storage tank temperature